Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1485882.1
Update Date:2012-09-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  1485882.1 :   After disk replacement cell disk name is appearing like "%_duplicate_%" and list griddisk status is showing "importRequired"  


Related Items
  • Oracle Exadata Hardware
  •  
  • Exadata Database Machine V2
  •  
Related Categories
  • PLA-Support>Sun Systems>x64>Engineered Systems HW>SN-x64: EXADATA
  •  




In this Document
Goal
Fix
References


Created from <SR 3-6098129681>

Applies to:

Exadata Database Machine V2 - Version Not Applicable to Not Applicable [Release N/A]
Oracle Exadata Hardware - Version 11.2.1.2.1 to 11.2.3.1.1 [Release 11.2]
Information in this document applies to any platform.

Goal

After disk replacement the cell disk name is appears similar to "%_duplicate_%" and the griddisk status is showing "importRequired".

In the following example disk CD_11_dm01cel02 has been replaced.

List celldisk  shows following status:

name:               CD_11_dm01cel02_duplicate_name
comment:          
creationTime:       2012-08-20T13:51:44+02:00
deviceName:         /dev/sdl
devicePartition:    /dev/sdl
diskType:           HardDisk
errorCount:         0
freeSpace:          0
id:                 d4381735-b68d-462e-b828-4daec84b3f11
interleaving:       none
lun:                0_11
raidLevel:          0
size:               557.859375G
status:             importForceRequired

 

 List griddisk status shows following status:

RECO_CD_11_dm01cel02            importRequired
SYSTEMDG_CD_11_dm01cel02        importRequired
DATA_CD_11_dm01cel02            importRequired

 

 List physicaldisk output is showing status normal:

CellCLI> list physicaldisk 28:11 detail
       name:                   28:11
       deviceId:               29
       diskType:               HardDisk
       enclosureDeviceId:      28
       errMediaCount:          0
       errOtherCount:          0
       foreignState:           false
       luns:                   0_11
       makeModel:              "SEAGATE ST360057SSUN600G"
       physicalFirmware:       0A25
       physicalInsertTime:     2012-08-20T10:53:30+02:00
       physicalInterface:      sas
       physicalSerial:         E0Z09R
       physicalSize:           558.9109999993816G
       slotNumber:             11
       status:                 normal

 

 Running import with force option is failing with following error:

CellCLI> import celldisk CD_11_dm01cel02 force

CELL-04560: Cannot complete import of cell disk CD_11_dm01cel02.  
Received Error: CELL-02525: Unknown cell disk: CD_11_dm01cel02
Cell disks not imported: Celldisk: CD_11_dm01cel02

 

Fix

 1. Drop the cell disk:

cellcli> drop celldisk <CelldiskName>  force

 
 2. Now create celldisk and griddisk manually using following note

Steps to manually create cell / grid disks on Exadata V2 if auto-create fails during disk replacement <Document: 1281395.1>

References

<NOTE:1281395.1> - Steps to manually create cell/grid disks on Exadata V2 if auto-create fails during disk replacement