Processor |
Number |
2 or 4 Quad-Core or 6-Core |
Architecture |
Type: AMD Opteron
- Quad-Core AMD Opteron 2356 (2.3 GHz, 75W)
- Quad-Core AMD Opteron 8356 (2.3 GHz, 75W)
- Six-Core AMD Opteron 8435 (2.6 GHz, 75W)
|
Cache memory |
512 KB Level 2 cache per processor core (Quad Core) |
Main Memory |
Capacities |
DIMM slots per System: 32
DIMM type: DDR2 667MHz Registered DIMMs
DIMM size: 2-GB or 4-GB
Maximum capacity: 128GB (when configured with 4-GB DIMMs)
NOTE: For optimal performance,
install DIMMs in matched pairs. DIMM fillers should be installed in all unoccupied DIMM slots.
|
Standard
Integrated Interfaces |
Network |
Four 10/100/1000 Base-T Ethernet Ports
|
Network Management |
One dedicated 10/100Base-T Ethernet port |
Serial Management |
One dedicated TIA/EIA-232-F asynchronous RJ45 port |
USB |
Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port |
PCI Expansion Slots |
Six internal MD2 low profile PCI Express slots
- One PCIe x16 slot
- Four PCIe x8 slot
- One PCIe x4 slot (x8 mechanical)
|
Internal Mass Storage |
7410 (SAS 2.0) Disks |
Up to eight 2.5" 500GB 7200 RPM or 500GB 5400 RPM SATA internal hot-swap Disks
|
Disk Shelf 24x3.5" SAS-2 Disks |
Up to twenty-four 3.5" 1TB 7200 RPM, 2TB 7200 RPM SAS Disks or 18GB SAS Solid State Drives
|
Power Supplies |
Dual redundant, hot swappable power supplies
(Power supply rating DC output = 1050W)
(UL Maximum AC input = 12 Amps RMS at 100 VAC)
|
Environment |
AC power |
90-264 V AC (47-63 Hz) |
Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing
Nonoperating: up to 93% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: up to 3048 m (10,000 ft.), maximum ambient
temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.) |
Acoustic noise |
Single, non-rack system:
LwAd (1B=10dB)
7.7 B (idle and operating)
LpAm bystander
65.8 dB at max ambient
|
Regulations
Meets or exceeds the following
requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
IEC 60950, UL/CSA 60950-1, EN 60950, CB Scheme with all country
differences |
RFI/EMI |
FCC CFR 47 Part 15 Class A, EN 55022 Class A, EN 61000-3-2,
EN 61000-3-3, EN300-386 |
Immunity |
EN55024, EN300-386 |
Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
|
Dimensions and Weight |
Height |
87.85 mm (3.46 in.) |
Width |
425.46 mm (16.75 in.) |
Depth |
711.25 mm (28 in.) |
Weight |
28.6 kg (63 lb.) maximum without rack kit
|
Rack Mounting |
Sun Storage 7410 (SAS 2.0) and Disk Shelf 24x3.5" SAS-2 racks |
Racks are as follows:
- Sun Rack 938
- Sun Rack 1038
- Sun Rack 1042
- Third Party EIA-310-D-1992
|