Processor |
Number |
Up to 16 CPUs
SPARC64 VI: Up to 32 Cores
SPARC64 VII: Up to 64 Cores
SPARC64 VII+: Up to 64 Cores |
Architecture |
SPARC64 VI: 2.28GHz and 2.4GHz SPARC V9, ECC protected
SPARC64 VII: 2.52GHz SPARC V9, ECC protected
SPARC64 VII+: 3.00GHz SPARC V9, ECC protected |
Cache memory |
SPARC64 VI: 6MB Shared Level 2 on Chip Cache per Processor, 128KB
I-Cache and 128KB D-Cache Level 1 per Core
SPARC64 VII: 6MB Shared Level 2 on Chip Cache per Processor, 64KB I-Cache and 64KB D-Cache Level 1 per Core
SPARC64 VII+: 11MB Shared Level 2 on Chip Cache per Processor, 64KB I-Cache and 64KB D-Cache Level 1 per Core
|
System
Boards |
CPU/Memory Units (CMU) |
Up to 4 |
I/O |
Up to 4 External I/O Expansion Units |
eXtended System Control Facility Unit (XSCFU) |
2 (redundant) |
Maximum Number of Domains |
16 |
Main
Memory |
Maximum 1TB using 8GB DIMMs, 128 DIMM slots |
Standard
Interfaces |
Ethernet |
2 × 10/100 XSCF-LAN Ports per XSCFU |
PCI Express |
32 Slots, expandable up to 112 Slots, via optional external
I/O Expansion Units |
Serial |
1 RJ-45 per XSCFU |
USB |
1 port per XSCFU that a field engineer can use to download
hardware information |
Internal
Mass Storage |
Disks |
Up to 16 disks, 4 per I/O Unit, 73GB, 146GB, or 300GB SAS Disk Drives supported |
DVD-ROM |
1 |
Tape |
1 Optional DAT72 Tape Drive |
Power
Supplies |
9 Power Supply Units (PSU) M8000 Base Cabinet |
Environment
|
AC power |
200 to 240 VAC |
Power Consumption |
10.5 kW (4 CMUs and 4 IOUs installed) |
Apparent Power |
11.0 kVA (4 CMUs and 4 IOUs installed) |
Power Factor |
0.9 or higher |
Rush Current |
100A0-p or less (current for each cable) |
Leak Current |
30mA or less |
Heat output (cooling requirement) |
See Sun SPARC Enterprise M8000/M9000 Servers Site Planning Guide (819-4203) |
There are a number of different power options available for
the M8000. For more specific details on the specifications related to them,
please see the Sun SPARC Enterprise M8000/M9000 Servers Site Planning Guide (819-4203). |
Power cords |
See Sun SPARC Enterprise M8000/M9000 Servers Site Planning Guide (819-4203) |
Temperature |
Operating:
Altitude 0 to less than 1500 Meters (0 - 4920 ft): 5° C to 32°
C ( 41° F to 89.6° F)
Altitude 1500 to less than 2000 Meters (4921 - 6561 ft): 5°
C to 30° C ( 41° F to 86° F)
Altitude 2000 to less than 2500 Meters (6562 - 8201 ft): 5°
C to 28° C ( 41° F to 82.4° F)
Altitude 2500 to less than 3000 Meters (8202 - 9843 ft): 5°
C to 26° C ( 41° F to 78.8° F)
Nonoperating: 0° C to 50° C ( 32° F to 122° F) |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 8% to 80% relative humidity, noncondensing |
Altitude |
Up to 3000M (9843 ft) |
Regulations
Meets or exceeds the following requirements: |
Safety |
CSA/UL-60950, EN60950, IEC950 CB Scheme with all national
deviations |
RFI/EMI |
EN55022/CISPR22 Class A, FCC CFR47 Part 15 Class A, EN61000-3-2,
EN61000-3-3 |
Immunity |
EN55024, EN61000-4-2, -4-3. -4-5. -4-6, -4-8, and -4/11 |
Regulatory Markings |
CE, FCC, ICES, C-tick, VCCI, GOST-R, BSMI, MIC, CSA/UL |
RoHS Compliance Level |
RoHS:YL |
Other Marks |
WEEE and China RoHS |
Dimensions
and Weights |
Height |
M8000: 180 cm (70.9 in.)
Power Expansion Cabinet: 180 cm (70.9 in.) |
Width |
M8000: 75 cm (29.5 in.)
Power Expansion Cabinet: 31.7 cm (12.5 in.) |
Depth |
M8000: 126 cm (49.6 in.)
Power Expansion Cabinet: 124.4 cm (49 in.) |
Weight |
M8000: 700 kg (1540 lb.)
Power Expansion Cabinet: 350 kg (770 lb.) |
Clearance
and Service Access |
Front |
80cm (31.5 in) |
Rear |
80cm (31.5 in) |
For more information, see the Sun SPARC Enterprise M8000/M9000 Servers Site Planning Guide (819-4203) |