| BYTE | 
      DESCRIPTION | 
    
     
      12 
        - | 
      - 
        13 | 
      Additional Sense Code (ASC) 
        Additional Sense Code Qualifier (ASCQ) | 
    
     
      | 00 | 
      00 | 
      No additional sense information | 
    
     
      | 00 | 
      01 | 
      Filemark detected | 
    
     
      | 00 | 
      02 | 
      End of partition/medium detected | 
    
     
      | 00 | 
      03 | 
      Setmark detected | 
    
     
      | 00 | 
      04 | 
      Begining-of-Partition/Medium detected | 
    
     
      | 00 | 
      05 | 
      End of data detected | 
    
     
      | 00 | 
      11 | 
      Audio play operation in progress | 
    
     
      | 00 | 
      12 | 
      Audio play operation paused | 
    
     
      | 00 | 
      13 | 
      Audio play operation successfully completed | 
    
     
      | 00 | 
      14 | 
      Audio play operation stopped due to error | 
    
     
      | 00 | 
      15 | 
      No current audio status to return | 
    
     
      | 01 | 
      00 | 
      No index/sector signal | 
    
     
      | 02 | 
      00 | 
      No seek complete | 
    
     
      | 03 | 
      00 | 
      Peripheral device write fault | 
    
     
      | 03 | 
      01 | 
      No write current | 
    
     
      | 03 | 
      02 | 
      Excessive write errors | 
    
     
      | 04 | 
      00 | 
      Logical unit not ready, cause not reportable | 
    
     
      | 04 | 
      01 | 
      Logical unit is in progress of becoming ready | 
    
     
      | 04 | 
      02 | 
      Logical unit not ready, initiating command required | 
    
     
      | 04 | 
      03 | 
      Logical unit not ready, manual intervention required | 
    
     
      | 04 | 
      04 | 
      Logical unit not ready, format in progress | 
    
     
      | 05 | 
      00 | 
      Logical unit does not respond to selection | 
    
     
      | 06 | 
      00 | 
      No reference position found | 
    
     
      | 07 | 
      00 | 
      Multiple peripheral devices selected | 
    
     
      | 08 | 
      00 | 
      Logical unit communication failure | 
    
     
      | 08 | 
      01 | 
      Logical unit communication time out | 
    
     
      | 08 | 
      02 | 
      Logical unit communication parity error | 
    
     
      | 09 | 
      00 | 
      Track following error | 
    
     
      | 09 | 
      01 | 
      Tracking servo failure | 
    
     
      | 09 | 
      02 | 
      Focus servo failure | 
    
     
      | 09 | 
      03 | 
      Spindle servo failure | 
    
     
      | 0a | 
      00 | 
      Error log overflow | 
    
     
      | 0c | 
      00 | 
      Write error | 
    
     
      | 0c | 
      01 | 
      Write error recovered with auto reallocation | 
    
     
      | 0c | 
      02 | 
      Write error - auto reallocation failed | 
    
     
      | 10 | 
      00 | 
      ID CRC or ECC error | 
    
     
      | 11 | 
      00 | 
      Unrecovered read error | 
    
     
      | 11 | 
      01 | 
      Read retries exhausted | 
    
     
      | 11 | 
      02 | 
      Error log too long to correct | 
    
     
      | 11 | 
      03 | 
      Multiple read errors | 
    
     
      | 11 | 
      04 | 
      Unrecovered read error - auto reallocate failed | 
    
     
      | 11 | 
      05 | 
      L-EC uncorrectable error | 
    
     
      | 11 | 
      06 | 
      CIRC unrecovered error | 
    
     
      | 11 | 
      07 | 
      Data resynchronization error | 
    
     
      | 11 | 
      08 | 
      Incomplete block read | 
    
     
      | 11 | 
      09 | 
      No gap found | 
    
     
      | 11 | 
      0a | 
      Miscorrected error | 
    
     
      | 12 | 
      00 | 
      Address mark not found for ID field | 
    
     
      | 13 | 
      00 | 
      Address mark not found for data field | 
    
     
      | 14 | 
      00 | 
      Recorded entity not found | 
    
     
      | 14 | 
      01 | 
      Record not found | 
    
     
      | 15 | 
      00 | 
      Random positioning error | 
    
     
      | 15 | 
      01 | 
      Mechanical positioning error | 
    
     
      | 15 | 
      02 | 
      Positioning error detected by read of medium | 
    
     
      | 16 | 
      00 | 
      Data synchronization mark error | 
    
     
      | 17 | 
      00 | 
      Recovered data with no error correction applied | 
    
     
      | 17 | 
      01 | 
      Recovered data with retries | 
    
     
      | 17 | 
      02 | 
      Recovered data with positive head offset | 
    
     
      | 17 | 
      03 | 
      Recovered data with negative head offset | 
    
     
      | 17 | 
      04 | 
      Recovered data with retries and/or CIRC applied | 
    
     
      | 17 | 
      05 | 
      Recovered data using previous sector | 
    
     
      | 17 | 
      06 | 
      Recovered data without ECC - Data auto-reallocated | 
    
     
      | 18 | 
      00 | 
      Recovered data with error correction applied | 
    
     
      | 18 | 
      01 | 
      Recovered data with error correction & retries applied | 
    
     
      | 18 | 
      02 | 
      Recovered data with ECC and/or retries | 
    
     
      | 18 | 
      03 | 
      Recovered data with CIRC | 
    
     
      | 18 | 
      04 | 
      Recovered data with LEC | 
    
     
      | 19 | 
      00 | 
      Defect list error | 
    
     
      | 19 | 
      01 | 
      Defect list not available | 
    
     
      | 19 | 
      02 | 
      Defect list error in primary list | 
    
     
      | 19 | 
      03 | 
      Defect list error in grown list | 
    
     
      | 1a | 
      00 | 
      Parameter list length error | 
    
     
      | 1b | 
      00 | 
      Synchronous data transfer error | 
    
     
      | 1c | 
      00 | 
      Defect list not found | 
    
     
      | 1c | 
      01 | 
      Primary defect list not found | 
    
     
      | 1c | 
      02 | 
      Grown defect list not found | 
    
     
      | 1d | 
      00 | 
      Miscompare during verify operation | 
    
     
      | 1e | 
      00 | 
      Recovered ID with ECC correction | 
    
     
      | 20 | 
      00 | 
      Invalid command operation code | 
    
     
      | 21 | 
      00 | 
      Logical block address out of range | 
    
     
      | 21 | 
      01 | 
      Invalid element address | 
    
     
      | 22 | 
      00 | 
      Illegal function for device type | 
    
     
      | 24 | 
      00 | 
      Invalid field in CDB | 
    
     
      | 25 | 
      00 | 
      Logical unit not supported | 
    
     
      | 26 | 
      00 | 
      Invalid field in parameter list | 
    
     
      | 26 | 
      01 | 
      Parameter not supported | 
    
     
      | 26 | 
      02 | 
      Parameter value invalid | 
    
     
      | 26 | 
      03 | 
      Threshold parameters not supported | 
    
     
      | 27 | 
      00 | 
      Write protected | 
    
     
      | 28 | 
      00 | 
      Not ready to ready transition | 
    
     
      | 28 | 
      01 | 
      Import / Export element accessed | 
    
     
      | 29 | 
      00 | 
      Power-On, reset, or bus device reset occurred | 
    
     
      | 2a | 
      00 | 
      Parameters changed | 
    
     
      | 2a | 
      01 | 
      Mode parameters changed | 
    
     
      | 2a | 
      02 | 
      Log parameters changed | 
    
     
      | 2b | 
      00 | 
      Copy cannot execute since host cannot disconnect | 
    
     
      | 2c | 
      00 | 
      Command sequence error | 
    
     
      | 2c | 
      01 | 
      Too many windows specified | 
    
     
      | 2c | 
      02 | 
      Invalid combination of windows specified | 
    
     
      | 2d | 
      00 | 
      Overwrite error on update in place | 
    
     
      | 2f | 
      00 | 
      Commands cleared by another initiator | 
    
     
      | 30 | 
      00 | 
      Incompatible medium installed | 
    
     
      | 30 | 
      01 | 
      Cannot read medium - unknown format | 
    
     
      | 30 | 
      02 | 
      Cannot read medium - incompatible format | 
    
     
      | 30 | 
      03 | 
      Cleaning cartridge installed | 
    
     
      | 31 | 
      00 | 
      Medium format corrupted | 
    
     
      | 31 | 
      01 | 
      Format command failure | 
    
     
      | 32 | 
      00 | 
      No defect spare location available | 
    
     
      | 32 | 
      01 | 
      Defect list update failure | 
    
     
      | 33 | 
      00 | 
      Tape length error | 
    
     
      | 36 | 
      00 | 
      Ribbon/Ink/Toner faliure | 
    
     
      | 37 | 
      00 | 
      Rounded parameter | 
    
     
      | 39 | 
      00 | 
      Saving parameters not supported | 
    
     
      | 3a | 
      00 | 
      Medium not present | 
    
     
      | 3b | 
      00 | 
      Sequential positioning error | 
    
     
      | 3b | 
      01 | 
      Tape position error at begining of medium | 
    
     
      | 3b | 
      02 | 
      Tape position error at end of medium | 
    
     
      | 3b | 
      03 | 
      Tape or electronic vertical forms unit not ready | 
    
     
      | 3b | 
      04 | 
      Slew failure | 
    
     
      | 3b | 
      05 | 
      Paper jam | 
    
     
      | 3b | 
      06 | 
      Failed to sense top of form | 
    
     
      | 3b | 
      07 | 
      Failed to sense bottom of form | 
    
     
      | 3b | 
      08 | 
      Reposition error | 
    
     
      | 3b | 
      09 | 
      Read past end of medium | 
    
     
      | 3b | 
      0a | 
      Read past begining of medium | 
    
     
      | 3b | 
      0b | 
      Position past end of medium | 
    
     
      | 3b | 
      0c | 
      Position past begining of medium | 
    
     
      | 3b | 
      0d | 
      Medium destination element full | 
    
     
      | 3b | 
      0e | 
      Medium source element empty | 
    
     
      | 3d | 
      00 | 
      Invalid bits in identify message | 
    
     
      | 3e | 
      00 | 
      Logical unit has not self configured yet | 
    
     
      | 3f | 
      00 | 
      Target operating conditions have changed | 
    
     
      | 3f | 
      01 | 
      Microcode has been changed | 
    
     
      | 3f | 
      02 | 
      Changed operating definition | 
    
     
      | 3f | 
      03 | 
      Inquiry data has changed | 
    
     
      | 40 | 
      nn | 
      Diagnostic failure on component nn (80h-ffh) | 
    
     
      | 41 | 
      00 | 
      Data path failure | 
    
     
      | 42 | 
      00 | 
      Power-On or Self-Test failure | 
    
     
      | 43 | 
      00 | 
      Message error | 
    
     
      | 44 | 
      00 | 
      Internal target failure | 
    
     
      | 45 | 
      00 | 
      Select/Reselect failure | 
    
     
      | 46 | 
      00 | 
      Unsuccessful soft reset | 
    
     
      | 47 | 
      00 | 
      SCSI parity error | 
    
     
      | 48 | 
      00 | 
      Initiator detected error message received | 
    
     
      | 49 | 
      00 | 
      Invalid message error | 
    
     
      | 4a | 
      00 | 
      Command phase error | 
    
     
      | 4b | 
      00 | 
      Data phase error | 
    
     
      | 4c | 
      00 | 
      Logical unit failed self configuration | 
    
     
      | 4e | 
      00 | 
      Overlapped commands attempted | 
    
     
      | 50 | 
      00 | 
      Write append error | 
    
     
      | 50 | 
      01 | 
      Write append position error | 
    
     
      | 50 | 
      02 | 
      Position error related to timing | 
    
     
      | 51 | 
      00 | 
      Erase failure | 
    
     
      | 52 | 
      00 | 
      Cartridge fault | 
    
     
      | 53 | 
      00 | 
      Media load/eject failed | 
    
     
      | 53 | 
      01 | 
      Unload tape failure | 
    
     
      | 53 | 
      02 | 
      Medium removal prevented | 
    
     
      | 54 | 
      00 | 
      SCSI to host system interface failure | 
    
     
      | 55 | 
      00 | 
      System resource failure | 
    
     
      | 57 | 
      00 | 
      Unable to recover table-of-contents | 
    
     
      | 58 | 
      00 | 
      Generation does not exist | 
    
     
      | 59 | 
      00 | 
      Updated block read | 
    
     
      | 5a | 
      00 | 
      Operator request or state change input | 
    
     
      | 5a | 
      01 | 
      Operator medium removal request | 
    
     
      | 5a | 
      02 | 
      Operator selected write protect | 
    
     
      | 5a | 
      03 | 
      Operator selected write permit | 
    
     
      | 5b | 
      00 | 
      Log exception | 
    
     
      | 5b | 
      01 | 
      Threshold condition met | 
    
     
      | 5b | 
      02 | 
      Log counter at maximum | 
    
     
      | 5b | 
      03 | 
      Log list codes exhausted | 
    
     
      | 5c | 
      00 | 
      RPL status change | 
    
     
      | 5c | 
      01 | 
      Spindles synchronized | 
    
     
      | 5c | 
      02 | 
      Spindles not synchronized | 
    
     
      | 60 | 
      00 | 
      Lamp failure | 
    
     
      | 61 | 
      01 | 
      Unable to acquire video | 
    
     
      | 61 | 
      02 | 
      Out of focus | 
    
     
      | 62 | 
      00 | 
      Scan head positioning error | 
    
     
      | 63 | 
      00 | 
      End of user area encountered on this track | 
    
     
      | 64 | 
      00 | 
      Illegal mode for this track | 
    
     
       
       | 
       
       | 
       
       | 
    
     
      | 80 | 
      80 | 
      Vendor unique ASC and ASCQ | 
    
     
      | through | 
       
       | 
    
     
      | ff | 
      ff | 
      Vendor unique ASC and ASCQ |