Solution Type
Technical Instruction Sure
Solution
1495913.1
:
How to Replace a Sun Server X3-2L(X4270M3) Motherboard assembly
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
Oracle Confidential (PARTNER). Do not distribute to customers.
Reason: FRU CAP
Applies to:
Sun Server X3-2L - Version Not Applicable to Not Applicable [Release N/A]
x86_64
Goal
How to Replace a Sun Server X3-2L(X4270M3) Motherboard assembly
Fix
CAP PROBLEM OVERVIEW: MOTHERBOARD ASSEMBLY REPLACEMENT
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
Sun Server X3-2L Server Training.
Note: The removal/insertion CPU tool is new for the Sandy Bridge M3 product lines. If you have not used this new tool before please make yourself familiar before attempting to use on-site. The tool is not intuitive so reference the service manual before attempting this service action.
TIME ESTIMATE: 90 minutes
TASK COMPLEXITY: 3-FRU
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications and OS. Then power off the server and remove the AC power cords from the system.
A data backup is not a prerequisite but is a wise precaution.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Prepare the server for service.
- Power off the server and disconnect the power cords from the power supplies.
- Extend the server to the maintenance position in the rack.
- Attach an anti-static wrist strap.
- Remove the top cover.
- Remove the Air Baffle
2. Remove all of the Fan Modules
- Open the Server Fan Door. Slide the fan door latches forward and swing the door up to the open position.
- Using your thumb and forefinger, loosen the captive screw that secures the faulty fan module in the chassis (use a No. 2 Phillips screwdriver if it is too tight to loosen with your fingers).
- Grasp both the captive screw and the opposite end of the module and lift the fan module straight up and out of the chassis (do not rock it back and forth), and set it aside on an antistatic mat.
3. Remove the Power Supplies
- Gain access to the rear of the server where the power supplies are located.
- Release the cable management arm (CMA).If one is installed, Press and hold the CMA release tab.
- Rotate the cable management arm out of the way so that you can access the power supply.
- Disconnect the power cord from each power supply.
- For each of the power supplies grasp the power supply handle and push the power supply latch to the left.
- Pull the power supply out of the chassis.
4. Remove the Storage Drive Cables and SAS expander from a SAS/SATA configuration.
- If you are removing the SAS/SATA cables from a server with twenty-four 2.5-inch storage drives, remove the server's front fan assembly door cover.
- Using a No. 1 Phillips screwdriver, remove the two screws (one on each side of the chassis) that secure the fan assembly door.
- Slide the fan assembly door toward the rear of the server, and lift and remove the door from the chassis.
- Disconnect SAS/SATA cables from the SAS expander module making note of their locations so that they may be re-connected in the same positions.
- To disconnect the HBA cable and the SAS/SATA cables from the SAS expander module, press the latch, and then pull out to disengage each cable from the SAS expander module.
- To disconnect the SAS/SATA cables from the front storage drive backplane and the SAS expander module, press the latch, and then pull out to disengage the cables from each storage drive backplane.
- If they are installed disconnect the rear storage drive SAS cables from the SAS expander module, press the latch, and then pull up to disengage the disk drive SAS drive cable from the SAS expander module.
- Remove the SAS expander module from the chassis.
- Locate and loosen the four black push pins that secure the SAS expander module to the server's chassis. Loosen each push pin by pulling up on the pin until it clicks into the open position
- Grasp the sides of the SAS expander module, and gently lift the module to disengage the module from the chassis connector
- Place the SAS expander module on an antistatic mat.
5. Remove any installed PCIe cards.
- For each PCIe card make a note of where the PCIe cards are installed so that they can be re-installed in the same locations.
- Unplug all data cables from the PCIe card
- Rotate the PCIe card locking mechanism, and then lift up on the PCIe card to disengage it from the motherboard connectors.
- Place the PCIe card on an antistatic mat.
6. Remove the Motherboard from the Chassis.
- Disconnect the ribbon cables from the left front I/O module and right front I/O modules.
- Disconnect the LED cable between the motherboard to the disk backplane.
- Disconnect the signal cable from the server intrusion switch.
- Remove the server's mid-wall by using a No. 2 Phillips screwdriver, remove the two screws on each side of the chassis that secure the mid-wall to the chassis.
