       FCO 
     | 
     
       Impl. 
     | 
    Components 
      Affected | 
    Description | 
  
  
    | A0194-1 | 
    
       U 
     | 
    Load Board (501-3142-01) | 
    Ultra Enterprise E6000 & E6500 system Load Boards can be susceptible to fatal resets. | 
  
   
    | A0182-1 | 
     
       C 
     | 
    18GB and 36GB IBM disk drives | 
    18GB and 36GB IBM disk drives experiencing 
      high failure rate in high humidity and high temperature environments. | 
  
  
    | A0179-2 | 
    
       C 
     | 
    Power Cords (530-2265-02 or less, 530-2674-01,
      530-2266-02 or less, 530-2568-02 or less, 530-2567-02 or less, 530-2675-01)
 | 
    Ultra Enterprise E5x00 and E6x00 systems, and Delorean 72-inch
      Rack power cords with pre-tinned wires violates UL 1950 standard. | 
  
   
    | A0171-1 | 
     
       U 
     | 
    POST, PRTDIAG | 
    Enterprise Servers E4500, E5500 and E6500 
      may report false error messages when running POST, PRTDIAG, or during system 
      boot-up. | 
  
   
    | A0163-1 | 
     
       C 
     | 
    Differential Ultra/Wide SCSI, UDWIS/S 
      (370-2443-01) | 
    Systems with large quantities of UDWIS/SBus 
      Host Adapters installed may not come up after reboot due to miscommunication 
      between the SCSI host and the target. Large configurations with many UDWIS/SBus 
      Host Adapter cards are more vulnerable due to higher probability of encountering 
      the reboot problem.  | 
  
   
    | A0151-1 | 
     
       U 
     | 
    FDDI 5.0 SAS/DAS (370-3142, 370-3143, 
      370-2339, 370-2340); SPARCcenter 2000 | 
    SPARCcenter 2000 will fail Power-On Self-Test 
      (POST) in extended mode with FDDI 5.0 SBus controllers installed with an 
      unexpected data_access_exception error which could cause the system to Watchdog 
      Reset. | 
  
   
    | A0139-1 | 
     
       U 
     | 
     
       PGX PCI-based 8-bit Frame Buffer (370-2256-02) 
     | 
     
       Systems with a PGX PCI-based 8-bit Frame Buffer may display a vertical 
        black stripe when running the OpenWindows environment. This occurs only 
        with frame buffers with an Fcode version 1.09 (determined by reading the 
        label on the EPROM located at U4 on the frame buffer: 113-377-1-109). 
     | 
  
   
    | A0138-1 | 
     
       C 
     | 
    SBus/FC SOC+ Host Adapters | 
    SBus/FC SOC+ Host Adapters may experience 
      recoverable data transfer read errors. This can result in individual user 
      applications, like Oracle, to stop running. | 
  
   
    | A0136-1 | 
     
       U 
     | 
    Disk Board (501-3113-02) | 
    At system power up, the disk board (501-3113-02) 
      does not turn on. This problem may be seen in the field if one of the following 
      two scenario's occur: (1) a disk board is added to a system with a pre-existing 
      disk board or (2) a system is upgraded by adding other modules (CPU, I/O 
      boards, etc). POST will fail with 'SCSI_VDD' error message in DIAG mode. | 
  
   
    | A0133-1 | 
     
       M 
     | 
    Terminal Concentrator (370-1434-02)  | 
    When the Annex Terminal Concentrator is 
      powered on, it sends a break signal to each port, bringing down any attached 
      Sun Servers to the OBPROM prompt. Although any attached server can survive 
      a power failure on the Annex Terminal Concentrator, the servers will be 
      interrupted when power is restored to the Terminal Concentrator unless the 
      serial cables are disconnected while the Annex Terminal Concentrator is 
      performing its POST. |