Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun ZFS Storage 7120: Hardware Specifications

Processor
Number 1 to 2 Intel Quad-Core
Architecture Type: Intel Xeon Quad-Core Processor
CPUs Intel Xeon 2.40 GHz Quad-Core E5620 (12MB L3, 80W)
Main Memory
Capacities Total DIMM slots: 18
DIMM type: DDR3 1333MHz Registered DIMMs
DIMM size: 4-GB 1333MHz
Maximum capacity: 72GB (when fully populated with 4-GB DIMMs)
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port
PCI Expansion Slots Four internal MD2 low profile 8-lane PCI Express slots (all with x8 mechanical connectors)
Internal Mass Storage
Disks SAS: Configurations of Up to 12 internal 3.5" SAS HDDs with add-on SAS Host Bus Adapter
SATA: Up to 2 internal 2.5" SATA HDDs using the rear 2-Slot HDD assembly
Drive Type
Density
Speed
Form Factor
SAS
1 TB
7,200 RPM
3.5"
SAS
2 TB
7,200 RPM
3.5"
SATA
500 GB
7,200 RPM
2.5"
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 1200W)
(UL Maximum AC input = 1200W x 1.33 efficiency = 1596W)
(13.0 Amps Max current AC RMS)
Environment
AC power 100-120/200-240 V AC, (50-60 Hz)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3048 m (10000 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: Up to 12,000 m (40,000 ft.)
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety UL/cUL, CE, BSMI, GOST-R, S-Mark, CSA C22.2 No. 60950-03
RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Other Complies with WEEE Directive (2002/96/EC) and RoHS Directive (2002/95/EC)
Dimensions and Weight
Height 87.12 mm (3.43 in.)
Width 425.45 mm (16.75 in.)
Depth 762.0 mm (30 in.)
Weight 29.54 kg (65 lb.)
Rack Mounting
Sun ZFS Storage 7120 Racks Racks are as follows:
  • Sun Rack II 1042 (Redwood)
  • Sun Rack II 1242 (Redwood)

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback