Processor |
Number |
1
|
Architecture |
1.0/1.2/1.4-GHz UltraSPARC T1 Chip Multithreaded (CMT)
1.4 GHz is 8 core
1.2 GHz is 8 core
1.0 GHz are 4 or 8-core
CoolThreads Server
ECO-Responsible Server |
Cache memory |
3 MB unified level 2 cache with ECC |
Main Memory |
Capacities |
DIMM slots per memory controller: 4
DIMM type: DDR2 ECC registered DIMMs
DIMM size: 512-MB, 1-GB, 2-GB, or 4-GB
Maximum capacity: 64GB (when configured with 4-GB DIMMs)
Note: DIMMS must be installed in sets of 8. Two basic memory configurations are supported: 8-DIMM or 16-DIMM. All DIMMs must have identical capacity. An 8 DIMM configuration fully populates Rank 0 slots.
|
Standard Integrated Interfaces |
Network |
Four 10/100/1000 Base-T Ethernet autonegotiating ports
|
Network Management |
One dedicated 10/100Base-T Ethernet port |
Remote Management |
SC Serial Management port and Net Management port |
USB |
Front:Two USB 1.1 ports
Rear:Two USB 1.1 ports |
PCI Interfaces |
Three PCI-Express low-profile, 2.5GHz lanes card slots with up to X8 data lanes.
Two PCI-X low-profile, 64-bit, 133 MHz card slots.
Note: Earlier models of the Sun Fire T2000 (non RoHS) used one PCI-X slot (slot 0) for the SAS disk controller.
|
Internal Storage |
Disks |
Up to four 73GB or 146GB HDD Disks (Hot Pluggable, SFF, SAS, 10K RPM). |
Removable Media |
1 slimline DVD-R/CD-RW drive |
Power Supplies
|
Two hot-swappable, redundant, high efficiency 450W power supplies.
Note: Earlier models of the Sun Fire T2000 (non RoHS) used 550W power supplies.
The Sun SPARC Enterprise T2000, RoHS:YL server has two hot-swappable, redundant, high efficiency 450W power supplies.
These are the electrical limits and ranges for the Sun SPARC Enterprise T2000 server utilizing 450 W power supplies:
|
Operating input voltage range |
100 to 240 VAC, 50-60 Hz |
Maximum operating input current |
4.5 A at 100 to 120 VAC
2.25 A at 200 to 240 VAC |
Maximum operating input power |
400 W |
Maximum heat dissipation |
1,535 BTU/hr |
Nominal Power |
275 W |
Space, Watts and Performance (SWaP) |
Space (RU) |
2 |
Watts |
300 |
Performance (application tier benchmark) |
5300 |
Performance/watt |
17.667 |
SWaP |
8.8 |
Environment |
Temperature |
Operating (Sea Level to 3000 ft(900m)): 5° C to 35° C (41° F to 95° F)
Non-operating: -40° C to 60° C (-40° F to 140° F)
Operating (Above 3000 ft(900m)):Decrease maximum temperature as altitude
increases, 1.6°F/1000 ft (1°C/300m)
Non-operating: -40° C to 60° C (-40° F to 140° F)
|
Humidity |
Operating: 20% to 80% relative humidity noncondensing, 27° C (80.6° F) web bulb, IEC 60068-2-3&56
Non-operating: 98% relative humidity 38° C (100.4 ° F) noncondensing,IEC 60068-2-3&56 |
Altitude |
Operating: up to 3000 m (10,000 ft.), IEC 60068-2-13
Non-operating: up to 12,000 m (40,000 ft.), IEC 60068-2-13 |
Acoustic noise - LPAm (bystander positions) |
Operating: 62 dB
Idling: 62 dB |
Acoustic noise - LwAd (1 B = 10 dB) |
Operating: 7.7 B
Idling: 7.7 B |
Vibration |
Operating: 0.2 Gs, Swept sine 5-500-5Hz, 1 octave/min, all axes, IEC 60068-2-13
Non-operating: 1.0 Gs, Swept sine 5-500-5Hz, 1 octave/min, all axes, IEC 60068-2-13 |
Shock |
Operating: 5.0 Gs peak 11 msec, half-sine pulse, IEC 60068-2-27
Non-operating: 30.0 Gs peak 11 msec, half-sine pulse, IEC 60068-2-27 |
Cooling |
3 hot-swappable and redundant system fans.
1 hot-swappable blower unit.
|
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC 825-1,2, CFR21 part 1040, CNS 14336, GB4943 |
Ergonomics |
EK1-1TB-2000 |
RFI/EMI |
EN55022 Class A, 47
CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NC 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A, EN61000-3-2, GB17625.1, EN61000-3-3 |
Immunity |
EN55024, IEC 61000-2, IEC 61000-3, IEC 61000-4, IEC 61000-5, IEC 61000-6, IEC 61000-8, IEC 61000-11 |
Telecommunications |
EN300-386 |
Regulatory Markings (pending) |
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/DEMKO/GS, UL/S-mark, CCC |
Dimensions and Weight |
Height (2 rack units) |
89 mm (3.5 in.) |
Width |
440 mm (17.3 in.) |
Depth |
617 mm (24.3 in.) |
Weight, approximate (without PCI cards and rack mounts) |
17 kg (37 lb.) |
Clearance and Service Access |
Front |
91 cm (36 in.) |
Rear |
91 cm (36 in.) |
Rack Mounting |
SR900-38 |
Sun Rack 900 - 38 (alloy) |
SR900-36N |
Sun Rack 900 - 36N (alloy) |
Sr1000-38 |
Sun Rack 1000 - 38 (alloy) |
SR1000-42 |
Sun Rack 1000 - 42 (alloy) |
SG-XARY030A |
Sun StorEdge 72-inch expansion cabinet |
|