Netra 440
N42
501-6344 |
501-6910 |
540-5919-04/05 |
540-5919-06 |
Motherboard 270-6344-05/06/07 June 2003 |
Motherboard 270-6344-07 September 2004 |
Motherboard FRU 501-6344 March 2004 |
Motherboard FRU 501-6910 September 2004 |
501-7343 |
540-6710 |
Motherboard 270-6344-07 May 2006 L |
Motherboard FRU 501-7343 May 2006 L |
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J4202 |
1-2 2-3 |
In In |
Normal Real Time Clock (default)
Clear Real Time Clock CMOS |
J4204 |
1-3 |
Out |
1-2=XIR 2-3=POR (default) |
J4205 |
1-3 2-3 |
Out In |
Flash Write Protected *
Flash Write Enabled (default) * |
J4206 |
1-2 2-3 |
In In |
Select ROMBO
Select Flash (default) |
J4207 |
2-3 1-2 |
In In |
Normal Flash (default)
Flash Recovery |
* Jumpering 1-2 has no effect because Pin-1 not connected.
The Flash PROM is write protected when:
J4205 Pins 2-3 are Not jumpered
or the Keyswitch is in the
Locked position
The Flash PROM is write enabled when:
J4205 Pins 2-3 are jumpered
and the Keyswitch is in the
Normal or Diagnostic position
and the PROM_SB_WE_N
signal is software enabled
|
Netra 440 Codename: Chalupa 19 |
Notes
- The minimum operating system is Solaris 8 7/03 or Solaris 9 12/03.
- Motherboard 501-6910 replaced 501-6344 in September 2004.
(WO_29866)
- Motherboard 501-6910 requires ALOM >=1.5.
See FCO
A0245-1.
- See FAB article
1000080.1
for information on possible need for ALOM >=1.6.2.
Memory Notes
- Bank, Rank, DIMM, and XOR Interleaving is supported.
- UltraSPARC IIIi supports single bank and dual bank DDR DIMMs.
- Two DIMMs of the same bank size (single or dual) and memory size form a
bank.
- The minimum requirement is two DIMMs in any Bank (B0/D0/D1 or B1/D0/D1).
- Memory error reporting identifies a failing Bank, not a single failing DIMM.
Motherboard Notes
- The pre-RoHS Motherboard FRU includes Tray 340-7996, Motherboard 501-6344,
Rear LED Extension Cable 530-3309, and CPU/Memory Shroud 540-5285.
- The RoHS Motherboard FRU includes Tray 340-7996, Motherboard 501-7343,
Rear LED Extension Cable 530-3309, and CPU/Memory Shroud 541-1436.
- The CPU/Memory Shroud holds Tomatillo heatsinks at U1501 and U2601 in place.
- Master Tomatillo interfaces include the ALOM Slot, Ethernet 1, Flash PROM,
I2C, ATA-100, PCI Slots 0, 1, and 3, SCSI, Serial B,
Serial PROM, Smart Card Reader, TOD, and USB 0-3.
- Slave Tomatillo interfaces include Ethernet 0, and PCI Slots 2, 4, and 5.
References
-
Netra 440 Server Product Overview, 817-3881.
-
Netra 440 Server Installation Guide, 817-3882.
-
Netra 440 Server Service Manual, 817-3883.
-
Netra 440 Server System Administration Guide, 817-3884.
-
Netra 440 Server Release Notes, 817-3885.
-
Netra 440 Server Diagnostics and Troubleshooting Guide, 817-3886.
|