Sun StorEdge[tm] 9990 System, RoHS:YL: Hardware Specifications

Number of disk drives (with spares) 5 to 1152
Hot spares (maximum) 1 - 40
Individual disk capacities 72GB (15K RPM)
72GB (15K RPM)
146GB (10K RPM)
146GB (15K RPM)
300GB (10K RPM)
300GB (15K RPM)
Total raw capacity per system (72GB drive) 72GB x 1152 = 82.944TB*
Total raw capacity per system (146GB drive) 146GB x 1152 = 168.192TB*
Total raw capacity per system (300GB drive) 300GB x 1152 = 345.6TB*
* This is total raw capacity, using 1152 disk drives (maximum), with no spare drives.
Maximum 128GB
Minimum 4GB
Increments 4GB
Up to 6GB
Up to 16,384
Number of Front End Directors 6
Number of Simultaneous Data Transfers Up to 16 or 32 per Front End Director
Interface speed (fibre channel) 2 GB/sec
Number of Back End Directors Up to 4
Disk Drives per Back End Directors Up to 256 Hard Disk Drives
Fibre Channel (fiber-optic cable) 32, 64, 96, 128, 160, 192
ESCON 16, 32, 64, 80, 96
FICON 8, 16, 24, 32, 40, 48
Bandwidth
Per fully configured system
81GB/sec aggregate system bandwidth (consisting of 68GB/sec data bandwidth, and 13GB/sec control bandwidth)
Power Control Frame: 9.077 kVA
Array Frame: 7.636 kVA
Heat Control Frame: 8.68 kW
Array Frame: 7.07 kW
Height Control Frame (DKC): 186.0 cm (73.2 in.)
Array Frame (DKU): 186.0 cm (73.2 in.)
Width Control Frame (DKC): 78.2 cm (30.77 in.)
Array Frame (DKU): 65.0 cm (25.59 in.)
Depth Control Frame (DKC): 92.5 cm (36.42 in.)
Array Frame (DKU): 92.5 cm (36.42 in.)
Weight Control Frame (DKC): 590. kg (1300.73 lb.)
Array Frame (DKU): 430.0 (947.99 lb.)
Geography Power Quantity Plug Connector (inline)
US Single-Phase: 30-Amp
4
Thomas & Betts 3750 DP Thomas & Betts 3933
Single-Phase: 50-Amp
2
Thomas & Betts 9P53U2 Thomas & Betts 9C53U2 or 9R53U2W
3-Phase: 30-Amp
2
Thomas & Betts 3760PDG or DDK 115J-AP8508 Thomas & Betts 3934
Europe Single-Phase: 30-Amps
4
N/A (Hardwire) N/A (Hardwire)
Single-Phase: 50-Amps
2
N/A (Hardwire) N/A (Hardwire)
3-Phase: 30-Amp
2
N/A (Hardwire) N/A (Hardwire)
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.