Unit |
Disk Configuration |
Sun StorageTek 5320 NAS Appliance (Internal) |
No disks installed within this unit. |
Sun StorageTek 5320 RAID Expansion Unit (External) |
Up to sixteen disk drives as follows:
|
Sun StorageTek 5320 Expansion Unit (External) |
Up to sixteen disk drives as follows:
|
|
Unit |
Total Storage Capacity Per Unit |
Sun StorageTek 5320 NAS Appliance (Internal) |
No disks installed within this unit. |
Sun StorageTek 5320 RAID Expansion Unit (External) |
4.800TB (16 × 300GB)
8.000TB (16 × 500GB)
|
Sun StorageTek 5320 Expansion Unit (External) |
4.800TB (16 × 300GB)
8.000TB (16 × 500GB)
|
Mass Storage |
Is as follows:
- Maximum StorageTek 5320 RAID Expansion Units (EUs): 4
- Maximum StorageTek 5320 Expansion Units:
- 24 EUs (maximum)
- 6 attached to each RAID EU
|
Note 1: Maximum capacity depends on the number of external arrays
you attach to the 5320 NAS Appliance.
Note 2: A Sun StorageTek 5320 NAS Appliance, with a Sun StorageTek 5320 RAID Expansion Unit, and a Sun
StorageTek 5320 Expansion Unit can provide up to:
- 9.600 TB of storage using the 300GB disks (32 × 300GB)
- 16.000 TB of storage using the 500GB disks (32 × 500GB)
|
Processor |
Number |
1 |
Architecture |
2.6GHz CPU, AMD Opteron 252, Single Core |
Cache memory |
1-MB Level 2 cache |
|
PC3200 DDR400 ECC registered DIMM, system supports
4 × 1 GB DIMMs |
Standard
Interfaces |
Network |
Four 10/100/1000BaseT Ethernet ports |
SCSI |
Optional: One Ultra 320 SCSI multimode (SE/LVD) |
USB |
Two USB 1.1 ports |
Expansion Bus |
Five internal PCI-X 64-bit/100 MHz |
Fibre Channel (FC) |
1 or 2 dual-port 2-Gb FC HBAs |
Power
Supplies |
Sun StorageTek 5320 NAS Appliance |
Equipped with two 550W power supplies
Note: Second power supply is for redundancy.
|
Sun StorageTek 5320 RAID Expansion Unit |
Equipped with two 400W power supplies
Note: Second power supply is for redundancy.
|
Sun StorageTek 5320 Expansion Unit |
Equipped with two 400W power supplies
Note: Second power supply is for redundancy.
|
|
AC Power |
- RAID Expansion Unit:
- 2.9 amps maximum operating @ 100VAC, 50/60Hz
- 1.5 amps maximum operating @ 240VAC, 50/60Hz
- Expansion Unit:
- 5.8 amps maximum operating @ 115VAC, 47-63Hz
- 2.9 amps maximum operating @ 230VAC, 47-63Hz
|
Heat Output
|
- NAS Appliance: n/a
- RAID Expansion Unit: 1331 BTU/hr
- Expansion Unit: 1331 BTU/hr
|
Operating Temperature |
- NAS Appliance:
10° C to 35° C (50° F to 95° F)
- RAID Expansion Unit:
10° C to 35° C (50° F to 95° F)
- Expansion Unit:
10° C to 35° C (50° F to 95° F)
|
Nonoperating Temperature |
- NAS Appliance:
-40° C to 65° C (-40° F to 149° F)
- RAID Expansion Unit:
-10° C to 45° C (14° F to 113° F)
- Expansion Unit:
-10° C to 45° C (14° F to 113° F)
|
Operating Humidity |
- NAS Appliance: 10% to 90% (noncondensing)
- RAID Expansion Unit: 20% to 80% (noncondensing)
- Expansion Unit: 20% to 80% (noncondensing)
|
Nonoperating Humidity |
- NAS Appliance: Up to 93% (noncondensing)
- RAID Expansion Unit: 10% to 90% (noncondensing)
- Expansion Unit: 10% to 90% (noncondensing)
|
Operating Altitude |
- NAS Appliance (non-rack): Up to 3048 m (10000 ft)1
- RAID Expansion Unit: 30.5 m (100 ft) below sea level to 12000 m (40000 ft)
- Expansion Unit: 30.5 m (100 ft) below sea level to 12000 m (40000 ft)
1Maximum ambient temperature is derated by 1 degree C per 300 m (984.252 ft)
above 900m (2952.76 ft).
|
Nonoperating Altitude |
Up to 12000 m (39370.1 ft)
|
|
Height |
- NAS Appliance: 8.76 cm (3.45 in)
- RAID Expansion Unit: 12.95 cm (5.1 in)
- Expansion Unit: 12.95 cm (5.1 in)
|
Width |
- NAS Appliance: 44.5 cm (17.52 in)
- RAID Expansion Unit: 48.26 cm (19 in)
- Expansion Unit: 48.26 cm (19 in)
|
Depth |
- NAS Appliance: 64.0 cm (25.2 in)
- RAID Expansion Unit: 57.15 cm (22.5 in)
- Expansion Unit: 57.15 cm (22.5 in)
|
Maximum Weight |
- NAS Appliance: 23.6 kg (52.1 lb)
- RAID Expansion Unit: 40 kg (88 lb)
- Expansion Unit: 40 kg (88 lb)
|
|
Meets or exceeds the following requirements:
|
RoHS Compliance Level |
RoHS:YL |
Safety |
- NAS Appliance: IEC 60950, UL/CSA 60950, EN 60950, CB Report with all national differences
- RAID Expansion Unit: IEC 60950, UL 60950, EN 60950, UL 1950, FCC Part 15 (47CRF15B),
CISPR 22 (EN55022 - RF Radiated and Conducted Emissions), IEC 61000-3-2, IEC 61000-3-3
- Expansion Unit: IEC 60950, UL 60950, EN 60950, UL 1950, FCC Part 15 (47CRF15B),
CISPR 22 (EN55022 - RF Radiated and Conducted Emissions), IEC 61000-3-2, IEC 61000-3-3
|
RFI/EMI |
- NAS Appliance: Class A, FCC CFR47 Part 15, ICES-003, EN55022, EN 300 386 v1.3.2
- RAID Expansion Unit: n/a
- Expansion Unit: n/a
|
Immunity |
- NAS Appliance: EN55024, EN 300 386 v1.3.2
- RAID Expansion Unit: CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
- Expansion Unit: CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
|