Disks
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
XTA7410-LOGZ18GB
[S]
|
540-7754 [C]
|
18GB Solid State Drive SATA Assembly |
n/a |
|
- 18GB Solid State Drive, SATA Interface,
|
n/a |
|
- Disk Drive Mounting Bracket,
|
n/a |
XTA7410-READZ100G
[S]
|
540-7793 [C]
|
100GB Solid State Drive SATA Assembly |
n/a |
|
- 100GB Solid State Drive, SATA Interface,
|
n/a |
|
|
n/a |
n/a |
540-7594 4
5 6
[C]
|
1TB - 7.2K RPM SATA Disk Assembly with brackets and 1 of the following disks,
|
n/a |
|
- Hitachi HUA721010KLA330 [HUA7210SASUN1.0T]
(1TB - 7200 RPM - SATA Disk)
|
n/a |
|
- Seagate ST31000340NS [ST31000NSSUN1.0T]
(1TB - 7200 RPM - SATA Disk)
|
n/a |
|
|
n/a |
|
- Disk Drive Mounting Bracket,
|
n/a |
n/a |
540-7711 [C]
|
500GB - 5400 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks:, |
n/a |
|
- Hitachi HTE545050KTA300 [HTE5450SASSUN500G]
(500GB - 5400 RPM - SATA Disk),
|
n/a |
|
|
n/a |
n/a |
540-7910 10
[C]
|
1TB - 7.2K RPM SATA Disk Assembly with brackets and 1 of the following disks, |
540-7594 7
8 9
[C]
|
|
- Seagate ST31000340NS [ST31000NSSUN1.0T]
(1TB - 7200 RPM - SATA Disk)
|
n/a |
|
|
n/a |
|
- Disk Drive Mounting Bracket,
|
n/a |
n/a |
542-0184 [C]
|
500GB - 7200 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks:, |
n/a |
|
- Seagate ST9500530NS [ST95000NSSUN500G]
(500GB - 7200 RPM - SATA Disk)
|
n/a |
|
|
n/a |
3 Disk Drive Assembly PN#540-7910 is used in the J4400 expansion array as part of the Sun Storage 7410.
4 540-7910 is the only approved CRU for 1TB 7.2K SATA disks on Storage 7410. Replacements for 540-7594 should order 540-7910 instead.
5 Disk 390-0381 was removed from Assembly 540-7594-01 in January 2009.
(WO_40642)
6 Disk Drive Assembly PN#540-7594 was used in the J4400 expansion array as part of the Sun Storage 7410.
7 540-7910 is the only approved CRU for 1TB 7.2K SATA disks on Storage 7410. Replacements for 540-7594 should order 540-7910 instead.
8 Disk 390-0381 was removed from Assembly 540-7594-01 in January 2009.
(WO_40642)
9 Disk Drive Assembly PN#540-7594 was used in the J4400 expansion array as part of the Sun Storage 7410.
10 Disk Drive Assembly PN#540-7910 is used in the J4400 expansion array as part of the Sun Storage 7410.
NOTE: The Sun Storage 7410 has shipped with Disk Assemblies PN#540-7594 and PN#540-7910 installed, however PN#540-7910 is the only approved CRU and must be used for replacement for either part number.
NOTE: 540-7594 was replaced by 540-7910 in December 2008 by wo_40354.
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
|