73GB 15K, FC |
146GB 10K, FC |
400GB 10K, FC |
146GB 15K, FC |
300GB 10K, FC |
300GB 15K, FC |
450GB 15K, FC |
500GB 7.2K, SATA |
600GB 15K, FC |
750GB 7.2K, SATA |
1TB 7.2K, SATA |
Characteristics for this array include:
- Controller tray: Dual RAID controllers in a 4RU chassis
Note: There are no disk drives installed within this tray.
- Expansion tray: Five to sixteen hard disk drives per tray (3RU chassis)
- Supports RAID 0, 1, 3, 5, and 1+0
- Rack mountable
|
Capacity |
Up to 16 Disk drives per array
|
73.4GB Disk drives |
16 x 73.4 = 1.1744TB |
146.8GB Disk drives |
16 x 146.8 = 2.3488TB |
300GB Disk drives |
16 x 300 = 4.8TB |
450GB Disk drives |
16 x 450 = 7.2TB |
500GB Disk drives |
16 x 500 = 8.0TB |
750GB Disk drives |
16 x 750 = 12.0TB |
Total capacity depends on the following:
- Number of expansion trays attached to a controller tray
- Up to fourteen expansion trays can be attached to a controller tray
- Mount a controller tray and 11 expansion trays in one rack
- Mount 3 additional expansion trays in a second rack
- A controller tray has no (0, zero) disk drives installed within its chassis
- Example of available storage using a controller tray and:
- 300GB FC drives in 11 expansion trays - total raw capacity =
52.8TB (16 x 300GB = 4.8TB x 11 = 52.8TB)
- 500GB SATA drives in 14 expansion trays - total raw capacity =
112.0TB (16 x 500GB = 8.0TB x 14 = 112.0TB)
Note 1: Total raw capacity decreases depending on RAID level and number of spares used within each array
configuration.
Note 2: The array configuration supports up to 15 global hot spare drives; each spare can be used for any
disk in the array configuration.
|
|
AC input |
Controller Tray
- 2.65A Max Operating @ 240 VAC (180 – 264 VAC Range), 50/60 Hz
Expansion Tray
- 1.97A Max Operating @ 240 VAC (180 – 264 VAC Range), 50/60 Hz
|
Power and cooling |
Dual hot-swappable redundant 400W power supplies and fan modules
(power and fan modules are enclosed in one unit) |
Heat output |
Controller Tray - 235W (804 BTU/hr)
Expansion Tray - 444W (1517 BTU/hr)
|
Temperature |
Controller Tray
- Operating: 10° C to 40° C (50° F to 104° F)
- Storage: -10° C to 50° C (-14° F to 120° F)
- Transit: -40° C to 60° C (-40° F to 140° F)
Expansion Tray
- Operating: 10° C to 40° C (50° F to 104° F)
- Storage: -10° C to 50° C (-14° F to 120° F)
- Transit: -40° C to 60° C (-40° F to 140° F)
|
Humidity |
Controller tray and expansion tray specifications are the same:
- Operating: 10% to 90%, noncondensing
- Nonoperating: 10% to 90%, 10% per hour Gradient
|
Altitude |
Controller tray and expansion tray specifications are the same:
- Operating: 30.5 m to 3000 m (100 ft to 9840 ft)
- Nonoperating: 30.5 m to 12000 m (100 ft to 40000 ft)
|
Vibration |
Controller tray and expansion tray specifications are the same:
- Operating: 0.20 G, 5 to 500 Hz sinusoidal
- Nonoperating: 1.0 G, 5 to 500 Hz sinusoidal
|
Shock |
Controller tray and expansion tray specifications are the same:
- Operating: 5.0 g, 11 ms half sinewave
- Nonoperating:
- 5 G, 11 msec half sinewave in the front/back directions
- 30 G, 11 msec half sinewave in the side/side and up/down directions
|
|
RoHS Compliance Level |
RoHS:YL
|
Immunity |
CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC
61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
|
Safety and Emissions |
IEC 60950, EN 60950, UL 60950, UL 1950, FCC Part 15 (47CFR15B),
CISPR 22 (EN55022 - RF Radiated and Conducted Emissions), IEC 61000-3-2, IEC 61000-3-3
|
|
Height |
- Controller Tray: 17.5 cm (6.9 in)
- Expansion Tray: 12.95 cm (5.1 in)
|
Width |
- Controller Tray: 48.3 cm (19.0 in)
- Expansion Tray: 44.70 cm (17.6 in)
|
Depth |
- Controller Tray: 63.0 cm (24.8 in)
- Expansion Tray: 57.15 cm (22.5 in)
|
Weight |
- Controller Tray: 36.5 kg (80.5 lbs)
- Expansion Tray: 38.5 kg (85.0 lbs)
|
|
Height |
188 cm (74 in)
|
Width |
59.7 cm (23.5 in) |
Depth |
100 cm (39.4 in) |
Weight |
Specifications are as follows:
- Empty: 163.3 kg (360 lbs)
- Fully loaded: 737.0 kg (1625 lbs)
|