This section provides the most common repair procedures for the 
  Sun Fire V880. The following links are located in the 
Sun 
  Fire V880 Server Service Manual (806-6597).
   
    | Component | 
     
       Remove 
         
     | 
     
       Install 
     | 
    Tips | 
  
   
    | Cable Connector Locations | 
     
       n/a 
     | 
     
       n/a 
     | 
    
      
        - Diagram showing cable connector locations is on page 221
 
       
     | 
  
   
    | Cable Routing | 
     
       n/a 
     | 
     
       n/a 
     | 
    
      
        - Table showing cable routing information is on page 222. The cabling 
          instructions for the Loop B PCI FC-AL data cable are incorrect in the 
          Sun Fire V880 Service Manual, due to a late change to the labeling scheme 
          on the cable's connectors. The correct cabling information is provided 
          below:
 
           
        
      
      
         
          | Cable Name | 
          Part Number | 
          Cable End | 
          Connect To | 
         
         
          | Loop B PCI FC-AL data cable | 
          530-3056 | 
           
             D 
           | 
          Base backplane at D | 
         
         
          |  
             C 
           | 
          Base backplane at C | 
         
         
          |  
             P3 
           | 
          PCI card at J3 | 
         
         
          |  
             P4 
           | 
          PCI card at J4 | 
         
       
        
       
     | 
  
   
    | CPU Fan Status Assembly | 
     
       61 
     | 
     
       63 
     | 
      | 
  
   
    | CPU Fan Tray | 
     
       50 
     | 
     
       53 
     | 
    
      
        - prtdiag reports fan failures as ENABLED with a speed of 0 
 
          (BugID 4431194). 
 
Please check the current revision of 
          the 
 Sun Fire V880 Server Product Notes 
          for more information.  
       
     | 
  
   
    | CPU/Memory Board | 
     
       32 
     | 
     
       37 
     | 
     
      
        - Issue with diagnosing of "send mondo" panics (FIN I0765-1).
 
        - UltraSPARC III and III+ based platforms could be susceptible to UCC 
          errors that may cause system panics (FIN I0856-1).
 
        - Guidelines for understanding and diagnosing UltraSPARC III Level 2 
          (L2) SRAM Cache Memory Errors (FIN I0887-1).
 
        - The 3.3V DC-DC Converter on Sun Fire V880 CPU/Mem Boards may cause 
          the system to shutdown and start reboot process around the failed CPU/Mem 
          Board (FCO A0188-1).
 
       
     | 
  
   
    | CPU/Memory Board Status Assembly | 
     
       65 
     | 
     
       67 
     | 
      | 
  
   
    | DC-to-DC Converter | 
     
       n/a 
     | 
     
       n/a 
     | 
    
      
        - 816-4517 - This 
          document describes the procedure for replacing the DC-to-DC converter 
          on a 750 MHz CPU/Memory board (part number 501-5818-05) for the Sun 
          Fire V880 server. You must replace the DC-to-DC converter on every -05 
          CPU/Memory board that has not had work order WO_23160 performed on it. 
          This must be done for every -05 CPU/Memory board in a system. A -05 
          CPU/Memory board that already has the replacement DC-to-DC converter 
          on it is identified by the work order label WO_23160 affixed to the 
          front label of the board, as shown in the following illustration. 
 
          Note: You do not have to replace the DC-to-DC converter on the 
          -07 750 MHz CPU/Memory board, part number 501-5818-07. 
       
     | 
  
   
    | Disk Backplane (Base) | 
     
       189 
     | 
     
       191 
     | 
    
      
        - NOTE: When updating the disk backplane firmware using patch 
          111474, the superuser prompt will return after issuing the luxadm command 
          in step 2 of the patch instructions. You must wait at least 15 minutes 
          after the superuser prompt returns before continuing or performing any 
          other operations. This minimum wait time is required for the flash update 
          process to propagate the firmware code to all SSC100 processors in the 
          system.
 
