Goal
Fix
 Removing a DVD Drive:
 Installing a DVD Drive:


Applies to:

Sun Netra 240 (AC) Server - Version All Versions to All Versions [Release All Releases]
Sun Netra 240 (DC) Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

Netra 240 -  How to Remove and Replace a Netra 240 DVD Drive

Fix

DISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:

Netra 240 product training is desirable but not required, as the part is a CRU

TIME ESTIMATE: 30 mins

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: 

PROBLEM OVERVIEW: Faulty DVD Drive


WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.


WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

The following procedures describe how to remove and install the DVD Drive in  the Netra 240 server.

The DVD drive is not hot-swappable. Before you can remove or insert an optional DVD-ROM drive or an optional DVD-RW drive, the server must be powered down and the power input cables disconnected from the rear of the server.

caution icon

Caution - Follow the instructions in this section carefully. The DVD drive contains a laser device. Do not attempt to open the DVD drive enclosure or remove a DVD drive using any procedures other than those contained in this section. If you do, you risk being exposed to radiation.

Removing a DVD Drive:

1. Power off the server.

2. Grip the bezel at the two finger holds and rotate it down to open.

3. Unclip the catches that fasten the DVD drive to the chassis.

4. Pull the DVD drive toward you until it is free of its connectors and out of the server.

Installing a DVD Drive:

1. If the server is powered on, power off the server.

2. If a filler panel is installed, remove the filler panel from the DVD drive slot by pulling it towards you.

Note - Retain the DVD drive slot filler panel for future use.

3. Push the DVD drive firmly into the drive slot until the DVD connector is inserted into the system and the clips engage with the chassis.

4. Close the bezel.

5. Power on the server.

OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO
RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Bring system back up to a functioning state.
Restart software applications per applicable administration guides to resume system operation

PARTS NOTE:

https://support.oracle.com/handbook_private/Systems/Netra_240_R/components.html

REFERENCE INFORMATION:

Please refer to the Netra 240 Server Service Manual: http://docs.oracle.com/cd/E19102-01/n240.srvr/817-2699-13/817-2699-13.pdf