![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1485615.1 : 9840/T10000 - Number of Initiators/Channel Paths for Each Drive Model
In this Document
Applies to:Sun StorageTek 9840C Tape Drive - Version Not Applicable and laterSun StorageTek 9840D Tape Drive - Version Not Applicable and later Sun StorageTek T10000B Tape Drive - Version Not Applicable and later Sun StorageTek T10000A Tape Drive - Version Not Applicable and later StorageTek T10000C Tape Drive - Version Not Applicable and later Information in this document applies to any platform. Goal9840/T10000 - Number of Initiators/Channel Paths for Each Drive Model FixNumber of initiators/channel paths for each drive model listed below. 9840C FC 256, 9840C FICON 256, 9840C ESCON 128 9840D FC 256, 9840D FICON 256, 9840D ESCON 128 T10000A FC 256 per port == total 512, T10000A FICON 512 any combination total T10000B FC 256 per port == total 512, T10000B FICON 512 any combination total T10000C FC 256 per port == total 512, T10000C FICON 512 any combination total Note: The T10kx drives can only have 256 per port (for a total connection capacity of 512), where as the Ficon drives can have a total of 512 in any combination over the 2 ports. Provided by Rob Wilber Attachments This solution has no attachment |
||||||||||||||
|