       
     | 
  
   
    | Disk Backplane (Expansion) | 
     
       182 
     | 
     
       185 
     | 
     
      
        - The procedure How to Install the Expansion FC-AL Backplane as documented 
          in the Sun Fire V880 Server Service Manual is incomplete. Please check 
          the current revision of the 
 Sun Fire 
          V880 Server Product Notes for the corrected procedure. 
        - NOTE: When updating the disk backplane firmware using patch 
          111474, the superuser prompt will return after issuing the luxadm command 
          in step 2 of the patch instructions. You must wait at least 15 minutes 
          after the superuser prompt returns before continuing or performing any 
          other operations. This minimum wait time is required for the flash update 
          process to propagate the firmware code to all SSC100 processors in the 
          system.
 
       
     | 
  
   
    | Disk Backplane Firmware Upgrade | 
     
       n/a 
     | 
     
       n/a 
     | 
    
      
        - When updating the disk backplane firmware using patch 
 111474, 
          the superuser prompt will return after issuing the luxadm command in 
          step 2 of the patch instructions. You must wait at least 15 minutes 
          after the superuser prompt returns before continuing or performing any 
          other operations. This minimum wait time is required for the flash update 
          process to propagate the firmware code to all SSC100 processors in the 
          system. 
       
     | 
  
   
    | Disk Cage | 
     
       193 
     | 
     
       199 
     | 
     
      
        - The procedure How to Install the FC-AL Disk Cage as documented in 
          the Sun Fire V880 Server Service Manual is incomplete. The following 
          task should be included as Step 9c: 
 
       
       
        9c. If a Sun StorEdge PCI Dual Fibre Channel Host Adapter card is installed 
          to control Loop B of the FC-AL disk backplane, connect the card s FC-AL 
          data cable to the base backplane at connectors C(J01100) and D(J01101). 
       
     | 
  
   
    | Disk Drive | 
     
       166 
     | 
     
       169 
     | 
     
      
        - Power management issue causes loss of access to internal fiber channel 
          disks on the Sun Blade 1000/2000, Sun Fire V880, V480, and 280R (FIN 
          I0888-1). 
        
 
        - Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible 
          to label corruption (FIN I0816-1).
 
        - Removing and Replacing the Sun Fire 280R (Littleneck), 480R (Cherrystone), 
          or 880R (Daktari) hot-pluggable internal disk drives (SRDB 40517).
 
        - Correcting device paths when replacing fiber boot disks after a ufsrestore 
          (InfoDoc 40133).
 
        - Replace a Sun StorEdge[TM] Volume Manager controled internal drive 
          in a Sun Fire[TM] V880 (InfoDoc 44775)
 
        - All FC-AL disk drives installed in a Sun Fire V880 system must meet 
          the minimum firmware revision levels for Sun Fire V880 systems. Incorrect 
          firmware can cause a variety of system problems that are often difficult 
          to diagnose. To determine a disk drive's firmware revision level, use 
          the inquiry feature of the Solaris format(1M) utility. The following 
          table shows the minimum firmware revision levels for Sun Fire V880 disk 
          drives as of 8/31/01. Please check the current revision of the 
 Sun 
          Fire V880 Server Product Notes for current information. 
           
          
             
              | Sun Part No. | 
              Capacity | 
              Manufacturer | 
              Minimum Firmware Revision Level | 
             
             
              | 540-4525 | 
              Seagate 
                Seagate  | 
              ST336605FC 
                ST336704FC  | 
              0438 
                0726 | 
             
             
              | 540-4905 | 
              Seagate | 
              ST373405FC | 
              0438 | 
             
           
         
        - The procedure How to Install a Disk Drive as documented in the Sun 
          Fire V880 Server Service Manual and the Sun Fire V880 Server Owner s 
          Guide is incomplete. The following task should be included in the procedure 
          after Step 10: 
          
 
            11. If you are installing more than one disk drive as part of a 
              hot-plug procedure, wait for the green light on the drive you just 
              installed to light steadily (not flashing) before installing another 
              drive. 
           
