Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra[tm] 1280, RoHS:YL Server: Hardware Specifications

Processor
Number 4, 8, or 12
Architecture UltraSPARC[tm] III Cu 1200MHz
Cache per processor Primary (L1): Parity protected 32 KB instruction and 64 KB data on chip (single-bit errors are corrected)
Secondary (L2): 8 MB external cache
System Interconnect 9.6 GB/s Sun Fireplane interconnect.
System bus with redundant data, address and response crossbar interconnect
System Boards
Number of boards Maximum of 3 CPU/Memory boards
CPU/Memory board Four processors each and up to 32 GB memory per board; maximum 12 processors per server
Main Memory
8 GB to 96 GB (Using 1 GB DIMMS)
Standard Interfaces
Alarm One alarm port (DB15)
Ethernet
  • One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair port (RJ-45)
    (Used for LOM/System Controller)
  • Two 10/100/1000BASE-T Ethernet (copper) ports
PCI

Six open 7 in., 64 bit PCI slots:

  • One 66MHz
  • Five 33MHz
Serial
  • One RS-232/RS-423 asynchronous/synchronous serial port (RJ45), Serial A
  • Serial B is reserved.
SCSI

One Ultra3 SCSI 68-pin SCSI port

  • Single-ended (40MB/sec) or
  • LVD (160MB/sec)
Internal Mass Storage
Disks Two 73GB SCSI internal disks, 1.0 in., 10,000 RPM
DVD-ROM DVD-ROM internal drive
Power Supplies
Four power supplies providing 2N hot-pluggable redundancy; only two are required for the system to run.
Environment
DC input
-48VDC or -60VDC
Input power 3300W maximum
Heat output

Base Configuration: 4,780 BTU/hr
Maximum Configuration: 11,300 BTU/hr

Temperature Optimal: 22° C (72° F)
Range: 5° C to 40° C (41° F to 104° F)
Humidity Optimal: 45% non-condensing
Range: 10% to 90% non-condensing humidity
Altitude Up to 3,048 meters (10,000 ft)
Acoustic noise 73 dB(A)
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety North America: UL 60950 3rd edition, CSA C22.2 No 60950-00 3rd edition (Certified: UL and UL for Canada)
European Community: EN 60950:2000, (Certified: UL for Germany/GS-Mark and GOST R for Russia)
Worldwide except North America: IEC 60950:1999 and CB Bulletin (Certified: DEMKO + UL for Argentina/IRAM S-Mark)
RFI/EMI Class A: Australia/New Zealand AS/NZ 3548, Industry Canada ICES-003, European Community EN55022/CISPR22, Japan VCCI, Taiwan CNS 13438, and US FCC 47CFR15.B.
Immunity EN55024, i.e. EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, and EN61000-4-11
Dimensions and Weights
Height Chassis Only: 20.75 in (527 mm) / 12U
With Cradle: 21 in (533.4 mm)
Width 

Chassis Only: 16.75 in (425.6 mm)
With Baseline Skirt: 17.38 in (441.4 mm)
With Slides: 17.5 in (445 mm)

Depth 

Chassis Only: 22 in (558 mm)
With Slides: 22.36 in (568 mm)

Weight  Chassis Only: 235.89 lbs (107 kg)
With Cradle: 286.60 lbs (130 kg)
Clearance and Service Access
Front 35 in (88.9 cm)
Rear 35 in (88.9 cm)
Refer to the Sun Fire V1280 / Netra 1280 Site Preparation and Installation Guide for clearance and service access details.
Racking
All Sun racks and most third party; 24 in. (600mm) and deeper racks; 2 per 4 post rack, 1 per 2 post rack
  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.