StorageTek 5800
375-3427 |
602-3398 |
Tyan Tomcat K8E S2865 |
Service Processor Assy/FRU
|
Connectors
LOCATION |
DESCRIPTION |
J17 J28 |
Front Panel LAN1 Link and Activity LED
Front Panel LAN2 Link and Activity LED |
J19 J23 |
Front Panel LAN1 Speed LED
Front Panel LAN2 Speed LED |
J30 J31 |
SATA1 to Backplane
SATA2 to Backplane |
J34 J35 |
USB3 to Front I/O Board
USB4 not stuffed |
J37 J38 |
SATA3 not used
SATA4 not used |
J40 |
COM2 Serial Port not used |
J45 |
LED/Power Control Header to Backplane |
J46 |
SMDC to Backplane to Service Processor |
Jumper Settings
LOCATION |
PINS |
SETTING |
DESCRIPTION |
JP1 |
1-2 |
In |
LAN2 Enable (default) |
JP2 |
1-2 2-3 |
In In |
Normal CMOS (default)
Clear CMOS (temporary setting only) |
JP3 |
1-2 2-3 |
In In |
Select 3.3V PCI Slot (default)
Select 5.0V PCI Slot |
StorageTek 5800 Codename: Honeycomb 1.1 |
StorageTek 5800 Notes
- Two 1GB DIMMs are installed in slots DIMM 1 and DIMM 2.
- No memory is installed in slots DIMM 3 and DIMM 4.
- Service Processor FRU 602-2298 was discontinued in October 2007.
(WO_37608)
References
-
Sun StorageTek 5800 System Administration Guide, 819-3810.
-
Sun StorageTek 5800 System Release Notes, 819-3813.
-
Sun StorageTek 5800 System Release Notes, 819-7553.
StorageTek 5800
380-1384 |
Node Chassis Assy/FRU
Tyan Tomcat K8E S2865
|
Connectors
LOCATION |
DESCRIPTION |
J17 J28 |
Front Panel LAN1 Link and Activity LED
Front Panel LAN2 Link and Activity LED |
J19 J23 |
Front Panel LAN1 Speed LED
Front Panel LAN2 Speed LED |
J30 |
SATA1 to Backplane J5 |
J31 |
SATA2 to Backplane J3 |
J37 |
SATA3 to Backplane J2 |
J38 |
SATA4 to Backplane J1 |
J34 |
USB3 to LED/Switch/USB Board |
J40 |
COM2 Serial Port not used |
J45 |
Pins 16/18 to Top Cover Interlock Switch |
J45 |
LED/Power Control Header to M1013 Adapter Board |
J46 |
SMDC to M3290 Service Processor |
Jumper Settings
LOCATION |
PINS |
SETTING |
DESCRIPTION |
JP1 |
1-2 |
In |
LAN2 Enable (default) |
JP2 |
1-2 2-3 |
In In |
Normal CMOS (default)
Clear CMOS (temporary setting only) |
JP3 |
1-2 2-3 |
In In |
Select 3.3V PCI Slot (default)
Select 5.0V PCI Slot |
StorageTek 5800 Codename: Honeycomb 1.1 |
StorageTek 5800 Notes
- The StorageTek 5800 Node uses X2100 System Board 375-3342 with different BIOS.
- The programmed StorageTek 5800 Node System Board has no Sun part number.
- The maximum memory configuration of the StorageTek 5800 Node is 3GB.
- Two 1GB DIMMs are installed in slots DIMM 1 and DIMM 2.
- Two 512MB DIMMs are installed in slots DIMM 3 and DIMM 4.
References
-
Sun StorageTek 5800 System Administration Guide, 819-3810.
-
Sun StorageTek 5800 System Release Notes, 819-3813.
-
Sun StorageTek 5800 System Release Notes, 819-7553.
StorageTek 5800
375-3460 |
594-4828 |
P/N DA0S40MB6D3 MAC Address 001636xxxxxx |
Service Processor Assembly/FRU |
Jumper Settings
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J4 |
1-2 1-2 |
Out In |
Normal AST2000 BMC (default)
Disable/Flash AST2000 BMC |
J7 |
1-2 2-3 |
In In |
Clear CMOS (temporary setting only)
Normal CMOS (default) |
StorageTek 5800 Codename: Honeycomb 1.1 |
Notes
- The memory configuration of the Service Processor is three 512MB DIMMs.
- Install memory beginning at DIMM 0 and ending at DIMM 3.
- System board removal requires a #2 Phillips Screwdriver and an 8mm nutdriver.
- The CPU speed and CPU part number is labeled on the blower air duct.
- Service Processor FRU 594-4828 was discontinued in October 2007.
(WO_37608)
References
-
Sun StorageTek 5800 System Administration Guide, 819-3810.
-
Sun StorageTek 5800 System Release Notes, 819-3813.
-
Sun StorageTek 5800 System Release Notes, 819-7553.
|