         
        - Removing disk drives during hot-plugging requires devfsadm -C command 
           
            (BugID 4418718) 
           
          Please check the current revision of the 
 Sun Fire V880 Server Product Notes for more information. 
       
     | 
  
   
    | DVD-ROM | 
     
       172 
     | 
     
       176 
     | 
      | 
  
   
    | I/O Board | 
     
       132 
     | 
     
       141 
     | 
      | 
  
   
    | I/O Fan LED Flex Circuit | 
     
       124 
     | 
     
       126 
     | 
      | 
  
   
    | I/O Fan Tray | 
     
       84 
     | 
     
       86 
     | 
    
      
        - prtdiag reports fan failures as ENABLED with a speed of 0 
 
          (BugID 4431194) 
 
. Please check the current revision 
          of the 
 Sun Fire V880 Server Product 
          Notes for more information.  
       
     | 
  
   
    | Memory | 
     
       42 
     | 
     
       46 
     | 
    
      
        - Too many Memory DIMMs are being unnecessarily replaced on UltraSPARC 
          III family of systems utilizing NG-DIMM memory (FIN I0760-1).
 
- DIMM error messages on Sun Fire V880 systems with Solaris 8 
          Updates 5 and 6 make it difficult to identify the failing DIMM. (FIN I0839-1).
 
       
     | 
  
   
    | Motherboard | 
     
       73 
     | 
     
       78 
     | 
      | 
  
   
    | Motherboard Fan Status Flex Circuit | 
     
       69 
     | 
     
       71 
     | 
      | 
  
   
    | Motherboard Fan Tray | 
     
       56 
     | 
     
       59 
     | 
     
      
        - The procedure How to Remove a Motherboard Fan Tray in the Sun Fire 
          V880 Server Service Manual is incorrect. On systems configured with 
          the redundant cooling option, removing motherboard fan tray 5 (the primary 
          motherboard fan tray) requires that you disconnect the cable for motherboard 
          fan tray 6. Please see the 
 Sun Fire 
          V880 Server Product Notes for the corrected removal and installation 
          procedure. 
        - prtdiag reports fan failures as ENABLED with a speed of 0 
 
          (BugID 4431194) 
 
. Please check the current revision 
          of the 
 Sun Fire V880 Server Product 
          Notes for more information.  
       
       | 
  
   
    | PCI Card | 
     
       88 
     | 
     
       93 
     | 
    
      
        - UltraSPARC III systems may panic due to a conflict between the Schizo 
          2.4 ASIC and the GigaSwift Ethernet PCI Card (FIN I0874-1).
 
       
     | 
  
   
    | PCI Dual Fibre Channel Host Adapter Card | 
     
       106 
     | 
     
       111 
     | 
    
      
        - The cabling instructions for the Loop B PCI FC-AL data cable are incorrect 
          in the Sun Fire V880 Service Manual, due to a late change to the labeling 
          scheme on the cable's connectors. The correct cabling information is 
          provided below:
 
           
        
      
         
          | Cable Name | 
          Part Number | 
          Cable End | 
          Connect To | 
         
         
          | Loop B PCI FC-AL data cable | 
          530-3056 | 
           
             D 
           | 
          Base backplane at D | 
         
         
          |  
             C 
           | 
          Base backplane at C | 
         
         
          |  
             P3 
           | 
          PCI card at J3 | 
         
         
          |  
             P4 
           | 
          PCI card at J4 | 
         
       
        
       
     | 
  
   
    | PCI External LED Flex Circuit | 
     
       120 
     | 
     
       122 
     | 
      | 
  
   
    | PCI Internal LED Flex Circuit | 
     
       116 
     | 
     
       118 
     | 
      | 
  
   
    | Power Distribution Board | 
     
       208 
     | 
     
       214 
     | 
      | 
  
   
    | Power Supply | 
     
       150 
     | 
     
       155 
     | 
     
      
        - Intermittent picld errors during power supply hot-plug 
 
          (BugID 4431165) 
 
. Please check the current revision 
          of the 
 Sun Fire V880 Server Product 
          Notes for more information.  
        - Hot-plug function is not disabled when only one power supply exists 
           
(BugID 4408237) 
 
. Please check 
          the current revision of the 
 Sun Fire 
          V880 Server Product Notes for more information.  
       
       | 
  
   
    | Remote System Control (RSC) Card | 
     
       98 
     | 
     
       102 
     | 
      | 
  
   
    | SEEPROM | 
     
       128 
     | 
     
       130 
     | 
      | 
  
   
    | System Status Assembly | 
     
       158 
     | 
     
       161 
     | 
      | 
  
   
    | Tape Drive | 
     
       172 
     | 
     
       176 
     | 
      |