- Using a No. 2 Phillips screwdriver, loosen the four green captive screws that secure the chassis mid-wall to the bottom of the chassis.
- Lift the mid-wall out of the chassis
- Remove the motherboard from the server's chassis by carefully sliding the motherboard forward, and then lifting it out of the chassis.
- Place it on an anti-static mat, and next to the replacement motherboard.
- Remove the following reusable components from the motherboard and install them on the replacement motherboard.
- Internal USB flash drives, remove by grasping the flash drive and pulling straight up.
- Make sure to install each USB flash drive in the same orientation to ensure that it is properly positioned in the USB port.
- DDR3 DIMMs. Perform a one-to-one replacement of the DIMMs from the current motherboard to the new motherboard to reduce the possibility of the DIMMs being installed into the wrong slots. If the DIMMs are not populated correctly the server performance may suffer and some DIMMs might not be used.
- To remove the DIMMs rotate both DIMM socket ejectors outward as far as they will go.
- Carefully lift the DIMM straight up to remove it from the socket.
- Install the DIMMs in the replacement Motherboard by ensuring that the ejector tabs of the DIMM slots are in the open position.
- Then align the notch in the DIMM with the key in the connector.
- Push the DDR3 DIMM into the connector until the ejector tabs lock the DIMM in place.
7. Remove the CPU(s) from the current Motherboard. Perform the following steps for each installed CPU.
- Gently press down on the top of the heat sink to counteract the pressure of the captive spring-loaded screws that secure the heat sink to the motherboard. Loosen the four Phillips captive screws in the heat sink for the faulty CPU. Using a No. 2 Phillips screwdriver turn the screws counter clockwise alternately one and one half turns until they are fully removed.
- To separate the heat sink from the top of the CPU, gently wiggle the heat sink left and right, while pulling upward. A thin layer of thermal compound separates the heat sink and the CPU. This compound also acts as an adhesive. Note –Do not allow the thermal compound to contaminate the work space or other components.
- Place the heat sink upside down on a flat surface.
- Use an alcohol pad to clean the thermal grease from both the bottom of the heat sink and the top of the CPU. Caution –Handle CPU socket pins with extreme care. CPU and socket pins are very fragile. A light touch can bend the CPU socket pins and damage the board beyond repair.
- Disengage both CPU release levers by pushing down and moving it to the side away from the CPU, and then rotating the levers upward starting with the right lever (when viewing server from the front). Repeat with left lever.
- Lift the CPU pressure frame up to the fully open position.
- This platform requires a custom removal/insertion CPU tool that comes with the CPU replacement FRU. Push the removal/insertion tool button in the top center to unlock the tool. Place the removal/insertion tool on top of the CPU. Properly position the tool over the CPU socket and lower it into place over the CPU socket. Ensure that the tool and CPU key corners are aligned. To properly position the tool over the CPU socket, rotate the tool until the green triangle on the side of the tool is facing the front of the server and it is over the left side of the CPU socket when viewing the server from the front.
- Click the tab on the removal/insertion tool to secure the tool to the CPU. Press the release lever on the tool to release the center button and engage the CPU. An audible click indicates that the CPU is engaged.
- Lift the CPU out of the socket while it is still attached to the removal/insertion tool. Grasp the tool by its sides and remove it from the server. Turn the tool upside down and verify that it contains the CPU.
- Leave the CPU in the removal/insertion tool and proceed to next step to install it into the new Motherboard.
8. Re-install the CPU(s) onto the new Motherboard. Perform the following steps for each CPU.
- Ensure that the two CPU socket release levers are in the fully open position and that the CPU pressure frame is in the fully open position.
- The CPU removal/insertion tool should have the CPU installed in it from the previous step after removing it from the current motherboard.
- Properly position the tool over the CPU socket and lower it into place. Carefully align the CPU over the CPU socket. Ensure that the notches on the sides of the CPU align with the keys on the socket. To properly position the tool in the CPU socket, rotate the tool until the green triangle on the side of the tool is facing the front of the server and it is over the left side of the CPU socket (when viewing server from the front) and lower the tool onto the CPU socket.
