Sun StorEdge[tm] 3120 SCSI Array, RoHS:YL: Hardware Specifications
|
|
73.4GB 10K RPM |
- Fujitsu MAW3073NC, 73.4GB - 10000 RPM, 1 inch, Ultra 320 Disk Drive
- Hitachi HUS103073A, 73.4GB - 10000 RPM, 1 inch, Ultra 320 Disk Drive
- Seagate ST373207LC, 73.4GB - 10000 RPM, 1 inch, Ultra 320 Disk Drive
|
73.4GB 15K RPM |
- Seagate ST373454LC, 73.4GB - 15000 RPM, 1 inch, Ultra 320 Disk Drive
- Hitachi HUS151473VL3800, 73.4GB - 15000 RPM, 1 inch, Ultra 320 Disk Drive
- Fujitsu MAX3073NC, 73.4GB - 15000 RPM, 1 inch, Ultra 320 Disk Drive
|
146.8GB 10K RPM |
- Fujitsu MAW3147NC, 146.8GB - 10000 RPM, 1 inch, Ultra 320 Disk Drive
- Hitachi HUS103014FL3800, 146.8GB - 10000 RPM, 1 inch, Ultra 320 Disk Drive
- Seagate ST3146707LC, 146.8GB - 10000 RPM, 1 inch, Ultra 320 Disk Drive
|
146.8GB 15K RPM |
- Seagate ST3146854LC, 146.8GB - 15000 RPM, 1 inch, Ultra 320 Disk Drive
- Hitachi HUS151414VL3800, 146.8GB - 15000 RPM, 1 inch, Ultra 320 Disk Drive
- Fujitsu MAX3147NC, 146.8GB - 15000 RPM, 1 inch, Ultra 320 Disk Drive
|
300GB 10K RPM |
- Seagate ST3300007LC, 300GB - 10000 RPM, 1 inch, Ultra 320 Disk Drive)
|
|
Up to 4 Disk drives per array |
73.4GB Disk drives |
4 x 73.4 = 293.6GB |
146.8GB Disk drives |
4 x 146.8 = 587.2GB |
300GB Disk drives |
4 x 300 = 1.2TB |
|
Power Requirement |
AC: 90 to 264 VAC, 47 to 63 Hz
DC: -36 to -72 VDC |
Input Voltage |
AC: 100 to 240 VAC, single phase
DC: -48 or -60 VDC, 18A |
Current Per Input |
AC: 100 to 240 VAC, 50-60 Hz, 5.0-7.1A
DC: -48 or -60 VDC, 18A |
Maximum Inrush Current |
100 VAC: 50A peak
240 VAC: 100A peak |
AC Power Consumption |
Idle: 70 W @ 110 V AC; 70 W @ 230 V AC Operating: 75 W @ 110 V AC; 75 W @ 230 V AC
Spin up: 180 W @ 110 V AC; 180 W @ 230 V AC |
Power Supply Output Voltages |
+5VDC and +12VDC |
Heat Output |
170 BTU/hr |
Altitude |
Operating: -30 to 3048 Meters (-100 to 10000
ft)
Non-operating: -30 to 12192 Meters (-100 to 40000 ft) |
Temperature |
Operating: 5° C to 40° C (41° F to 104° F)
Non-operating: -40° C to 65° C (-40° F to 149° F) |
Humidity |
Operating: 10% to 90% @ 27° C max wet bulb (80.6°
F), noncondensing
Non-operating: 0% to 93% @ 38° C (100.4° F), noncondensing |
Shock |
Operating: 5.0 g's, 11ms, half-sine
Non-operating: 15 g's, 11ms, half sine (x, y and z axis) |
Vibration |
Operating: 0.20 G, 5 to 500 Hz, swept-sine
Non-operating: 1.0 G, 5 to 500 Hz, swept-sine |
|
Height |
4.4 cm (1.75 in) |
Width |
48.2 cm (19 in) |
Depth |
53.3 cm (21 in) |
Weight |
fully populated: 13.6 kg (30 lb)
with packaging: 18.4 kg (40.6 lb) |
|
RoHS Compliance Level |
RoHS:YL |
Safety |
UUL Listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN
60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S Mark; GS Mark |
Emission |
FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003,
VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark |
Harmonics |
IEC 61000-3-2:2000, IEC 61000-3-3:1995/A1:2001 |
Immunity |
CISPR 24 EN 55024 |
Other |
NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F,
ETSI EN 300 386 |
|
Front |
38 cm (15 in) for service access
15 cm (6 in) for cooling |
Rear |
38 cm (15 in) for service access
15 cm (6 in) for cooling |
|
Rack mountable in 19" wide rack, |
|
|