Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Storage 7410: Hardware Specifications

Processor
Number 2 or 4 Quad-Core
Architecture Type: AMD Opteron
  • Quad-Core AMD Opteron 2356 (2.3 GHz, 75W)
  • Quad-Core AMD Opteron 8356 (2.3 GHz, 75W)
  • Six-Core AMD Opteron 8435 (2.6 GHz, 75W)
Cache memory 512 KB Level 2 cache per processor core (Quad Core)
Main Memory
Capacities DIMM slots per System: 32
DIMM type: DDR2 667MHz Registered DIMMs
DIMM size: 2-GB or 4-GB
Maximum capacity: 128GB (when configured with 4-GB DIMMs)
NOTE: For optimal performance, install DIMMs in matched pairs. DIMM fillers should be installed in all unoccupied DIMM slots.
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port
PCI Expansion Slots Six internal MD2 low profile PCI Express slots
  • One PCIe x16 slot
  • Four PCIe x8 slot
  • One PCIe x4 slot (x8 mechanical)
Internal Mass Storage
7410 Disks Up to eight 2.5" 1TB 7200 RPM SATA internal hot-swap Disks
J4400 Expansion Array Disks Up to twenty-four 3.5" 1TB 7200 RPM SATA Disks
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating DC output = 1050W)
(UL Maximum AC input = 12 Amps RMS at 100 VAC)
Environment
AC power 90-264 V AC (47-63 Hz)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing
Nonoperating: up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: up to 3048 m (10,000 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Acoustic noise Single, non-rack system:
LwAd (1B=10dB)
     7.7 B (idle and operating)
LpAm bystander
     65.8 dB at max ambient
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety IEC 60950, UL/CSA 60950-1, EN 60950, CB Scheme with all country differences
RFI/EMI FCC CFR 47 Part 15 Class A, EN 55022 Class A, EN 61000-3-2, EN 61000-3-3, EN300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Dimensions and Weight
Height 87.85 mm (3.46 in.)
Width 425.46 mm (16.75 in.)
Depth 711.25 mm (28 in.)
Weight 28.6 kg (63 lb.) maximum without rack kit
Rack Mounting
Sun Storage 7410 and J4400 expansion array racks Racks are as follows:
  • Sun Rack 938
  • Sun Rack 1038
  • Sun Rack 1042
  • Third Party EIA-310-D-1992

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback