Processor |
Number |
Up to 2 Dual-core |
Architecture |
Type: AMD Opteron Processor model 2214 HE
embedded-class (2214-2.2GHz)
|
Cache memory |
1 MB Level 2 Cache per core
|
Main Memory |
Capacities |
DIMM slots per CPU socket: 4
DIMM slots per System Board: 8
DIMM type: DDR2-667 registered ECC DIMMs
(128-bit plus ECC databus)
DIMM size: 1-GB, 2-GB or 4-GB
Maximum capacity: 32 GB (max 16GB for single processor
systems)
|
Standard
Integrated Interfaces |
Network |
Four 10/100/1000Base-T Ethernet ports |
Network Management |
One 10/100Base-T Ethernet port |
Serial Management |
One TIA/EIA-232-F asynchronous RJ45 port |
SAS |
Four-Channel SAS Interface, internal access only |
USB (2.0)
|
Rear: 2
(500 mA=max output supply current of each USB port)
|
Video
|
One VGA Video port (HD-15)
|
Alarms
|
Four DB-15 dry
contact
(critical, major, minor and user)
|
Expansion Bus |
Three full-height internal 64-bit 133MHz PCI-X slots
- 2-full length
- 1-half-length
One internal x8 PCI-Express MD2 low profile slot
|
Internal Mass Storage |
Option 1
|
DVD, up to two 146GB 2.5in 10K
RPM SAS disks, maximum capacity 292 GB |
Option 2
|
No DVD, Up to four 146GB 2.5in
10K RPM
SAS disks, maximum capacity 584 GB
|
DVD-ROM |
One Slimline DVD/RW
|
NOTE: A two-disk
Netra X4200 M2 chassis with DVD-ROM (or w/out DVD-ROM)
cannot be field converted to a four-disk Netra X4200 M2, or vice versa. |
Power Supplies |
Two 500W (1+1)
hot-swappable AC or DC
Note: To ensure redundant
operation of the power supplies, the two power inputs should be
connected to separate power sources.
|
Operating input voltage range
|
AC=100-240 VAC, 50-60 Hz
DC=-48VDC or -60VDC (nominal) / -40VDC - -75VDC (range)
|
Max operating input current
|
AC=6.4A at 100-120 VAC / 3.2A at
200-240 VAC
DC=12.7A at -48VDC / 10.2A at -60VDC
|
Max heat dissipation
|
AC=2150 BTU/hr
DC=2085 BTU/hr
|
Nominal Power
|
AC & DC=Estimated 475 W
|
Maximum Power
|
550 W
|
Environment |
Temperature |
Operating: 5° C to 40° C (41° F to
104° F)/Short term: 5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to
158° F)
Storage: 40° C to
-70° C (-40° F to 158° F)
|
Humidity |
Operating: 5% to 85% relative humidity noncondensing,
max wet bulb. Short term: 5% to 90% relative humidity
noncondensing, but not to exceed 0.024kg water/kg dry air (0.053 lbs.
water 2.205 lb. dry air)
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb
|
Altitude |
Operating: up to 3,000m (9,850 ft.) @40° C
(104° F)
Nonoperating: up to 12,000m (40,000 ft.) |
Acoustic noise |
Operating/Idling Acoustic Noise 7.0B (LwAd, 1B=10dB) |
Regulations
Meets or exceeds the following
requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all
country deviations, IEC825-1, 2, and CFR21 part 1040, CNS14336, GB4943 |
RFI/EMC |
EN55022/CISPR22 Class A, FCC CFR47 Part 15 Class A,
EN61000-3-2, EN61000-3-3
ICES-003 Class A, VCCI Class A, AS/NZ 3548 Class A, CNS13438 Class A,
KSC 5858 Class A, GB9254 Class A, GB17625.1
|
Immunity |
EN55024/CISPR24
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC
61000-4-6, IEC 61000-4-8, IEC 61000-4-11 |
Telecommunications
|
EN 300 386, Telecordia SR 3580
NEBS Level 3
|
Regulatory Markings (Pending)
|
CE, FCC, ICES-003, C-tick, VCCI,
GOST-R, BSMI, MIC, UL/cUL, UL/DEMKO/GS, UL/S-mark, CCC
|
ETSI
|
EN 300 019-2-1,2,3, Class 1.2,
2.3, 3.1E
- Except -5C cold start
- Except condensing humidity
- Except rain
|
Seismic
|
GR-63-CORE requirements for
earthquake zone 4
|
Dimensions and Weight |
Height |
89 mm (3.5 in.) 2 RU
|
Width |
442 mm (17.4 in.) including bezel / 424 mm (16.7 in.) not
including bezel
|
Depth |
508 mm (20 in.) max depth / 483 mm (19 in.) to the connector
plane
|
Weight |
Approximate (without PCI cards or rack mounts)
16 kg (35 lb.) 2 disk version
17 kg (37.2 lb.) 4 disk version
|
Rack Mounting |
Rack Units
|
2
|
Fits into standard
19-inch wide rack. Rack kit included: 19-inch 4-post |
|
Additional Rack Kits Available |
- 19-inch 2-post
- 23-inch 2-post
- 600mm x 600mm and
- 19-inch 4-post slide adjustable1
|
1 The slide kit includes hardware that
enables mounting to any of the following types of rack rails:
- 6 mm threaded holes
- #10-32 threaded holes
- #10 threaded holes
These must be compliant racks which have mounting
depths of 27-30 inches. |