Processor |
Number |
1
|
Architecture |
1.0-GHz UltraSPARC T1 Chip Multithreaded (CMT)
1.0 GHz are 6 or 8-core
CoolThreads Server
ECO-Responsible Server |
Cache memory |
3 MB unified level 2 cache with ECC
16-KB primary instruction cache per core
8-KB primary data cache per core |
Main Memory |
Capacities |
DIMM slots per memory controller: 4
Total DIMM slots: 8
DIMM type: DDR2 ECC registered DIMMs
DIMM size: 512-MB, 1-GB, 2-GB, or 4-GB
Maximum capacity: 32GB (when configured with 4-GB DIMMs)
Note: DIMMS must be installed 4 at a time (with one pair on each controller).
Two basic memory configurations are supported: 4-DIMMs or 8-DIMMs. All DIMMs must have identical capacity.
|
Standard Integrated Interfaces |
Network |
Four 10/100/1000 Base-T Ethernet auto-negotiating ports
|
Remote Management (ALOM) |
Two SC management ports
One RJ-45 serial management port (SERIAL MGT)
One RJ-45 network management port (NET MGT) |
Serial |
One DB-9 (TTYA) serial port. |
PCI Interfaces |
One PCI-Express (PCI-E) low-profile slot
Note: This slot supports 1x, 4x, and 8x width cards.
|
Internal Storage |
Disks |
One 160 GB SATA disk drive, 3.5" form factor
or
Two 73GB SAS disk drives, 2.5" form factor (firmware upgrade required). or
Two 146 GB SAS disk drive, 2.5" form factor.
|
Power Supplies
|
The Sun SPARC Enterprise T1000 includes one 300W, non-redundant power supply.
|
Operating input voltage range |
100 to 240 VAC, 50-60 Hz |
Maximum operating input current |
2.2 A at 100 to 120 VAC
1.1 A at 200 to 240 VAC |
Maximum operating input power |
220 W |
Typical operating input power |
180 W |
Typical heat dissipation |
614 BTU/hr. |
Maximum heat dissipation |
750 BTU/hr. |
Space, Watts and Performance (SWaP) |
Space (RU) |
1 |
Watts |
180 |
Performance (application tier benchmark) |
53,026 |
Performance/watt |
294.589 |
SWaP |
294.6 |
Environment |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Non-operating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Operating: 10% to 90% relative humidity, noncondensing, 5° C to 35° C (41° F to 95° F)
Non-operating: 95% relative humidity, noncondensing, -40° C to 70° C (-40° F to 158° F) |
Altitude |
Operating: up to 3048 m (10,000 ft.), IEC 60068-2-13
Non-operating: up to 12,000 m (40,000 ft.), IEC 60068-2-13 |
Acoustic noise - LPAm (bystander positions) |
Operating: 66 dB
Idling: 66 dB |
Acoustic noise - LwAd (1B = 10dB) |
Operating: 7.7 B
Idling: 7.7 B |
Cooling |
Power supply cooling fan.
1 system fan assembly (contains four 40-mm fans).
|
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC 825-1,2, CFR21 part 1040, CNS 14336, GB4943 |
RFI/EMI |
EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A,
GB9254 Class A, EN61000-3-3, GB17625.1, EN61000-3-3 |
Immunity |
EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 |
Telecommunications |
EN300-386 |
Regulatory Markings |
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark, CCC |
Dimensions and Weight |
Height (1 rack unit) |
43 mm (1.75 in.) |
Width |
425 mm (16.7 in.) |
Depth |
467 mm (18.4 in.) |
Weight, approximate (without PCI card and rackmounts) |
9.1 kg (20 lb.) |
Weight, approximate (with slide rails) |
10.9 kg (24 lb.) |
Clearance for Service Access |
Front |
91 cm (36 in.) |
Rear |
91 cm (36 in.) |
Rack Mounting |
SR900-38 |
Sun Rack 900 - 38 (alloy) |
SR900-36N |
Sun Rack 900 - 36N (alloy) |
SR1000-38 |
Sun Rack 1000 - 38 (alloy) |
SR1000-42 |
Sun Rack 1000 - 42 (alloy) |
SG-XARY030A |
Sun StorEdge 72-inch expansion cabinet |
|
Sun Fire cabinet |