Processor |
Number |
Up to 8 CPUS 2 per System Board, up to 4 System Boards
SPARC64 VI: Up to 16 Cores
SPARC64 VII: Up to 32 Cores
SPARC64 VII+: Up to 32 Cores |
Architecture |
SPARC64 VI: 2.15GHz Dual Core processors, SPARC V9, ECC Protected
SPARC64 VII: 2.4GHz Quad Core processors, SPARC V9, ECC Protected
SPARC64 VII: 2.53GHz Quad Core processors, SPARC V9, ECC Protected
SPARC64 VII+: 2.66GHz Quad Core processors, SPARC V9, ECC Protected |
Cache memory |
SPARC64 VI: 5MB Shared Level 2 on Chip Cache per Processor, 128KB
I-Cache and 128KB D-Cache Level 1 per Core
SPARC64 VII: 5MB Shared Level 2 on Chip Cache per Processor, 64KB I-Cache and 64KB D-Cache Level 1 per Core
SPARC64 VII+:11MB Shared Level 2 on Chip Cache per Processor, 64KB I-Cache and 64KB D-Cache Level 1 per Core
|
Main
Memory |
Capacities |
16GB (using 1GB DDR2 DIMMS) to 512GB (using 8GB
DDR2 DIMMs), 8 slots per board, 8 memory boards per system.
|
Standard
Interfaces |
Ethernet |
2 × Gigabit Ethernet ports, also 2 × 10/100
ethernet ports for accessing CLI and browser based interface on Extended
System Control Facility (XSCF) |
PCI-X / PCI-Express |
1 × PCI-X Slot, 4 × PCI-Express Slots
per I/O tray |
Serial |
1 RJ-45 - on XSCF to access CLI |
USB |
One port on XSCF that field engineer can use to
download hardware information |
Internal
Mass Storage |
Disks |
Up to 4 internal 73GB, 146GB or 300GB SAS Disk Drives |
DVD-ROM |
1 CD-RW / DVD-RW |
Tape |
DAT72 Tape Drive (optional) |
Power
Supplies |
Type |
4× 100-240 VAC, 2000W, 1-phase
(50-60Hz), 12 amp per power cord, 2 - 4 power cords (2 + 2 redundant, second
and fourth power supplies are redundant at 200 VAC) |
Output |
4590 Watts (4 power cords) |
Environment |
AC Power |
100-240VAC |
Power Draw |
4590 Watts (4 power cords) |
Volt Ampere |
3815 VA |
Input power |
100 - 127 VAC
200 - 240 VAC |
Maximum Current |
48A at 100 127 VAC, 12A / cord
24A at 200 240 VAC, 12A / cord |
Heat output |
12754 BTU/hr (13457 kJ/hr) - 4 CPU modules, 256GB
memory |
Temperature |
Operating: 5° C to 35° C (41°
F to 95° F) *
Nonoperating: -20° C to 60° C (-4°
F to 140° F) *
Optimal: 21°
C to 23° C (70° F to 74° F) x2 |
Humidity |
Operating: 20% to 80% relative humidity,
noncondensing
Nonoperating: Up to 93% RElative humidity,
noncondensing
Optimal: 45%
to 50% relative humidity, noncondensing |
Altitude |
Operating: Up to 3000m (10000 ft)
Nonoperating: 12000m (39,370 ft) |
* - derated 2° C for every 1km
up to 3km |
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL, WEEE and Chinese RoHS |
Safety |
CSA/UL-60950, EN60950, IEC950 CB Scheme with all national
deviations |
Ergonomics |
GS |
RFI/EMI |
EN55022/CISPR22 Class-A, FCC CFR47 Part 15 Class A, EN61000-3-2,
EN61000-3-3 |
Immunity |
EN55024, EN61000-4-2, -4-3, -4-5, -4-6, -4-8, -4-11 |
Regulatory Markings |
CE, FCC, ICES, C-tick, VCCI, GOST-R, BSMI, MIC, CSA/UL |
Dimensions
and Weights |
Height |
44.02cm (17.33 in) |
Width |
44.4cm (17.48 in) |
Depth |
81cm (31.9 in) |
Weight |
125kg (275 lbs) |
Power Cord |
2 - 4, 4m (13 ft) *
Americas, Japan, & Taiwan: NEMA L5-15 125V
15A, NEMA L6-20 250V 20A
All other locations except Japan & Taiwan: IEC 60309 16A 250V,
3PIN with IEC60309 C20 |
* - 4 power cords required for redundancy
|
Clearance
and Service Access |
Front |
91.4cm (36 in) |
Rear |
91.4cm (36 in) |
Right |
n/a |
Left |
n/a |
Top |
91.4cm (36 in) |
Airflow |
Front to back - 16.9 cubic meters per minute (600 cfm) in normal
operating conditions |
Rack
Mounting |
Sun Rack 1000-38, Sun Rack 1000-42,
Sun Rack 900 |