Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] E2900, RoHS:YL Server: Hardware Specifications

Processor
Number 4, 8, or 12
Architecture UltraSPARC[tm] III Cu: 1.2GHz
UltraSPARC IV: 1.05GHz, 1200MHz or 1350MHz, superscalar SPARC V9, ECC protected
UltraSPARC IV+: 1.5GHz or 1.8GHz
Cache per processor Primary (L1): Parity protected 32KB instruction and 64KB data on chip (single-bit errors are corrected)
Secondary (L2): ECC-protected 16-MB external cache on UltraSPARC IV.
Level 3 cache per UltraSPARC IV+ processor: 32 MB shared external.
System Interconnect 9.6 GB/sec Sun Fireplane interconnect.
System bus with redundant data, address and response crossbar interconnect
System
CPU/Memory Boards Maximum of 3 CPU/Memory boards, with four processors each, and up to 64GB memory per board; maximum 12 processors per system
Bandwidth 9.6 GB/sec sustained bandwidth
31.2 GB/sec aggregate bandwidth
Main Memory
Maximum 64GB memory per 4 CPUs on a CPU/Memory board, up to 192GB maximum system memory capacity
Standard Interfaces
Alarm One alarm port (DB15)
Ethernet One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair port
(RJ-45) - Used for LOM/System Controller
Two 10/100/1000BASE-T Ethernet (copper) ports
PCI PCI Assembly: Six PCI slots via three buses. One 3.3V, 32/64-bit, 66MHz slot, Five 5V, 32/64-bit, 33MHz slots.
PCI+ Assembly: Six PCI slots via three buses. Six 3.3V, 32/64-bit, 66MHz slots.
PCI-X Assembly: Six PCI-X slots. 64-bit, 100MHz, 3.3V, (Integrated Ultra-320 SCSI controller)
Note:All (6) slots are short slots and cannot support long PCI cards.
Serial One RS-232/RS-423 asynchronous/synchronous serial port (RJ45), Serial A
(Serial B is reserved)
SCSI One Ultra3 SCSI 68-pin SCSI port
Single-ended (40MB/sec) or
LVD (160MB/sec)
Internal Mass Storage
Disks Two 73GB Ultra3-SCSI internal disks, 1.0 in., 10,000 RPM, or two 146GB Ultra-320 SCSI internal disks, 1.0 in., 10,000 RPM
DVD-ROM DVD-ROM internal drive
Tape DDS-4 or DAT72 tape drive (optional)
Power Supplies
Four power supplies providing 2N hot-pluggable redundancy; only two are required for the system to run.
Environment
AC input 200-240V single phase AC, 47-63Hz, with two 11/13 Amp circuits redundant with another two on a separate grid
Input power 3300W maximum
Heat output Base Configuration: 5250.64 BTU/hr
Maximum Configuration: 12683.38 BTU/hr
Temperature (operating) Optimal: 22° C (72° F)
Range: 5° C to 40° C (41° F to 104° F)
Humidity (operating) Optimal: 45% non-condensing
Range: 10% to 90% non-condensing humidity
Altitude Up to 3,048 meters (10,000 ft)
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety USA: UL 60950 3rd Edition
Canada: CAN/CSA C22.2 No. 60950-00
Europe: EN 60950 3rd Edition
Argentina: S Mark
Russia:Gost-R
CB Scheme with all national deviations
Emissions USA: FCC Class A
Canada: ICES-003 Class A
Europe: EN55022 Class A, EN6100-3-2/3-3
Japan: VCCI Class A
Taiwan: CNS-13438 BSMI
Australia: AS/NZ 3548 (C-tick)
Russia: Gost-R
Immunity All European requirements:
EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, and EN300-386
Regulatory markings CE, FCC, ICES-003, C-tick, VCCI, Gost-R
BSMI, UL/cUL/S Mark, TUV-GS, MIC
Dimensions and Weights
Height Chassis Only: 21.00 in (53.34 cm) / 12U
With Mounting Cradle: 25.30 in (64.21 cm)
With Wooden Pallet: 36.97 in (93.90 cm)
Width Chassis Only: 17.50 in (44.50 cm)
With Mounting Cradle: 22.20 in (56.48 cm)
With Wooden Pallet: 23.62 in (60.00 cm)
Depth System Only: 22.00 in (55.80 cm)
Including Slides: 22.40 in (56.80 cm)
With Mounting Cradle: 22.00 in (55.82 cm)
With Wooden Pallet: 27.76 in (70350 cm)
Weight System Only: 236.0 lbs (107 kg)
With Mounting Cradle: 286.0 lbs (130 kg)
With Cable Mgmt & Slides: 310.0 lbs (141 kg)
Clearance and Service Access
Front 35 in (86cm)
Rear 35 in (86cm)
Refer to the Sun Fire E2900 Site Planning Guide (817-4052) for clearance and service access details.
Racking
All Sun racks and most third party; 24 in. (600mm) and deeper racks; 2 per 4-post rack, 1 per 2-post rack

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback