This section provides the most common repair procedures for the 
  Ultra 80 workstation. The written procedures below are links to the 
Sun 
  Ultra 80 Service Manual (805-6618). 
   
    | Component | 
     
       Remove 
     | 
     
       Install 
     | 
    Tips | 
  
   
    | Audio Module Assembly | 
     
      
     | 
     
      
     | 
      | 
  
   
    | CD-ROM Drive | 
     
      
     | 
     
      
     | 
      | 
  
   
    | CPU Module | 
     
      
     | 
     
      
     | 
     
      
        -  
          
Tuning the ecache_scan_rate parameter of the Solaris 
            cache scrubber provides improved Ecache parity error protection on 
            non-mirrored SRAM UltraSPARC II-based systems (FIN  I0755-1).  
         
        -  
          
OS mapping versus physical location of CPU modules 
            for E420R, E450, U80 and Netra t1400/t1405 systems may lead to incorrect 
            module replacement (FIN  I0749-1).  
         
        -  
          
The current diagnostic procedure to 
            identify the faulty CPU module from CPU Ecache parity errors is flawed 
            (FIN I0570-3). 
         
       
     | 
  
   
    |  
        Disk Drive 
     | 
     
      
     | 
     
      
     | 
     
      
        -  
          
18.2GB and 36GB IBM disk drives may be susceptible 
            to early life failures problem (FIN  I0724-2).  
         
        - 18GB and 36GB IBM disk drives experiencing high failure rate in high 
          humidity and high temperature environments (FCO A0182-1).
 
       
     | 
  
   
    | Floppy Drive | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Memory  | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Memory Riser Assembly | 
     
      
     | 
     
      
     | 
     
      
        - See 
 Memory Riser Assembly Damage 
          Caution. 
        - System initialization failures are sometimes being diagnosed incorrectly 
          due to an improperly installed Memory Riser card (FIN I0607-1).
 
        - Failure to properly assemble the Memory Riser to the correct torque 
          setting can cause intermittent memory related system problems (FIN I0537-2).
 
       
     | 
  
   
    | NVRAM/TOD Module | 
     
      
     | 
     
      
     | 
      | 
  
   
    | PCI Card | 
     
      
     | 
     
      
     | 
     
      
        - Ultra 80 system board based systems may panic at boot time with certain 
          PCI Bus configurations (FIN I0665-1).
 
        -  
          
 
            SunPCi II and SunPCi IIpro cards may not respond 
              after rapid/successive power cycling (FCO  A0186-1).  
           
         
        - A host system using the 375-0040-01 or -02 FC100/P FC-AL PCI card 
          to attach to FC-AL storage (StorEdge A5x00 and A3500) may experience 
          loop errors, which may affect data access to that storage (FCO A0164-1).
 
        - Systems based on the PSYCHO chipset panic with a PCI bus error (SRDB 
          40602). 
        
 
       
     | 
  
   
    | Peripheral Assembly (contains CD-ROM, Tape Drive, and Floppy Drive) | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Power Supply Assembly | 
     
      
     | 
     
      
     | 
      | 
  
   
    | System Board | 
     
      
     | 
     
      
     | 
     
        
       
     | 
  
   
    | Tape Drive | 
     
      
     | 
     
      
     | 
      | 
  
   
    |  
       UPA Graphics Card 
     | 
     
      
     | 
     
      
     | 
     
      
        -  
          
SunBlade 1000/2000 and Ultra 60/80 systems may exhibit 
            a blank screen upon boot up with an XVR-1000 Graphics Accelerator 
            installed (FCO  A0200-1).  
         
       
     | 
  
   
    |  
       UPA Graphics Card (Elite 3D) 
     | 
     
      
     | 
     
      
     | 
     
      
     |