Processor |
Number |
1 to 2 Quad-Core or 6-Core |
Architecture |
Type: Intel Xeon Quad-Core or 6-Core Processors |
CPUs |
Intel 2.40GHz Quad-Core Xeon L5620 (12MB L2, 80W)
Intel 2.26GHz 6-Core Xeon L5640 (12MB L2, 60W)
Intel 2.93GHz 6-Core Xeon E5670 (12MB L2, 95W)
|
Main Memory |
Capacities |
Total DIMM slots: 18
DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
DIMM size: 4-GB 1333MHz or 8-GB 1066MHz
Maximum capacity: 144GB (when configured with 8-GB DIMMs)
|
Standard
Integrated Interfaces |
Network |
Four 10/100/1000 Base-T Ethernet Ports
|
Network Management |
One dedicated 10/100Base-T Ethernet port |
Serial Management |
One dedicated TIA/EIA-232-F asynchronous RJ45 port |
SAS |
Four channel SAS interface, internal access only |
USB |
Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port (for a USB thumb drive) |
PCI Expansion Slots |
Three low profile PCI Express 2.0 slots
(1 x16 electrical/mechanical, 2 x8 electrical/mechanical) |
Crypto Accelerator |
Device |
Oracle SCA 6000 Cryptographic Accelerator Card, 8-Lane PCI Express |
Number |
One |
Internal Mass Storage |
Disks |
SAS: Up to eight 2.5" SATA Disks
(500GB - 7200 RPM - SATA Disk)
|
DVD-ROM |
One SATA DVD+/-RW drive |
Power Supplies |
Dual redundant, hot swappable power supplies
(Power supply rating output = 760W)
(UL Maximum AC input = 760W x 1.33 efficiency = 1010W)
(9.0 Amps RMS at 100 VAC)
|
Environment |
AC power |
100-120 / 200-240 VAC (50-60 Hz) |
Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to
158° F)
|
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb |
Altitude |
Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient
temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.) |
Regulations
Meets or exceeds the following
requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
UL 60950-1 2nd Ed, EN60950-1:2006 2nd Ed, CB Scheme with all country
differences |
RFI/EMI |
FCC CFR 47 Part 15 Subpart B Class A, EN55022:2006+A1:2007 Class A, EN 61000-3-2,
EN61000-3-3, EN 300-386 |
Immunity |
EN55024, EN300-386 |
Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
|
Dimensions and Weight |
Height |
43.43 mm (1.71 in.) |
Width |
425.5 mm (16.75 in.) |
Depth |
685.8 mm (27.0 in.) |
Weight |
16.36 kg (36 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
|
Rack Mounting |
Sun Fire X4170 M2 Server Racks |
Racks are as follows:
- Sun Rack 938
- Sun Rack 1038
- Sun Rack 1042
- Sun Rack II 1042
- Sun Rack II 1242
|