![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Technical Instruction Sure Solution 1488741.1 : How to Remove and Replace a Sun Ultra 45 Workstation Battery:ATR:1488741.1:0
In this Document
Applies to:Sun Ultra 45 Workstation - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. GoalSun Ultra 45 Workstation - How to Remove and Replace a Sun Ultra 25 Workstation Battery Fix DISPATCH INSTRUCTIONS Sun Ultra 45 Workstation product training is desirable but not required. TIME ESTIMATE: 45 mins TASK COMPLEXITY: 0 WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: A data backup is not a pre-requisite but is a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?: Battery The battery powers the server’s clock. Note - The Workstation does not function without the battery. TABLE 3-2 lists the battery specifications.
Removing the BatteryThe battery is located on the System Board. 1. Power off the system and attach an antistatic wrist strap. Open and position the chassis, and remove the access panel. 2. Release the battery by pressing the battery clip away from the battery until the battery shifts out of the battery socket 3. Remove the battery. Note - The Workstation does not function without the battery. Installing the BatteryThe battery fits directly into a socket on the motherboard. There are no additional fasteners or cables. 1. Position the battery over the battery socket with the plus (+) side up 2. Press the battery down into the socket until the battery clicks into place. 3. Reassemble the workstation, power on the system, and verify the battery installation.
Restart software applications per applicable administration guides to resume system operation. PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Ultra45/components.html
REFERENCE INFORMATION: Please refer to the Sun Ultra 45 Workstation Service and Diagnostics Manual: http://docs.oracle.com/cd/E19127-01/ultra25.ws/819-1892-12/819-1892-12.pdf Attachments This solution has no attachment |
||||||||||||||||||||||||
|