Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun SPARC[tm] Enterprise T5140 Server: Hardware Specifications

Processor
Number Two UltraSPARC T2 Plus multicore processors
Architecture SPARC V9 architecture, ECC protected
CPUs 1.2GHz 4-Core (32 ×2 for a total of 64 concurrent threads)
1.2GHz 6-Core (48 ×2 for a total of 96 concurrent threads)
1.2GHz 8-Core (64 ×2 for a total of 128 concurrent threads)
1.4GHz 8-Core (64 ×2 for a total of 128 concurrent threads)
Cache memory 4MB Level 2
Main Memory
Capacities Total DIMM slots: 16
DIMM type: FBDIMM
DIMM size: 1GB, 2GB, 4GB or 8GB
Maximum capacity: 128GB (16 × 8GB)
Standard Integrated Interfaces
Network 4 × 10/100/1000 Mbps autonegotiating ports
Note: 10-Gb Ethernet ports are available by adding XAUI cards to the I/O expansion slots. For each XAUI card added, one onboard 1Gb ethernet port is disabled.
Network Management One dedicated 10/100Base-T RJ-45 port Ethernet port
Serial Management One dedicated RJ-45 port
Remote Management Onboard system controller, running Integrated Lights Out Manager (ILOM) 2.0 with two command sets:
  • ILOM
  • ALOM CMT compatibility shell
Both command sets are available through the RJ-45 serial and 10/100Mbps ethernet interfaces.
Serial One DB-9 connector
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
PCI Expansion Slots
  • 3 low-profile PCI-Express slots.
  • Slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards.
Slot # Physical Electrical
0 x8 x8
1 x8 x8
2 x16 x8
Internal Mass Storage
Disks
  • All PTO standard configurations ship with 4 disk backplanes and cannot be changed later.
  • ATO configurations provide a 4 disk or 8 disk backplane option as a selectable item.
  • The maximum disk capacity depends on which backplane is selected, and cannot be changed later. <.li>
    • Up to 8 73GB (10K or 15K RPM), 146GB 10K RPM, and 300GB, 10K RPM SAS 2.5 inch form factor disk drives
Notes:
Integrated hard drive controller supports RAID 0 and RAID 1.
Solid State Drives
  • Up to 4 32GB solid state drives
DVD-ROM 1 slimline DVD-Writer/CD-Writer
Power Supplies
2 × 720 Watt, hot-swappable, N+1 redundant power supply units (PSU)
Environment
Input Voltage 100 - 240 VAC, 50-60Hz
Input Current 8.3 - 7.2 A @ 100-120 VAC (max)
4.3 - 3.6 A @ 200-240 VAC (max)
Note: The maximum operating input values are based on P / (V *0.95), where P=maximum input power, V=input voltage. You can use this equation to calculate the maximum operating input current for your specific input voltage.
Input Power 822 W (max)
Heat Output 2,804 BTU/hr (max)
Temperature

Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)

Note: Above 900m (3000 ft), decrease maximum temperature as altitude increase, 1° C/300m (1.6° F/1000ft)

Humidity Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) maximum wet bulb
Nonoperating: 93% relative humidity noncondensing, 35° C (95° F) maximum wet bulb
Altitude Operating: up to 3000m (10000 ft.)
Nonoperating: up to 12000m (40000 ft.)
Vibration Operating: 0.15G (z-axis), 0.10G (x,y axes) 5-500Hz swept sine
Nonoperating: 0.5G (z-axis), 0.25G (x,y axes) 5-500Hz swept sine
Shock Operating: 3G, 11ms half-sine
Nonoperating: 1-inch roll-off free fall, front-to-back rolling direction, 25mm threshold height at 0.75 m/s impact velocity
Sound Power Level
LwAd (1 B = 10dB)
Operating: 7.3 B
Idling: 7.3 B
Sound Pressure Level
LpAm (bystander positions)
Operating: 62 dB
Idling: 62 dB
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:Y
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1,2 CFR21 part 1040, CNS14336, GB4943
RFI/EMI EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ3548 Class A CNS 13438 Class A KSC 5858 Class A, GB9254 Class A, EN61000-3-2, GB17625.1, EN61000-3-3
Immunity EN55024 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11
Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, markings MIC, UL/cUL, UL/LVD, UL/S-mark, CCC
Dimensions and Weight
Height 44 mm (1.746 in.)
Width 425.5 mm (16.75 in.)
Depth 714.4 mm (28.1 in.)
Weight 16.78 kg (36.9 lb.)
Clearance and Service Access
Front 910 mm (36 in.)
Rear 910 mm (36 in.)

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback