Note: Modular System (chassis) specifications are documented on the chassis specification page.
Reference the Servers/Telco Systems section of the Handbook's Systems List to find documentation on Modular Systems.
|
Processor |
Number |
Up to two.
|
Architecture |
Type:Six-core, Intel[tm] Xeon 5600 series processors with QuickPath Interconnect (QPI), Turbo Boost and Hyper-Threading (HT) technology.
- Model/Speed/Watts: L5638, 2.0 GHz, 60W
|
Cache Memory |
32KB instruction and 32KB data L1 cache per core
256KB unified (data and instruction) L2 cache per core
12MB shared inclusive L3 cache per processor
|
Main Memory |
Memory Type |
DDR3-1066/PC3-8500 and DDR3-1333/PC3-10600 DIMMs.
|
Capacities |
- Total DIMM slots: 18.
- DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
- DIMM sizes: 8 GB 1066MHz. 4GB 1333MHz.
- Maximum capacity: 144 GB (when configured with 8-GB DIMMs).
|
Optional Storage |
Disk |
- Up to four optional, hot swappable, hot pluggable, Small Form Factor (SFF) 2.5" drive bays per Server Module.
Four SAS-2 interfaces to the midplane, two to each Network Express Module slot. Note: RAID Expansion Module is required for SAS support.
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS
|
146.8 GB
|
10,000 RPM
|
2.5"
|
SAS
|
300 GB
|
10,000 RPM
|
2.5"
|
|
Management Environment
|
Server Module Service Processor (SP) |
- The SP is not a separate card. It is embedded on the motherboard.
- The SP is installed with Integrated Lights-Out Manager (ILOM 3.0).
- The SP provides one 10/100 Management Ethernet Port to Midplane and the Chassis Monitoring Module (CMM).
- ILOM on the SP card can be accessed via the Dongle cable assembly.
- The three-cable (X4622A) dongle cable option
can be used to connect to ILOM using the Universal Connector Port (UCP) on the front of the Sun Netra X6270 M2.
- Use the RJ-45 serial connector on the 3-cable dongle to connect to ILOM via the UCP.
- The SP card and LOM provide the following:
- Remote management with full Keyboard, Mouse, Video, Storage (KVMS) redirection.
- Remove media capability (floppy, DVD, CD etc.).
- DMTF style CLI.
- Support for SSH 2.0, HTTPS, RADIUS, LDAP, and Microsoft Active Directory.
- Browser-based GUI for control of the system through a graphical interface.
- IPMI 2.0 compliance for management and control.
- SNMP V1, V2c, V3 for system monitoring.
- Monitor and report system and component status on all FRUs.
|
Standard Integrated Interfaces |
Front Panel I/O
|
The Dongle Cable assembly connects to the UCP and provides the following:
- Connection to ILOM SP.
- Dual USB 2.0 ports.
- VGA video connection to an on-board AST2100 graphics chip.
|
Network Management |
One dedicated 10/100Base-T Ethernet port.
|
Ethernet |
Two 10/100/1000Base-T Gigabit Ethernet ports using an Intel 82576EB Gigabit
Ethernet Controller, one interface to each Network Express Module (NEM) slot.
|
PCI Interfaces with the Sun Netra Modular System (chassis) |
- I/O is offered in two form factors:
- PCI Express ExpressModules (EM)
and
- PCI Express Network Express Module.
- Each Sun Netra X6270 M2 has four, PCI Express Gen 2 links allocated to:
- Two EMs (X8)
and
- Two NEMs (X8).
- Each NEM has one link assigned to each server module. All server modules
share the NEM. For example, Netra 0 has access to NEM 0/slot 0,
and NEM 1/slot 0. Netra 1 to NEM 0/slot 1 and NEM 1/slot 1, etc.
- EM slots are not shared between server modules. Each EM slot is
specific to one server module.
|
Graphics |
- 2D graphics controller with 8MB video memory embedded inside SP.
- Supports resolutions up to 1600x1200x16 bits @60 Hz (1024x768 when viewed
remotely via ILOM RKVMS).
|
Regulations
|
RoHS Compliance Level |
RoHS:Y |
Dimensions
and Weights |
Height |
44mm (1.7 in). |
Width |
327mm (12.87 in). |
Depth |
512mm (20.16 in). |
Weight |
7.9 kg (17.4 lbs) fully populated. |