Sun Fire[tm] E6900, RoHS:YL Server: Hardware Specifications
Processor |
Number |
4 to 24 |
Architecture |
UltraSPARC[tm] III Cu: 1200MHz
UltraSPARC IV: 1050MHz, 1200MHz, or 1350MHz, superscalar SPARC V9, ECC protected
UltraSPARC IV+: 1.5GHz or 1.8GHz superscalar SPARC V9, ECC protected |
Cache per processor |
UltraSPARC IV:
Primary (L1): 64 KB 4-way data, 32 KB 4-way instruction, 2 KB Write, 2 KB
Prefetch
Secondary (L2): 16 MB external (exclusive access to 8 MB per pipeline), On-chip
controller and address tags
UltraSPARC IV+:
Primary (L2): 2 MB on-chip
Secondary (L3): 32 MB off-chip
|
System Interconnect |
9.6-GB/sec. Sun Fireplane interconnect. System bus with redundant data,
address, and response crossbar interconnect. |
System
Boards |
Number of boards |
Up to 6 |
CPU/Memory board |
4 CPUs with up to 64GB per board; maximum 24 processors per system. |
PCI I/O Assembly
PCI-X I/O Assembly |
Up to 32 × PCI slots (8 × 66 MHz and 24 × 33 MHz)
Up to 32 × 64-bit PCI-X slots (24 × 100 MHz and 8 × 33MHz) |
Main
Memory |
64 GB memory (max) per 4 CPUs on a CPU/Memory board, Up to
384 GB per domain
Maximum system memory capacity of 384 GB (6 × 64GB) |
Standard
Interfaces |
System Controller |
Responsible for the overall control of the system. Each System Controller
includes one RS-232/423 (DB25) serial interface and one 10/100BASE-T ethernet/fast
ethernet (RJ45) interface. Two per system. |
Internal
Mass Storage |
Sun
StorEdge[tm] D240 Media Tray
Sun StorEdge S1 Array |
Power
Supplies |
6 Fault-tolerant, redundant, hot swappable, and hot pluggable
power supplies |
Environment |
AC power |
200-240 VAC, 47-63 Hz, 32 A(per power cord) |
Input power |
9,120 W @ 220V |
Heat output |
31,113 BTU/hr |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F) -
derate 2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140°
F) |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Altitude |
Operating: 0 to 3,000 meters (0 to 10,000 feet)
Nonoperating: 0 to 12,000 meters (0 to 40,000 feet) |
Acoustic noise |
69 dB(A) |
Vibration |
Operating: 0.15 G's, 5 to 500Hz, swept-sine
Nonoperating: 1.5mm single amplitude/0.6 G's, 5 to 500Hz, swept-sine,
vertical 0.75mm single amplitude/0.3 G's, 5 to 500Hz, swept-sine, horizontal |
Shock |
3 G's, 11 ms, half-sine |
Number of cords |
4 |
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
UL 60950, third-edition USA CAN/CSA-C22.2 No. 60950-00, Canada EN 60950,
third-edition, Europe S Mark, Argentina Gost-R, Russia CB Scheme with all
national deviations |
Emissions |
EN55022 Class A, Europe EN6100-3-2 / 3-3, Europe FCC Class A, USA ICES-003
Class A, Canada VCCI Class A, Japan CNS 13438, (BSMI-Taiwan) AS/NZ 3548
(C-tick), Australia Gost-R, Russia |
Immunity |
All European requirements EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, and EN300-386 |
Regulatory Markings |
CE, FCC, ICES-003, C-tick, VCCI, Gost-R BSMI, UL/cUL/S Mark, TUV-GS, MIC
|
Dimensions
and Weights |
Height |
190.5 cm (75 in) |
Width |
61 cm (24 in) |
Depth |
134.6 cm (53 in) |
Weight, main cabinet |
544.3 kg (1200 lbs) |
Power Cord |
(15 ft), (4.6 m) |
Clearance
and Service Access |
Front |
122 cm (48 in) |
Rear |
91.4 cm (36 in) |
Right |
0 clearance during operation* |
Left |
0 clearance during operation* |
* To access and remove side panels, allow approximately 2
ft (60 cm.) of space on the sides. For any peripheral tray in the processor
cabinet OVER 508 mm (20 in) in length, allow additional space for access
to the doors on the side where the peripheral will be loaded. |
|