Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun[tm] Storage 6180 Array: Hardware Specifications

Disks
146GB 15K, FC
300GB 15K, FC
450GB 15K, FC
500GB 7.2K, SATA
600GB 15K, FC
1TB 7.2K, SATA
Characteristics for this array include:
  • Dual RAID controllers
    • 4GB of battery-backed cache
    • Four or Eight 8 Gb/s FC host connections per controller
  • Five to sixteen hard disk drives per tray
  • Supports RAID 0, 1, 3, 5, 6 (p + q) and 10
  • Rack mountable
  • Small 3 RU chassis
Capacity
Up to 16 Disk drives per array
146.8GB Disk drives 16 x 146.8 = 2.3488TB
300GB Disk drives 16 x 300 = 4.8TB
450GB Disk drives 16 x 450 = 7.2TB
500GB Disk drives 16 x 500 = 8.0TB
1TB Disk drives 16 x 1 = 16.0TB
Total capacity depends on the following:
  • Number of expansion trays added to a controller tray
  • Up to three CSM200 expansion trays can be added to a controller tray (with 4GB cache and 4 Host Ports)
  • Up to six CSM200 expansion trays can be added to a controller tray (with 4GB cache and 8 Host Ports)
  • A controller tray and six expansion trays provide 112 disk drives (7 trays x 16 disk drives)
  • Example of available storage:
    • 300GB FC disk drives - total raw capacity = 33.6TB (112 x 300GB)
    • Sixteen 300GB FC drives in controller tray and ninety-six 500GB SATA drives in expansion trays - total raw capacity = 52.8TB (16 x 300GB + 96 x 500GB)
Note 1: Total raw capacity decreases depending on RAID level and number of spares used within each array configuration.

Note 2: The array configuration supports up to 15 global hot spare drives; each spare can be used for any disk in the array configuration.
Environment
AC input

 

  • 4.4 A Max Operating @ 100 VAC (90 – 136 VAC Range), 50/60 Hz
  • 1.9 A Max Operating @ 240 VAX (198 – 264 VAC Range), 50/60 Hz
DC input 17 A Max Operating (-36 to -72 V DC Range)
Power and cooling Dual hot-swappable redundant 620W power supplies and fan modules
(power and fan modules are enclosed in one unit)
Heat output 1380 BTU/hr *
Temperature
  • Operating:
    10° C to 40° C (50° F to 104° F) (without battery)
    10° C to 35° C (50° F to 95° F) (with battery)
  • Non-Operating (Storage):
    -10° C to 50° C (-14° F to 120° F) (without battery)
    -10° C to 45° C (-14° F to 113° F) (with battery - 3 month max.)
  • Non-Operating (Transit):
    -40° C to 60° C (-40° F to 140° F) (without battery)
    -40° C to 60° C (-40° F to 140° F) (with battery - 1 week max.)
Humidity
  • Operating:
    20% to 80%, noncondensing
  • Nonoperating (Storage):
    10% to 90%, Max Dew Point 26° C (79° F), 10% per hour Gradient
  • Nonoperating (Transit):
    5% to 95%, Max Dew Point 26° C (79° F), 10% per hour Gradient
Altitude
  • Operating: 30.5 m (100 ft) below sea level to 3000 m (9840 ft)
  • Nonoperating: 30.5 m (100 ft) below sea level to 12000 m (40000 ft)
Vibration 0.20 G, 5 to 500 Hz sinusoidal
Shock
  • Operating:
    10 G, 3.75 ms half triangular
  • Nonoperating:
    30 G, 11 ms half sinewave in the side / side and up / down directions
    5 G, 11 ms half sinewave in the front / back direction
* - Based on a configuration of two power supplies, two expansion trays, and 16 drives
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Immunity CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-11
Safety and Emissions IEC 60950, EN 60950, UL/CSA 60950, FCC Part 15 (47CFR15B), CISPR 22 (EN55022 - RF Radiated and Conducted Emissions), IEC 61000-3-2, IEC 61000-3-3
Dimensions and Weights
Height 12.95 cm (5.1 in)
Width 48.28 cm (19 in)
Depth 57.15 cm (22.5 in)
Weight 43 kg (95 lbs) Max.
Clearance and Service Access
Front 76.2 cm (30 in)
Rear 60.96 cm (24 in)
Airflow for cooling is from front to rear.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback