Solution Type Technical Instruction Sure Solution 1488547.1 : How to Remove and Replace Sun Blade 1500 memory DIMM:ATR:1488547.1:1
In this Document
Applies to:Sun Blade 1500 Workstation - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. GoalSun Blade 1500, How to Remove and Replace memory DIMM Fix
DISPATCH INSTRUCTIONS OBTAIN CUSTOMER ACCEPTANCE WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE: Removing the DIMMs Caution – DIMM memory is installed in pairs. However, if you replace a single DIMM, the installed part must be identical to the one removed. Caution – Handle the DIMMs along the outside edges. Do not handle the DIMM along the gold contact edge. Do not touch DIMM components or other metal parts. 1.Power off the workstation and open the chassis. Note – Your system’s DIMM cooling duct might not have two tines at the front end. The absence of these tines does not affect the functionality of the duct. 5. Release the desired DIMM. Simultaneously press down on both ejector levers at the ends of the DIMM to unlock the DIMM from the DIMM slot 6. Lift the DIMM straight out of the DIMM slot. Caution – Handle the DIMMs along the outside edges. Do not handle the DIMM along the gold edge. Do not touch DIMM components or other metal parts. Always wear a antistatic wrist strap when handling DIMMs. Caution – Do not lift the DIMM out at an angle as it might damage the DIMM slot. 7. Set the DIMM aside on an antistatic mat.
Installing the DIMMs Caution – If you are installing additional memory, remember that DIMMs must be installed in matched pairs of DIMMs. The workstation requires a minimum of one pair of matching DIMMs. Caution – Use proper ESD grounding techniques when handling components. Wear an antistatic wrist strap and use an antistatic mat. Store ESD-sensitive components in antistatic bags before placing them on any surface. 1.Locate the DIMM slots. 2. If you have not already done so, lift the DIMM cooling duct out of the way. Caution – Handle DIMMs only by the edges. Do not touch DIMM components or metal parts. Always wear an antistatic wrist strap when handling DIMMs. 5.Review the recommended DIMM installation and configurations before installing the DIMM. Caution – If you replace a single DIMM, the replaced DIMM must be identical to the one removed. 6.Align the DIMM with the slot. 7. Insert the DIMM into the slot. Using both thumbs, press the DIMM straight down into the DIMM slot until both ejector levers click, locking the DIMM in the DIMM slot Note – The DIMMs must be inserted evenly, straight down along the DIMM slot until locked into place. The DIMM is seated when you hear a click and the DIMM ejector levers are in the vertical position. 8.Repeat Step 6 and Step 7 until all DIMMs are installed. 9. Flip the DIMM cooling duct over toward the front of the chassis, so that the guide rails of the duct are flush with the guide rails of the rear fan bracket. 10.Verify that the DIMM ejector levers are upright, seated, and tight. 11.Reposition the chassis. 12. Install the access panel, power on the system, and verify the component installation
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://support.oracle.com/handbook_private/Systems/SunBlade1500S/components.html#Memory https://support.oracle.com/handbook_private/Systems/SunBlade1500/components.html#Memory
ADDITIONAL COMMENTS: Sun Blade 1500 Service, Diagnostics, and Troubleshooting Manual (Silver): http://docs.oracle.com/cd/E19127-01/blade1500.ws/817-5127-11/817-5127-11.pdf Attachments This solution has no attachment |
||||||||||||||
|