Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1489895.1
Update Date:2012-09-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1489895.1 :   How to Remove and Replace Netra 210 Battery:ATR:1489895.1:1  


Related Items
  • Sun Netra 210 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun Netra 210 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

  Netra 210 - How to Remove and Replace the Battery

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Netra 210 product training is desirable but not required, as the part is a CRU

TASK COMPLEXITY: 1

TIME ESTIMATE: 50 minutes

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW: Battery failure

OBTAIN CUSTOMER ACCEPTANCE

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE:

The battery used on the Netra 210 server system board is a type CR2032 or compatible equivalent.

Removing the Battery

1. Power off the server, remove the server from the rack, and remove the top cover and airduct.

2. Locate the battery. The battery is located at the left front of the system board.

3. Press the tab at the side of the battery to release it.

4. Lift the battery up and out of the socket.

Caution – Do not power on the server without the battery installed.

Installing the Battery

1. Remove the server from the rack and remove the top cover.

2. Locate where the battery installs. The battery installs at the left front of the system board.

3. Remove the replacement battery from its shipping container and antistatic packaging.

4. Press the battery down into the socket, plus (+) side up.

5. Install the air duct and top cover, install the server into the rack, power on the server, and verify the installation.


WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:


Restart software applications per applicable administration guides to resume system operation.


PARTS NOTE: Include Battery Unit location:

https://support.oracle.com/handbook_private/Systems/Netra_210/components.html


ADDITIONAL COMMENTS:

Please refer to the Netra 210 Server Service Manual: http://docs.oracle.com/cd/E19102-01/n210.srvr/819-2750-10/819-2750-10.pdf

 


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback