Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorageTek 5800

Codename: Honeycomb 1.1

Serial Number Location Front, bottom of rack above the anti-tip bar



XT-5808-20AMCB XT-5816-20AMCB
594-3520-01
594-3520-02
1 Rackmounted 8-Node ST5800
1 Sun Fire X2100 Service Processor
2 Gigabit Ethernet Switches
32 500GB 7200 RPM Disks
594-3521-01
594-3521-02
1 Rackmounted 16-Node ST5800
1 Sun Fire X2100 Processor
2 Gigabit Ethernet Switches
64 500GB 7200 RPM Disks
XT-5808-20AMCB XT-5816-20AMCB
594-3520-03
1 Rackmounted 8-Node ST5800
1 Sun Fire X2100 M2 Service Processor
2 Gigabit Ethernet Switches
32 500GB 7200 RPM Disks
594-3520-03
1 Rackmounted 16-Node ST5800
1 Sun Fire X2100 M2 Processor
2 Gigabit Ethernet Switches
64 500GB 7200 RPM Disks
XT-5808-20AMCBZ XT-5816-20AMCBZ
594-3520-03
1 Rackmounted 8-Node ST5800
1 Sun Fire X2100 M2 Service Processor
2 Gigabit Ethernet Switches
32 500GB 7200 RPM Disks
594-3521-03
1 Rackmounted 16-Node ST5800
1 Sun Fire X2100 M2 Processor
2 Gigabit Ethernet Switches
64 500GB 7200 RPM Disks
XT-5832-20AMCBZ
594-4516-02
1 Rackmounted 16-Node ST5800
2 Sun Fire X2100 M2 Service Processors
4 Gigabit Ethernet Switches
128 500GB 7200 RPM Disks



Table Legend
[F] = Field Replaceable Unit (FRU)

PART # DESCRIPTION
F570-1144 [F]
300-1969
380-1384 [F]
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
541-1863 [F]
541-1636
370-7943
370-7944
541-1202
Disk Node FRU without Disk Drives
Power Supply 1
Disk Node Chassis Assembly 1
Tyan S2865 Motherboard with 2.2GHz Opteron 148
Heatsink and Air Baffle 343745400004
Tyan M3290 Service Processor
FDK CR2032 Battery
Tyan M1204 4-Slot Disk Backplane
Tyan M1003 LED/Switch/USB Board
Tyan M1013 Adapter Board
Motherboard J46 to Service Processor Cable 422745400008
Motherboard J45 to Adapter Board Cable 422750300006
Motherboard J45 Pins 16/18 to Interlock Switch and Cable
Motherboard J34 to LED/Switch/USB Board Cable 422750300008
SATA Cable 422741900008
CPU Fan/Fan3 Cable 422750300009
Fan1/Fan2 Cable 4227470900004
Rear Locate LED Cable 422750300005
Adapter Board to SATA Backplane Cable 42275030004
Five Fan Kit 1
Fan
512MB DDR400/PC3200 Unbuffered DIMM
1GB DDR400/PC3200 Unbuffered DIMM
ST5800 Rackmount Kit
F540-6905 [F]
380-1380
24-Port Gigabit Ethernet Switch Assembly/FRU
24-Port Gigabit Ethernet Switch
F541-1469 [F]
390-0247
390-0383
541-1495
500GB SATA Disk Drive Assembly/FRU
500GB SATA Disk Drive, Hitachi
500GB SATA Disk Drive, Hitachi
Drive Mounting Bracket
594-3590
540-6798
Sun Rack 1000-38
SR1000-38, 16A/20A PDS, Alloy Doors 1 2
F602-3398 [F]
602-3364
370-7944
370-7940 [F]
310-0098 [F]
371-1599 [F]
375-3427 [F]
371-1600 [F]
540-6644 [F]
540-7054 [F]
Service Processor Assembly/FRU 7
Sun Fire X2100 Base Assembly
1GB DDR400/PC3200 Unbuffered ECC DIMM 3
2.2GHz Opteron 148 Socket 939 (E4 Stepping)
CPU Heatsink
8x DVD-ROM / 24x CD-ROM
System Board
Service Processor
80GB 7200 RPM SATA Disk Drive Assembly
80GB 7200 RPM SATA Disk Drive Assembly
F594-4828
602-3508
371-1998
371-2486 [F]
310-0107 [F]
371-2283 [F]
375-3460 [F]
540-6485 [F]
Service Processor Assembly/FRU 6 7
Sun Fire X2100 M2 ATO Base Assembly
512MB Unregistered ECC DDR2-667/PC5300 DIMM 4
1.8GHz Dual Core Opteron 1210 5
CPU Heatsink
8x DVD-ROM / 24x CD-ROM
System Board
250GB 7200 RPM SATA Disk Drive Assembly
370-7669 [F] Sun Fire X2100 Rackmount Kit
F530-3633 [F]
530-3879
F530-3771 [F]
F530-3794 [F]
530-3880
RJ45 to RJ45 CAT5E Ethernet Cable, 2M
RJ45 to RJ45 CAT5E Ethernet Cable, 2M (replaced 530-3633)
RJ45 to RJ45 CAT5E Ethernet Cable, 1M
RJ45 to RJ45 CAT5E Ethernet Cable, 6M
RJ45 to RJ45 CAT5E Ethernet Cable, 6M (replaced 530-3794)
541-1747
341-2835
341-2836
Switch Mounting Rail
Mounting Rail
Mounting Ear
541-1748
130-5849
341-2837
4-Port Patch Panel
RJ45 to RJ45 Panel Mount Connector
Patch Panel
1 Inactivated as a FRU in March 2007. (WO_35017)
2 The SR1000-38 Power Distribution System includes the parts in Option 5142A-2.
Option 5142A-2 requires AC Power Cord Option 5145, 5146, 5147, or 5148.
3 The Sun Fire X2100 is configured with two 1GB DIMMs.
4 The Sun Fire X2100 M2 is configured with three 512MB DIMMs.
5 The ST5800 Sun Fire X2100 M2 was not built with Opteron 1210 371-1971-01.
6 Configurations using 594-4828 were released in July 2007. (WO_36989)
7 FRUs 594-4828 and 602-3398 were inactivated in October 2007. (WO_37608)

Notes

  1. All Service Processor parts are FRUs.
  2. The StorageTek 5800 does not have a CRU service strategy.

References

  1. StorageTek 5800 Product Documentation

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback