| Processor |
| Number |
One CPU |
| Architecture |
SPARC64 VII: 2.52GHz or 2.75GHz Dual or Quad Core processor,
SPARC V9, ECC Protected
SPARC64 VII+: 2.86GHz Dual or Quad Core processor, SPARC V9, ECC
Protected |
| Cache memory |
SPARC64 VII: 5MB Shared Level 2 on Chip Cache, 64KB
I-Cache and 64KB D-Cache Level
SPARC64 VII+: 5.5MB Shared Level 2 on Chip Cache, 64KB I-Cache and
64KB D-Cache Level |
| Main
Memory |
| Capacities |
8GB (using 1GB DDR2 DIMMS) to 64GB (using 8GB DDR2
DIMMs), 8 slots per system. DIMM sizes: 1GB, 2GB, 4GB and 8GB.
|
| Standard
Interfaces |
| Ethernet |
4 × integrated Gigabit Ethernet ports also
2 × 10/100 ethernet ports for accessing CLI and browser based interface
on Extended System Control Facility (XSCF) |
| PCI-X / PCI-Express |
4 × X8 PCI-E Slots |
| Serial |
One RJ45 |
| USB |
One port on XSCF that field engineer can use to
download hardware information |
| SAS |
One external SAS port (two-lane) |
| Internal
Mass Storage |
| Disks |
Up to 4 internal 146GB SAS Disk Drives |
| DVD-ROM |
1 DVD-RW |
| Tape |
None |
| Power
Supplies |
| Type |
1 or 2 × 100-240 VAC, 565W,
1-phase (50-60Hz), 12 amp per power cord |
| Output |
600 Watts (2 power cords) |
| Environment |
| AC Power |
100-240VAC |
| DC Power |
~48V/~60V |
| Input power |
100 127 VAC
200 240 VAC |
| Power Draw |
470 Watts (2 power cords) |
| Maximum Current |
24.0A at 100 127 VAC, 12A / cord
12.0A at 200 240 VAC, 12A / cord |
| Heat output |
2150 BTU/hr |
| Temperature |
Operating: 5° C to 35° C (41°
F to 95° F) *
Nonoperating: -20° C to 60° C (-4°
F to 140° F) *
Optimal: 21°
C to 23° C (70° F to 74° F) |
| Humidity |
Operating: 20% to 80% relative humidity,
noncondensing
Nonoperating: 8% to 80% relative humidity,
noncondensing
Optimal: 45%
to 50% relative humidity, noncondensing |
| Altitude |
Operating: Up to 3048m (10000 ft)
Nonoperating: 12000m (40000 ft) |
| * - derated 2° C for every 1km
up to 3km |
Regulations
Meets or exceeds the following requirements: |
| RoHS Compliance Level |
RoHS:YL, WEEE and Chinese RoHS |
| Safety |
CSA60950-1-03, UL60950-1, IEC60950-1, 1(2001), GB4943-2001
Scheme with all national deviations |
| Ergonomics |
N/A |
| RFI/EMI |
FCC part-15, EN55022/CISPR22, VCCI, AS/NZS CISPR 22, EN 300
386, EN61000-3-2, EN61000-3-3, JISC61000-3-2, KN22, GB9254, GB17625 |
| Immunity |
EN55024, EN 300 386, KN24 |
| Regulatory Markings |
CE, FCC, VCCI, CSA C/US |
| Dimensions
and Weights |
| Height |
8.7 cm (3.43 in) |
| Width |
44 cm (17.33 in) |
| Depth |
65.7 cm (25.87 in) |
| Weight |
22kg (48.50 lbs) |
| Power Cord |
1 - 2, 4m (13 ft) *
Americas, Japan, & Taiwan: NEMA L5-15 125V 15A, NEMA L6-20 250V 20A
All other locations except Japan & Taiwan: IEC 60309 16A 250V, 3PIN
with IEC60309 C20 |
| * - 2 power cords required for redundancy |
| Clearance
and Service Access |
| Front |
91.4cm (36 in) |
| Rear |
91.4cm (36 in) |
| Right |
none - front to back cooling |
| Left |
none - front to back cooling |
| Top |
91.4cm (36 in) |
| Airflow |
Front to back - 8.5 cubic meters per minute (300 cfm) in normal
operating conditions |
| Rack
Mounting |
| Sun Rack 1000-38, Sun Rack 1000-42,
Sun Rack 900 |