| FIN | 
     
       Impl. 
     | 
    Components 
      Affected | 
    Description | 
  
   
    | I0569-1 | 
     
       R 
     | 
    Differential Ultra/Wide SCSI UDWIS/S (370-2443-02) | 
    UDWIS SBus Host Adapter with isp-fcode 1.28 can 
      cause "invalid command" during probe-scsi-all or boot -hv from 
      a StorEdge D1000. | 
  
   
    | I0552-1 | 
     
       C 
     | 
    Differential Ultra/Wide SCSI UDWIS/S (370-2443-0X) 
      Differential Fast/Wide SCSI DWIS/S (370-1704-0X) 
      Single-Ended Fast/Wide SCSI SWIS/S (370-1703-0X) | 
    SCSI devices (especially in a multi-hosted configuration) 
      may go offline after isp errors. | 
  
   
    | I0547-1 | 
     
       C 
     | 
    Differential Ultra/Wide SCSI UDWIS/S (370-2443-01) | 
    Intermittently, SCSI devices connected to a UDWIS 
      card may not be usable after a system boot or reboot. | 
  
   
    | I0545-1 | 
     
       C 
     | 
    n/a | 
    The StorEdge L1800 and L3500, robotics firmware 
      has dependencies to the DLT7000 firmware v95. | 
  
   
    | I0519-1 | 
     
       R 
     | 
    SBU Server Edition (794-7575-01) | 
    Networker may attempt to position a DLT7000 volume 
      to read the label before the drive has completed the load sequence. | 
  
   
    | I0498-1 | 
     
       R 
     | 
    DLT7000 Differential SCSI Tape Drive (370-3516-01) | 
    DLT Type III media may not be able to write in 
     | 
  
   
    | I0462-2 | 
     
       R 
     | 
     LibMON 2.0 ATL Multilingual CD (798-1365-01) 
      LibMON 2.0 Non-ATL Multilingual CD (798-0508-01) 
      LibMON 2.0 Multilingual Doc Set (855-5008-01) | 
    UPDATED FIN. StorEdge LibMON/LibAgent 2.0 does 
      not provide support for L280 and L11000 libraries. | 
  
   
    | I0448-1 | 
     
       C 
     | 
    DLT7000 Differential SCSI Tape Drive (370-3516-01) | 
    DLT 7000 drive Take-Up Leader and Cartridge Leader 
      misalignment may cause the unit to fail. | 
  
   
    | I0435-1 | 
     
       R 
     | 
    DLT 7000 Single-Ended SCSI Tape Drive (370-2847-0X) | 
    DLT7000s may exhibit poor performance due to 
      an incorrect st.conf file entry. | 
  
   
    | I0407-1 | 
     
       R 
     | 
    20/35GB DLT Cartridge Tape (370-2188-01) 
      DLT Cleaning Cartridge (370-2189-01) | 
    The Care and Inspection of DLT Cartridge Tapes. |