![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Technical Instruction Sure Solution 1489841.1 : How to Remove and Replace a Netra 210 PCI Card:ATR:1489841.1:0
In this Document
Applies to:Sun Netra 210 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. GoalNetra 210 - How to Remove and Replace PCI Card FixDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Netra 210 product training is desirable but not required, as the part is a CRU TIME ESTIMATE: 30 minutes TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: PROBLEM OVERVIEW: Faulty PCI Card
The following procedures describe how to remove and install individual PCI cards into the Netra 240 server. Removing a PCI Card1.Power off the server. 5. Completely remove the air duct. 6. Locate the PCI card. 7. Loosen the PCI card thumbscrew at the chassis rear panel. 10. Remove the PCI card from the slot.
Installing a PCI Card1. Locate where the PCI card installs. The PCI card installs at the left rear of the chassis. 2. Loosen the PCI card thumbscrew at the chassis rear panel. 3. Rotate the PCI card latch clockwise. 6. Remove the PCI card from its shipping container and antistatic packaging. 7. Install the PCI card into the slot. 8. Rotate the PCI card latch counter-clockwise so that it holds the PCI card in place.
OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO Bring system back up to a functioning state. PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Netra_210/components.html REFERENCE INFORMATION: Please refer to the Netra 210 Server Service Manual: http://docs.oracle.com/cd/E19102-01/n210.srvr/819-2750-10/819-2750-10.pdf
Attachments This solution has no attachment |
||||||||||||||||||
|