![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1489840.1 : How To Remove and Replace Netra 210 Memory DIMM:ATR:1489840.1:1
In this Document
Applies to:Sun Netra 210 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalNetra 210 - How To Remove and Replace Netra 240 Memory DIMM FixDISPATCH INSTRUCTIONS Removing Memory 1. Power off the server, remove the server from the rack, and remove the top cover and airduct. 3. Press down on the ejector levers at both ends of the memory module. 4. Lift the memory straight up and out of the socket. 5. Set the memory aside on an antistatic mat. 6. Repeat Step 3 to Step 5 for each memory module to be removed. Installing Memory 1. Locate where the memory installs. The memory installs in matched pairs near the center of the system board, just right of the CPU. For each CPU, install the first matched pair in Bank0 (B0). Install the second matched pair in Bank1 (B1). 2. Remove one memory module from its shipping container and antistatic packaging. 3. Position the memory over the respective slot, with the notch in the memory aligning to the key of the slot. 4. Press the memory down into the slot firmly until it clicks into place. 5. Repeat Step 3 to Step 5 for each memory module to be installed. 6. Install the air duct and top cover, install the server into the rack, power on the server, and verify the installation OBTAIN CUSTOMER ACCEPTANCE Bring system back up to a functioning state. PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Netra_210/components.html
REFERENCE INFORMATION:
Attachments This solution has no attachment |
||||||||||||||
|