![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1488543.1 : How to Remove and Replace Sun Blade 1500 Red NVRAM:ATR:1488543.1:1
In this Document
Applies to:Sun Blade 1500 Workstation - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. GoalSun Blade 1500 Red, How to Remove and Replace NVRAM Fix DISPATCH INSTRUCTIONS OBTAIN CUSTOMER ACCEPTANCE WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE: Removing the NVRAM 1.Power off the system, then open and position the chassis. Note – NVRAM and the NVRAM connector are keyed. Installing the NVRAM NVRAM installs directly onto the motherboard. There are no additional fasteners or cables. 1.Locate the NVRAM connector. Note – NVRAM and the NVRAM connector are keyed. 3.Press the NVRAM down until snug. 4.Ensure that the NVRAM is tight in its connector. 5.Reposition the chassis, replace the access panel, power on the system, and verify the component installation.
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://support.oracle.com/handbook_private/Systems/SunBlade1500/components.html#IDPROM