In this Document
Goal
Fix
 Removing the SCSI Interface Board
 Installing the SCSI Interface Board


Applies to:

Sun Netra 240 (AC) Server - Version All Versions to All Versions [Release All Releases]
Sun Netra 240 (DC) Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 Netra 240 - How to Remove and Replace Netra 240 SCSI Interface Board

Fix

DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:

Netra 240 product training is desirable but not required, as the part is a CRU

TIME ESTIMATE: 50 mins

TASK COMPLEXITY: 2

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: Faulty SCSI Interface Board

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

The following procedures describe how to remove and install individual PCI cards into the Netra 240 server.

The SCSI interface board houses the two hard drives.

Removing the SCSI Interface Board

1. Power off the server.

2. Grip the bezel at the two finger holds and rotate it down to its open position.

3. Make a note of which drive bay holds each hard drive.

 - You remove the hard drives in the next step. However, you want to install the hard drives back into the same slots that you removed them from at the end of this procedure.

4. Remove the hard drives from the drive bays.

5. Remove the server cover.

6. Open the rotating service module.

7. Ensure that the server is properly grounded.

8. Using a No. 2 Phillips screwdriver, loosen the green captive screw on the top of the SCSI interface board.

9. Detach the bezel cables, the SCSI interface cable, the DVD power/I2C interface ribbon cable, the alarm board cable, and the SCSI interface board power cable from the SCSI interface board.

10. When standing in the front of the server, slide the SCSI interface board to the left and then up to remove it from the rotating service module.

Installing the SCSI Interface Board

1. When standing in the front of the server, place the SCSI interface board into position in the rotating service module.

 - Align the six tabs on the SCSI interface board, then slide the assembly down and to the right to lock into position.

2. Tighten the captive screw to secure the board to the rotating service module.

3. Attach and route the bezel cables, the SCSI interface cable, the DVD power/I2C interface ribbon cable, the alarm board cable, and the SCSI interface board power cable to the SCSI interface board.

4. Close the rotating service module.

5. Install the server cover.

6. Grip the bezel at the two finger holds and rotate it down to its open position

7. Install the hard drives back into the drive bays.

 - Refer to the notes that you took earlier in the procedure to install the hard drives back into the proper bays.

8. Power on the server.


OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:

Bring system back up to a functioning state.
Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:

https://support.oracle.com/handbook_private/Systems/Netra_240_R/components.html

REFERENCE INFORMATION:

Please refer to the Netra 240 Server Service Manual: http://docs.oracle.com/cd/E19102-01/n240.srvr/817-2699-13/817-2699-13.pdf