This section provides the most common repair procedures for the 
  Netra t 1400/1405, which are included in the following manual:
   
    | Component | 
     
       Remove  
         
     | 
     
       Install 
     | 
    Tips | 
  
   
    | CD-ROM/DVD-ROM Drive | 
     
       8-4 
     | 
     
       8-5 
     | 
      | 
  
   
    | CPU Module | 
     
       9-1 
     | 
     
       9-2 
     | 
     
      
        - Tuning the ecache_scan_rate parameter of the Solaris cache scrubber 
          provides improved Ecache parity error protection on non-mirrored SRAM 
          UltraSPARC II-based systems (FIN I0755-1).
 
        - OS mapping versus physical location of CPU modules for E420R, E450, 
          U80 and Netra t1400/t1405 systems may lead to incorrect module replacement 
          (FIN I0749-1).
 
       
     | 
  
   
    | DC-to-DC Converter | 
     
       9-22 
     | 
     
       9-23 
     | 
    
      
        - Improper insertion of the DC-DC convertor module on certain systems 
          may cause burned pins on the mother board connector (FIN I0642-1).
 
       
     | 
  
   
    |  
       Disk Drive 
     | 
     
       8-1 
     | 
     
       8-3 
     | 
    
      
        - 18.2GB and 36GB IBM disk drives may be susceptible to early life failures 
          problem (FIN I0724-2).
 
       
     | 
  
   
    | Memory | 
     
       9-13 
     | 
     
       9-14 
     | 
      | 
  
   
    | Memory Riser Card | 
     
       9-15 
     | 
     
       9-16 
     | 
     
      
        - System initialization failures are sometimes being diagnosed incorrectly 
          due to an improperly installed Memory Riser card (FIN I0607-1). 
        
 
        - Failure to properly assemble the Memory Riser to the correct torque 
          setting can cause intermittent memory related system problems (FIN I0537-2).
 
       
     | 
  
   
    | NVRAM/TOD | 
     
       9-20 
     | 
     
       9-21 
     | 
      | 
  
   
    | PCI Card | 
     
       9-9 
     | 
     
       9-10 
     | 
     
      
        - Ultra 80 system board based systems may panic at boot time with certain 
          PCI Bus configurations (FIN I0665-1).
 
        - Systems based on the PSYCHO chipset panic with a PCI bus error (SRDB 
          40602). 
        
 
       
     | 
  
   
    | Power Supply | 
     
       7-1 
     | 
     
       7-3 
     | 
      | 
  
   
    | Power Distribution Board | 
     
       7-4 
     | 
     
       7-5 
     | 
      | 
  
   
    | System Board | 
     
       9-25 
     | 
     
       9-27 
     | 
     
      
        - Ultra 80 system board based systems may panic at boot time with certain 
          PCI Bus configurations (FIN I0665-1).
 
        - Improper insertion of the DC-DC convertor module on certain systems 
          may cause burned pins on the mother board connector (FIN I0642-1).
 
       
     | 
  
   
    | Tape Drive | 
     
       8-4 
     | 
     