Sun StorEdge[tm] 3510 FC Array, RoHS:YL: Hardware Specifications
|
|
73.4GB 10K RPM |
- Fujitsu MAW3073FC, 73.4GB - 10000 RPM FC Disk Drive
- Hitachi HUS1073FA, 73.4GB - 10000 RPM FC Disk Drive
- Seagate ST373207FC, 73.4GB - 10000 RPM FC Disk Drive
|
73.4GB 15K RPM |
- Seagate ST373454FC, 73.4GB - 15000 RPM FC Disk Drive
- Hitachi, 73.4GB - 15000 RPM FC Disk Drive
|
146.8GB 10K RPM |
- Fujitsu MAW3147FC, 146.8GB - 10000 RPM FC Disk Drive
- Hitachi HUS1014FA, 146.8GB - 10000 RPM FC Disk Drive
- Seagate ST3146707FC, 146.8GB - 10000 RPM FC Disk Drive
|
146.8GB 15K RPM |
- Seagate ST3146854FC, 146.8GB - 15000 RPM FC Disk Drive
- Fujitsu, 146.8GB - 15000 RPM FC Disk Drive
|
300GB 10K RPM |
- Fujitsu MAW3300FC, 300GB - 10000 RPM FC Disk Drive
- Seagate ST3300007FC, 300GB - 10000 RPM FC Disk Drive
|
Note 1: All RAID configurations ship pre-configured with RAID level zero (RAID 0).
Note 2: Supported RAID levels include 0, 1, 0+1, 1+0, 3, 5, 3+0, and 5+0.
|
|
Up to 12 Disk drives per array |
73.4GB Disk drives |
12 x 73.4 = 880.8GB |
146.8GB Disk drives |
12 x 146.8 = 1.762TB |
300GB Disk drives |
12 x 300 = 3.6TB |
|
Power Requirement |
AC: 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
DC: -36 to -75 VDC |
Input Voltage |
AC: 100 to 240 VAC, single phase
DC: -48 to -60 VDC, 18A |
Current Per Input |
AC: 100 to 240 VAC, 50 to 60 Hz, 5.0-7.1 A
DC: -48 or -60 VDC, 18A |
Heat Output |
785 BTU/hr (fully populated array, max) |
Altitude |
Operating: -30 m to 3,048 m(-100 to 10000 feet)
Non-operating: -30 m to 12192 m(-100 to 40000 feet) |
Temperature |
Operating: 5° C to 40° C (41° F to 104° F)
Non-operating: -40° C to 65° C (-40° F to 149° F) |
Humidity |
Operating: 10% to 90% relative to 27° C max.
wet bulb, noncondensing
Non-operating: 93% relative to 38° C max. wet bulb, noncondensing |
Shock |
Operating: 5.0 G, 11-ms, half-sine
Non-operating: 15.0 G, 11-ms, half-sine |
Vibration |
Operating: 0.2 G, 5-500 Hz, swept-sine
Non-operating: 1.0 G, 5-500 Hz, swept-sine |
|
Height |
Desktop: 9.25 cm (3.64 in)
Rackmount: 8.89 cm (3.5 in) |
Width |
Desktop: 48.26 cm (19 in)
Rackmount: 44.7 cm (17.6 in) |
Depth |
Main Chassis with bezel: 48.36 cm (19.04 in)
Chassis with Power/Fan Modules and bezel: 53.44 cm (21.04 in)
Chassis with Power/Fan Modules, Handles and bezel: 55.98 cm (22.04 in) |
Weight (with 12 disks) |
Desktop: 31.43 kg (69.3 lbs)
Rackmount: 28.71 kg (63.3 lbs) |
|
RoHS Compliance Level |
RoHS:YL |
Safety |
UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN
60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15
Class B, CISPR 22 55022:1998 Class B, ICES-003 |
Emission |
VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class
B, S Mark |
Harmonics |
IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001 |
Immunity |
CSIPR 24 EN 55024 |
Other |
NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F,
ETSI EN 300 386 |
|
Front |
37 cm (15 in) service clearance, 15 cm (6 in) cooling
clearance |
Rear |
37 cm (15 in) service clearance, 15 cm (6 in) cooling
clearance |
Airflow for cooling is from front to rear |
|
Rack mountable in 19" wide rack |
|
|