Sun StorageTek[tm] 6140 Array, RoHS:YL: Hardware Specifications
|
73GB 15K, FC |
146GB 10K, FC |
400GB 10K, FC |
146GB 15K, FC |
300GB 10K, FC |
300GB 15K, FC |
450GB 15K, FC |
500GB 7.2K, SATA |
600GB 15K, FC |
750GB 7.2K, SATA |
1TB 7.2K, SATA |
Characteristics for this array include:
- Dual RAID controllers
- 2GB or 4GB of battery-backed cache
- Four 4 Gb/s FC host connections per controller
- Five to sixteen hard disk drives per tray
- Supports RAID 0, 1, 3, 5, and 1+0
- Rack mountable
- Small 3 RU chassis
|
Capacity |
Up to 16 Disk drives per array
|
73.4GB Disk drives |
16 x 73.4 = 1.1744TB |
146.8GB Disk drives |
16 x 146.8 = 2.3488TB |
300GB Disk drives |
16 x 300 = 4.8TB |
450GB Disk drives |
16 x 450 = 7.2TB |
500GB Disk drives |
16 x 500 = 8.0TB |
1TB Disk drives |
16 x 1 = 16.0TB |
Total capacity depends on the following:
- Number of expansion trays added to a controller tray
- Up to three expansion trays can be added to a controller tray
(with 2GB cache)
- Up to six expansion trays can be added to a controller tray
(with 4GB cache)
- A controller tray and six expansion trays provide 112 disk
drives (7 trays x 16 disk drives)
- Example of available storage:
- 300GB FC disk drives - total raw capacity = 33.6TB (112 x
300GB)
- Sixteen 300GB FC drives in controller tray and ninety-six
500GB SATA drives in expansion trays - total raw capacity =
52.8TB (16 x 300GB + 96 x 500GB)
Note 1: Total raw capacity decreases depending on RAID level and number
of spares used within each array configuration.
Note 2: The array configuration supports up to 15 global hot spare
drives; each spare can be used for any disk in the array configuration.
|
|
AC input |
Controller Tray
- 4.4 A Max Operating @ 100 VAC (90 – 136 VAC Range), 50/60
Hz
- 1.9 A Max Operating @ 240 VAC (198 – 264 VAC Range), 50/60
Hz
Expansion Tray
- 4.3 A Max Operating @ 100 VAC (90 – 136 VAC Range), 50/60
Hz
- 1.7 A Max Operating @ 240 VAC (198 – 264 VAC Range), 50/60
Hz
|
DC input |
-48V DC/ NEBS redundant power supplies |
Power and cooling |
Dual hot-swappable redundant 400W power supplies
and fan modules
(power and fan modules are enclosed in one unit) |
Heat output |
Controller Tray - 1459.0 BTU/hr (max)
Expansion Tray - 1380.6 BTU/hr (max) |
Temperature |
Controller Tray
- Operating: 10° C to 35° C (50° F to 95°
F)
- Storage (without battery): -10° C to 50° C (-14°
F to 120° F)
- Storage (with battery 3 month maximum): -10° C to
45° C (-14° F to 113° F)
Expansion Tray
- Operating: 10° C to 35° C (50° F to 95°
F)
- Storage: -10° C to 50° C (-14° F to 120°
F)
|
Humidity |
Controller tray and expansion tray specifications
are the same:
- Operating: 20% to 80%, noncondensing
- Nonoperating: 10% to 90%, 10% per hour Gradient
|
Altitude |
Controller tray and expansion tray specifications
are the same:
- Operating: 30.5 m (100 ft) below sea level to 3000 m
(9840 ft)
- Nonoperating: 30.5 m (100 ft) below sea level to 12000
m (40000 ft)
|
Vibration |
Controller tray and expansion tray specifications
are the same:
- Operating: Random vibration to specified power spectral
density
- Nonoperating: .5 G, 5 to 150 Hz sinusoidal
|
Shock |
Controller tray and expansion tray specifications
are the same:
- Operating: 10g, 3.75 ms half triangular
- Nonoperating: 20 G, 8.0 msec square wave in each direction
along x, y, and z axis
|
|
Meets or exceeds
the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Immunity |
CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3,
IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-11 |
Safety and Emissions |
IEC 60950, EN 60950, UL/CSA 60950, FCC Part 15
(47CFR15B), CISPR 22 (EN55022 - RF Radiated and Conducted Emissions),
IEC 61000-3-2, IEC 61000-3-3 |
|
Height |
12.95 cm (5.1 in) |
Width |
44.70 cm (17.6 in) |
Depth |
57.15 cm (22.5 in) |
Weight |
Specifications are as follows:
- Controller Tray: 40.0 kg (88 lbs)
- Expansion Tray: 38.5 kg (85 lbs)
|
|
|