| Processor |
| Number |
4 to 12 |
| Architecture |
UltraSPARC[tm] III Cu: 1200MHz
UltraSPARC IV: 1050MHz or 1350MHz, superscalar SPARC V9, ECC protected
UltraSPARC IV+: 1.5GHz or 1.8GHz superscalar SPARC V9, ECC protected |
| Cache per processor |
UltraSPARC IV:
Primary (L1): 64 KB 4-way data, 32 KB 4-way instruction, 2 KB Write, 2 KB
Prefetch
Secondary (L2): 16 MB external (exclusive access to 8 MB per pipeline), On-chip
controller and address tags
UltraSPARC IV+:
Primary (L2): 2 MB on-chip
Secondary (L3): 32 MB off-chip
|
| System Interconnect |
9.6-GB/sec. Sun Fireplane interconnect.
System bus with redundant data, address, and response crossbar interconnect. |
| System
Boards |
| Number of boards |
Up to 3 |
| CPU/Memory board |
4 CPUs with up to 64GB per board; maximum
12 processors per system. |
PCI I/O Assembly
PCI-X I/O Assembly
PCI+ I/O Assembly |
Up to 16 × PCI slots (12 at 33MHz and 4 at 33 or 66MHz)
Up to 16 × 64 bit PCI slots (12 at 33, 66 or 100MHz and 4 at 33MHz)
Up to 16 × 32 or 64 bit PCI slots (12 at 33 or 66MHz and 4 at 33MHz) |
| Main
Memory |
|
64 GB memory (max) per 4 CPUs on a CPU/Memory board, Up to 192 GB per
domain
Maximum system memory capacity of 192 GB (3 × 64GB)
|
| Standard
Interfaces |
| System Controller |
Responsible for the overall control of the
system. Each System Controller includes one RS-232/423 (DB25) serial interface
and one 10/100BASE-T ethernet/fast ethernet (RJ45) interface. Two per system. |
| Power
Supplies |
| 3 Fault-tolerant, redundant, hot swappable,
and hot pluggable power supplies |
| Environment |
| AC input |
200-240 VAC, 47-63 Hz, 16 A(per power cord) |
| Input power |
4180W @ 220V |
| Heat output |
14,260 BTUs/hr |
| Temperature |
Operating: 5° C to 35°
C (41° F to 95° F) - derate 2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140°
F) |
| Humidity |
Operating: 20% to 80% relative humidity,
noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
| Altitude |
Operating: 0 to 3,000 meters (0 to 10,000 feet)
Nonoperating: 0 to 12,000 meters (0 to 40,000 feet) |
| Acoustic noise |
69 dB(A) |
| Vibration |
Operating: 0.15 G's, 5 to 500Hz, swept-sine
Nonoperating: 1.5mm single amplitude/0.6 G's, 5 to 500Hz, swept-sine,
vertical 0.75mm single amplitude/0.3 G's, 5 to 500Hz, swept-sine, horizontal |
| Shock |
3 G's, 11 ms, half-sine |
| Number of cords |
3 (length each - 4.6 meter, 15.0 ft) |
Regulations
Meets or exceeds the following requirements: |
| RoHS Compliance Level |
RoHS:YL |
| Safety |
UL 60950, third-edition USA CAN/CSA-C22.2
No. 60950-00, Canada EN 60950, third-edition, Europe S Mark, Argentina Gost-R,
Russia CB Scheme with all national deviations |
| Emissions |
EN55022 Class A, Europe EN6100-3-2 / 3-3,
Europe FCC Class A, USA ICES-003 Class A, Canada VCCI Class A, Japan CNS
13438, (BSMI-Taiwan) AS/NZ 3548 (C-tick), Australia Gost-R, Russia |
| Immunity |
All European requirements EN55024, EN61000-4-2,
EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11,
and EN300-386 |
| Regulatory Markings |
CE, FCC, ICES-003, C-tick, VCCI, Gost-R
BSMI, UL/cUL/S Mark, TUV-GS, MIC |
| Dimensions
and Weights |
| Height |
Deskside: 82.3 cm (32.4 in)
Rackmount: 76.2 cm (30.0 in) |
| Width |
Deskside: 48.1 cm (18.9 in)
Rackmount: 44.6 cm (17.56 in) |
| Depth |
Deskside: 86.9 cm (34.2 in)
Rackmount: 72.4 cm (28.5 in) |
| Weight |
Deskside: 131.1 kg (289.0 lb)
Rackmount: 131.1 kg (289.0 lb) |
| Clearance
and Service Access |
| Front |
122 cm (48 in) |
| Rear |
91.4 cm (36 in) |
| Right |
0 clearance during operation |
| Left |
0 clearance during operation |
| Rack |
| Sun Fire Rack for Sun Fire E4900, SFE-XCAB |