73.4GB 10K RPM
  • Fujitsu MAW3073FC, 73.4GB - 10000 RPM FC Disk Drive
  • Hitachi HUS1073FA, 73.4GB - 10000 RPM FC Disk Drive
  • Seagate ST373207FC, 73.4GB - 10000 RPM FC Disk Drive
73.4GB 15K RPM
  • Seagate ST373454FC, 73.4GB - 15000 RPM FC Disk Drive
  • Hitachi, 73.4GB - 15000 RPM FC Disk Drive
146.8GB 10K RPM
  • Fujitsu MAW3147FC, 146.8GB - 10000 RPM FC Disk Drive
  • Hitachi HUS1014FA, 146.8GB - 10000 RPM FC Disk Drive
  • Seagate ST3146707FC, 146.8GB - 10000 RPM FC Disk Drive
146.8GB 15K RPM
  • Seagate ST3146854FC, 146.8GB - 15000 RPM FC Disk Drive
  • Fujitsu, 146.8GB - 15000 RPM FC Disk Drive
300GB 10K RPM
  • Fujitsu MAW3300FC, 300GB - 10000 RPM FC Disk Drive
  • Seagate ST3300007FC, 300GB - 10000 RPM FC Disk Drive
Note 1: All RAID configurations ship pre-configured with RAID level zero (RAID 0).
Note 2: Supported RAID levels include 0, 1, 0+1, 1+0, 3, 5, 3+0, and 5+0.
Up to 12 Disk drives per array
73.4GB Disk drives 12 x 73.4 = 880.8GB
146.8GB Disk drives 12 x 146.8 = 1.762TB
300GB Disk drives 12 x 300 = 3.6TB
Power Requirement AC: 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
DC: -36 to -75 VDC
Input Voltage AC: 100 to 240 VAC, single phase
DC: -48 to -60 VDC, 18A
Current Per Input AC: 100 to 240 VAC, 50 to 60 Hz, 5.0-7.1 A
DC: -48 or -60 VDC, 18A
Heat Output 785 BTU/hr (fully populated array, max)
Altitude Operating: -30 m to 3,048 m(-100 to 10000 feet)
Non-operating: -30 m to 12192 m(-100 to 40000 feet)
Temperature Operating: 5° C to 40° C (41° F to 104° F)
Non-operating: -40° C to 65° C (-40° F to 149° F)
Humidity Operating: 10% to 90% relative to 27° C max. wet bulb, noncondensing
Non-operating: 93% relative to 38° C max. wet bulb, noncondensing
Shock Operating: 5.0 G, 11-ms, half-sine
Non-operating: 15.0 G, 11-ms, half-sine
Vibration Operating: 0.2 G, 5-500 Hz, swept-sine
Non-operating: 1.0 G, 5-500 Hz, swept-sine
Height Desktop: 9.25 cm (3.64 in)
Rackmount: 8.89 cm (3.5 in)
Width Desktop: 48.26 cm (19 in)
Rackmount: 44.7 cm (17.6 in)
Depth Main Chassis with bezel: 48.36 cm (19.04 in)
Chassis with Power/Fan Modules and bezel: 53.44 cm (21.04 in)
Chassis with Power/Fan Modules, Handles and bezel: 55.98 cm (22.04 in)
Weight (with 12 disks) Desktop: 31.43 kg (69.3 lbs)
Rackmount: 28.71 kg (63.3 lbs)
RoHS Compliance Level RoHS:YL
Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003
Emission VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark
Harmonics IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001
Immunity CSIPR 24 EN 55024
Other NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386
Front 37 cm (15 in) service clearance, 15 cm (6 in) cooling clearance
Rear 37 cm (15 in) service clearance, 15 cm (6 in) cooling clearance
Airflow for cooling is from front to rear
Rack mountable in 19" wide rack

 


  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.