       FCO 
     | 
     
       Impl. 
     | 
    Components 
      Affected | 
    Description | 
  
  
    | A0202-1 | 
    
       U 
     | 
    20 GB Seagate ST320414A (370-4327-01) | 
    Mirrored 20GB disk drives on Ultra 10 
      and Sun Blade 100 systems may be exposed to a drive compatibility issue 
      when replacing a failed drive. | 
  
   
    | A0197-1 | 
     
       U 
     | 
    Ultra 10 (serial number xx101xxxxx to 
      xx214xxxxx) | 
    Ultra 10 Systems within an affected serial 
      number range may not pass EMI. | 
  
   
    | A0186-1 | 
     
       U 
     | 
    SunPCi II (375-0131-04) and SunPCi IIpro 
      (375-3051-01) cards | 
    SunPCi II and SunPCi IIpro cards may not 
      respond after rapid/successive power cycling. | 
  
   
    | A0182-1 | 
     
       C 
     | 
    18GB and 36GB IBM disk drives | 
    18GB and 36GB IBM disk drives experiencing 
      high failure rate in high humidity and high temperature environments. | 
  
   
    | A0173-1 | 
     
       U 
     | 
    CPU Module SR 400MHz (501-5741-01), CPU 
      Module SR 360MHz (501-5148-06), CPU Module SR 440MHz (501-5149-08) | 
    Ultra 5 and Ultra 10 systems with Sapphire 
      Red Modules have shown an increase in early life failures. | 
  
   
    | A0152-1 | 
     
       U 
     | 
    4-slot Riser Card (370-3197-02 or below) | 
     
       PCI cards in Ultra 10 not accessible due to mechanical alignment and 
        seating problems with the PCI Riser card. There are no error messages 
        that indicate that the card is not seated correctly. 
      You may be able to determine if the card is not properly installed by 
        looking at the connectors. The card should be parallel and even with the 
        connector, the PCI card should not appear to be at an angle. The root 
        cause has been attributed to the design of the support bracket. 
     | 
  
   
    | A0146-1 | 
     
       U 
     | 
    FFB2+ Vertical/SB (501-4789-05 or below); 
      FFB2+ Vertical/DBZ (501-4788-05 or below)  | 
    Systems with FFB2+ installed may experience 
      right shift of horizontal lines that contain the cursor and/or border line 
      curves toward the mouse pointer when the mouse pointer is placed close to 
      the left border of a cmdtool window. This can be easily seen when you set 
      the FFB resolution to 960x680x112s with cmdtool's foreground color set to 
      black and background to white. | 
  
   
    | A0143-1 | 
     
       M 
     | 
    System Board (375-0066-03) | 
    Reverse capacitor failure in Ultra 5 and 
      Ultra 10 systems. Reverse bias voltage in excess of 20% of manufacturing 
      specification will cause early life failure of the capacitor and, in addition, 
      may cause damage to surrounding PCB or components and/or product functional 
      failure. | 
  
   
    | A0139-1 | 
     
       U 
     | 
     
       PGX PCI-based 8-bit Frame Buffer (370-2256-02) 
     | 
     
       Systems with a PGX PCI-based 8-bit Frame Buffer may display a vertical 
        black stripe when running the OpenWindows environment. This occurs only 
        with frame buffers with an Fcode version 1.09 (determined by reading the 
        label on the EPROM located at U4 on the frame buffer: 113-377-1-109). 
     | 
  
   
    | A0137-1 | 
     
       U 
     | 
    300MHz UltraSPARC IIi Module (501-4379/501-5040) 
     | 
    Ultra 10 will hang running SunVTS with 
      either an AFB or FFB2 video card installed. | 
  
   
    | A0128-2 | 
     
       U 
     | 
    System Board (375-0009-05 or below) | 
     
       Ultra5 and Ultra10 systems may experience fuzzy video, slow booting, 
        and serial port hang when using the external clock source as transfer 
        clock in SYNC mode (X.25). 
     |