- Press the center button in the tool down to release the CPU so that it is placed in the CPU socket. Caution – Do not press down on the CPU. Irreparable damage to the CPU or motherboard might occur from excessive downward pressure. Do not forcibly seat the CPU into the socket. Excessive downward pressure might damage the socket pins.
- Remove the processor removal/insertion tool.
- Visually check the alignment. Close the pressure frame ensure that the pressure frame sits flat around the periphery of the CPU.
- Engage the release levers by rotating them downward and slipping them under the catch left first and then the right one.
9.Install the CPU Heat Sink Assembly.
- Use the syringe to apply approximately 0.1 ml of thermal grease to the center of the top of the CPU. Do not distribute the grease.
- Inspect the heat sink for dust and lint. Clean if necessary.
- Carefully position the heat sink on the CPU, aligning it with the mounting posts to reduce movement after it makes initial contact with the layer of thermal grease. Caution – When handling the heat sink, be careful not to get the thermal compound grease on your fingers so as not to transfer the grease to other server components.
- Lower the heat sink onto the CPU. Caution – Avoid moving the heat sink after it has contacted the top of the CPU. Too much movement could disturb the layer of thermal compound, causing voids, and leading to ineffective heat dissipation and component damage.
- Tighten the Phillips screws alternately one-half turn until they are fully seated.
10. Re-install the Motherboard into the Chassis.
- Carefully lift and place the motherboard assembly into the chassis. Tilt the motherboard to the right side to fit under the power supply assembly, level the motherboard and place it into the server chassis, then slide it to the rear of the server to engage the mushroom standoffs.
- Install the mid-wall into the chassis.
- Lift and place the mid-wall into the chassis.
- Using a No. 2 Phillips screwdriver, tighten the four green captive screws that secure the mid-wall to the bottom of the chassis.
- Using a No. 2 Phillips screwdriver, insert and tighten the two screws on each side of the chassis to secure the mid-wall in the chassis.
- Reconnect the server intrusion switch cable to the motherboard.
- Reconnect the signal cable from the storage drive backplane to the motherboard.
- Reconnect the ribbon cables from left and right LED/USB indicator modules to the motherboard.
11. Re-install the PCIe cards.
- Make sure to re-install the cards into the same locations from which they were removed.
- If necessary, remove the PCIe filler panel from the slot.
- Insert the PCIe card into the correct slot, and rotate the PCIe locking mechanism to secure the PCIe card in place.
- Reconnect the cables to the PCIe card that you unplugged during the removal procedure.
12. Re-install the Storage Drive Cables and SAS expander from a SAS/SATA configuration.
- Install the SAS expander module.
- Lower the SAS expander module into the server chassis, and gently push down on the module to engage the chassis connector.
- Push down on the four black push pins to secure the SAS expander module to the server's chassis.
- Connect the HBA cable and SAS cables to the SAS expander module
- Route the SAS cables from the disk backplane between the fan modules and between processors and DIMMs in the cable trough.
- If present Install the cable connectors into the rear-mounted storage drive backplane.To reconnect the rear-mounted storage drive SAS cables to the SAS expander module, plug each cable into its top SAS expander module connector until you hear an audible click.
- Making sure to reconnect the cables in the same order as they were previously installed reconnect the SAS/SATA cables to the SAS expander module. To reconnect the HBA cable and the SAS/SATA cables to the SAS expander module, plug each cable into its SAS expander module connector until you hear an audible click.
- To reconnect the front storage drive SAS/SATA cables to the SAS expander module, plug each cable into its SAS expander module connector until you hear and audible click
- Place the cables into cable tie-downs, and secure them with the tie-downs
13. Re-install the Power Supplies and Fans
- For each power supply align the power supply with the empty power supply bay, then Slide the power supply into the bay until it is fully seated.
- Open the fan door and install the fan modules into the server.
- Press down on the fan module and apply firm pressure to fully seat the fan module.
- Close the fan door.
14. Return the Server to operation
- Replace the Air Baffle
- Replace the top cover
- Remove any anti-static measures that were used.
- Return the server to it's normal operating position within the rack.
- Re-install the AC power cords and any data cables that were removed.
- Power on server. Verify that the Power/OK indicator led lights steady on.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
REFERENCE INFORMATION:
Sun Server X3-2L Documentation
http://docs.oracle.com/cd/E23393_01/index.html