146GB 15K, FC |
300GB 15K, FC |
450GB 15K, FC |
500GB 7.2K, SATA |
600GB 15K, FC |
1TB 7.2K, SATA |
Characteristics for this array include:
- Dual RAID controllers
- 4GB of battery-backed cache
- Four or Eight 8 Gb/s FC host connections per controller
- Five to sixteen hard disk drives per tray
- Supports RAID 0, 1, 3, 5, 6 (p + q) and 10
- Rack mountable
- Small 3 RU chassis
|
Capacity |
Up to 16 Disk drives per array
|
146.8GB Disk drives |
16 x 146.8 = 2.3488TB |
300GB Disk drives |
16 x 300 = 4.8TB |
450GB Disk drives |
16 x 450 = 7.2TB |
500GB Disk drives |
16 x 500 = 8.0TB |
1TB Disk drives |
16 x 1 = 16.0TB |
Total capacity depends on the following:
- Number of expansion trays added to a controller tray
- Up to three CSM200 expansion trays can be added to a controller tray
(with 4GB cache and 4 Host Ports)
- Up to six CSM200 expansion trays can be added to a controller tray
(with 4GB cache and 8 Host Ports)
- A controller tray and six expansion trays provide 112 disk
drives (7 trays x 16 disk drives)
- Example of available storage:
- 300GB FC disk drives - total raw capacity = 33.6TB (112 x
300GB)
- Sixteen 300GB FC drives in controller tray and ninety-six
500GB SATA drives in expansion trays - total raw capacity =
52.8TB (16 x 300GB + 96 x 500GB)
Note 1: Total raw capacity decreases depending on RAID level and number
of spares used within each array configuration.
Note 2: The array configuration supports up to 15 global hot spare
drives; each spare can be used for any disk in the array configuration.
|
|
AC input |
- 4.4 A Max Operating @ 100 VAC (90 – 136 VAC Range), 50/60
Hz
- 1.9 A Max Operating @ 240 VAX (198 – 264 VAC Range), 50/60
Hz
|
DC input |
17 A Max Operating (-36 to -72 V DC Range) |
Power and cooling |
Dual hot-swappable redundant 620W power supplies
and fan modules
(power and fan modules are enclosed in one unit) |
Heat output |
1380 BTU/hr * |
Temperature |
- Operating:
10° C to 40° C (50° F to 104° F) (without battery)
10° C to 35° C (50° F to 95° F) (with battery)
- Non-Operating (Storage):
-10° C to 50° C (-14° F to 120° F) (without battery)
-10° C to 45° C (-14° F to 113° F) (with battery
- 3 month max.)
- Non-Operating (Transit):
-40° C to 60° C (-40° F to 140° F) (without
battery)
-40° C to 60° C (-40° F to 140° F) (with battery
- 1 week max.)
|
Humidity |
- Operating:
20% to 80%, noncondensing
- Nonoperating (Storage):
10% to 90%, Max Dew Point 26° C (79° F), 10% per hour
Gradient
- Nonoperating (Transit):
5% to 95%, Max Dew Point 26° C (79° F), 10% per hour Gradient
|
Altitude |
- Operating: 30.5 m (100 ft) below sea level to 3000 m
(9840 ft)
- Nonoperating: 30.5 m (100 ft) below sea level to 12000
m (40000 ft)
|
Vibration |
0.20 G, 5 to 500 Hz sinusoidal |
Shock |
- Operating:
10 G, 3.75 ms half triangular
- Nonoperating:
30 G, 11 ms half sinewave in the side / side and up / down directions
5 G, 11 ms half sinewave in the front / back direction
|
* - Based on a configuration of two
power supplies, two expansion trays, and 16 drives |
|
Meets or exceeds
the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Immunity |
CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3,
IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-11 |
Safety and Emissions |
IEC 60950, EN 60950, UL/CSA 60950, FCC Part 15
(47CFR15B), CISPR 22 (EN55022 - RF Radiated and Conducted Emissions),
IEC 61000-3-2, IEC 61000-3-3 |
|
Height |
12.95 cm (5.1 in) |
Width |
48.28 cm (19 in) |
Depth |
57.15 cm (22.5 in) |
Weight |
43 kg (95 lbs) Max. |
Clearance and Service Access
|
Front |
76.2 cm (30 in) |
Rear |
60.96 cm (24 in) |
Airflow for cooling is from front to rear. |