Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1491899.1
Update Date:2012-09-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  1491899.1 :   SL3000/SL8500 - Port Usage to Enable Remote Site Firewall  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Goal
Fix


Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

 Which port must be enabled if the SLConsole has to reach an SL3000 through a remote site's firewall?

Fix

Port_22 is used for SL Console to establish a secure connection to the library.

Required Ports:

50001-50016; HSC and ACSLS

161-162; SNMP

22; SLC and CLI Communication


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback