Processor |
Number |
One |
Architecture |
Next-Generation AMD Opteron 1000 Series (dual core only) 1218 (2.6 GHz),
1214 (2.2 GHz), 1210 (1.8GHz)
x16 HyperTransport 8 GB/s (Processor to South Bridge)
|
Cache memory |
1 MB Level 2 per core |
Main
Memory |
Capacities |
DIMM slots: 4 DIMM slots
DIMM type: Unregistered DDR2-667 ECC DIMMs
DIMM size: 512MB, 1GB, 2GB
Maximum capacity: 8GB |
Standard
Integrated Interfaces |
Network |
4 x Integrated 10/100/1000 Base-T Gigabit Ethernet
Broadcom: ports 0,1
NVIDIA: ports 2, 3 |
Network Management |
1 Dual Port 10/100/1000 Base-T Gigabit Ethernet (one of four network ports) |
Serial Management |
1 Serial DB-9 Port |
USB |
Front: 2 USB 2.0 Ports
Rear: 4 USB 2.0 Ports |
PCI Express |
Riser card assembly with two internal 8-lane, low-profile, half length
PCI Express slots
25 W max per card |
Graphics controller |
ASPEED AST2000 |
Crypto Accelerator |
Device |
Sun Crypto Accelerator 6000, x8 PCI Express |
Number |
One |
Internal
Mass Storage |
Disks |
Up to 2 - 250 GB, 500 GB or 1 TB SATA 3.5" disk drives |
DVD-ROM |
DVD-ROM (optional) |
Power
Supplies |
Single 345 Watt Power Supply |
Environment |
AC power |
100-240 VAC (47-63Hz) Auto-sensed |
Maximum Input Current |
6.5A @ 100-240V |
Temperature |
Single, non-rack system:
Operating: 2° C to 38° C (36° F to 100° F)
Nonoperating: -40° C to 68° C (-40° F to 154°
F) |
Humidity |
Single, non-rack system:
Operating: 7% to 93% relative humidity noncondensing, 27° C
(° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38°
C (° F) max wet bulb |
Altitude |
Operating: Up to 3000 m (9843 ft.), maximum operating temperature
is derated by 1� C for every 300 m (985 ft) in altitude. |
Vibration |
Operating: 0.12 G x-y, 0.17 G z; 5 500 Hz sine
Nonoperating: 0.3 G x-y, 0.6 G z; 5 500 Hz sine |
Shock |
Operating: 4.5 G to 3.5 G; 11 msec. half-sine |
Acoustic Noise Emissions |
Declared noise emissions in accordance with ISO 9296, A-weighted, sound
power: LwAd Idle, at or below 25� C: 6.9 B max, at ambient 7.3 B |
Regulations
Meets or exceeds the following requirements: |
Safety |
IEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences |
RFI/EMI |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.31, ICES-003 |
Immunity |
EN55024 ,EN300-386:v1.3.2 |
Certifications |
Safety: CE Mark, GOST, GS Mark, cULus Mark, CB scheme, CCC, S Mark
EMC: CE Mark, Emissions and Immunity Class A Emissions Levels: FCC,
C-Tick, MIC, CCC, GOST, BSMI, ESTI, DOC, S Mark
Other: Labeled per WEEE (Waste Electrical and Electronic Equipment)
Directive |
RoHS Compliance Level |
RoHS:YL |
Dimensions
and Weight |
Height |
43 mm (1.69 in.) |
Width |
425.5 mm (16.75 in.) |
Depth |
633.7 mm (25 in.) |
Weight |
10.66 kg (23.5 lb.) |
Rack
Mounting |
Optional Slide Rail Kit (X8029A)1 |
Is a 4-point mounted slide rail kit. |
1 The slide kit includes hardware that enables
mounting to any of the following types of rack rails:
- 6 mm (M6x1) threaded holes
- #10-32 threaded holes
- #10 clearance holes
- square unthreaded holes per ANSI/EIA 310-D-1992 or IEC 60927 standards
|
Sun Fire X2100 Server Racks (using the X8029A kit) |
Racks are as follows:
- Sun Rack 900
- Sun Rack 1038
- Sun Rack 1042
- Third Party ANSI/EIA 310-D-1992 or IEC 60927 compliant racks
|