Processor |
Number |
1 Quad-Core |
Architecture |
Type: AMD Opteron Quad-Core Processor |
CPUs |
AMD 1.9GHz Quad-Core Opteron 2347 HE
|
Cache memory |
2x512KB Level 2 and 1MB Level 3 for Quad-Core |
Main Memory |
Capacities |
Total DIMM slots: 16 slots on the system board (12 slots are not populated)
DIMM type: PC2-5300 DDR2 667MHz Registered DIMMs (128 bit plus ECC databus)
DIMM size: 2-GB
Maximum capacity: 8GB (when configured with 2-GB DIMMs)
NOTE: All DIMMs must be the same density. Slots D4,D5,D6, and D7 are
populated in the 4 x 2GB configuration.
|
Standard
Integrated Interfaces |
Network |
Four 10/100/1000 Base-T Ethernet Ports
|
Network Management |
One dedicated 10/100Base-T Ethernet port |
Serial Management |
One dedicated TIA/EIA-232-F asynchronous RJ45 port |
SAS |
Four channel SAS interface, internal access only. |
USB |
Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port |
PCI Expansion Slots |
Six internal MD2 low profile 8-lane PCI Express slots
(1x 16-lane, 4x 8-lane, 1x 4-lane) |
Internal Mass Storage |
Disks |
SAS: 16 x 2.5" 146GB or 300GB - 10000 RPM SAS Disks
|
Power Supplies |
Dual redundant, hot swappable power supplies
(Power supply rating DC output = 1050W)
(UL Maximum AC input = 1050W x 1.33 efficiency = 1397W)
(12 Amps RMS at 100 VAC)
|
Software |
Features |
DTrace Analytics
ZFS Hybrid Storage Pool
Remote Replication of data for Disaster Recovery
Unlimited Read-only and Read-write Snapshots, with Snapshot Schedules
Built-in Data Compression
Thin Provisioning of iSCSI LUNs
Virus Scanning and Quarantine
NDMP Backup and Restore
Phone-Home of Telemetry for all Software and Hardware Issues
|
Environment |
AC power |
100-200/200-240 V AC (50-60 Hz) |
Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to
149° F)
|
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
38° C (100.4° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: up to 3000 m (9843 ft.), maximum ambient
temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.) |
Acoustic noise |
Single, non-rack system:
LwAd (1B=10dB)
6.8 B at max ambient
LpAm bystander
53 dB at max ambient
|
Regulations
Meets or exceeds the following
requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country
differences |
RFI/EMI |
FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2,
EN61000-3-3, EN 300-386 |
Immunity |
EN55024, EN300-386 |
Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
|
Dimensions and Weight |
Height |
88 mm (3.49 in.) |
Width |
426 mm (16.75 in.) |
Depth (not including PSU handle) |
714 mm (28.125 in.) |
Depth (including PSU handle) |
736.4 mm (28.99 in.) |
Weight |
25.75 kg (56.77 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
|
Rack Mounting |
Sun Storage 7110 Unified Storage System Racks |
Racks are as follows:
- Sun Rack 900
- Sun Rack 1000-38
- Sun Rack 1000-42