In this Document
Applies to:Sun Netra 210 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalNetra 210 - How to Remove and Replace the Battery FixDISPATCH INSTRUCTIONS OBTAIN CUSTOMER ACCEPTANCE WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE: The battery used on the Netra 210 server system board is a type CR2032 or compatible equivalent. Removing the Battery 1. Power off the server, remove the server from the rack, and remove the top cover and airduct. 2. Locate the battery. The battery is located at the left front of the system board. 3. Press the tab at the side of the battery to release it. 4. Lift the battery up and out of the socket. Installing the Battery 1. Remove the server from the rack and remove the top cover. 3. Remove the replacement battery from its shipping container and antistatic packaging. 4. Press the battery down into the socket, plus (+) side up. 5. Install the air duct and top cover, install the server into the rack, power on the server, and verify the installation.
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://support.oracle.com/handbook_private/Systems/Netra_210/components.html
ADDITIONAL COMMENTS:
Attachments This solution has no attachment |
||||||||||||||
|