Solution Type  Technical Instruction Sure

Solution  1485615.1 :   9840/T10000 - Number of Initiators/Channel Paths for Each Drive Model  


Related Items
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek 9840D Tape Drive
  •  
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
  • Sun StorageTek 9840C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Goal
Fix


Applies to:

Sun StorageTek 9840C Tape Drive - Version Not Applicable and later
Sun StorageTek 9840D Tape Drive - Version Not Applicable and later
Sun StorageTek T10000B Tape Drive - Version Not Applicable and later
Sun StorageTek T10000A Tape Drive - Version Not Applicable and later
StorageTek T10000C Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.

Goal

 9840/T10000 - Number of Initiators/Channel Paths for Each Drive Model

Fix

Number of initiators/channel paths for each drive model listed below.

9840C FC 256, 9840C FICON 256, 9840C ESCON 128

9840D FC 256, 9840D FICON 256, 9840D ESCON 128

T10000A FC 256 per port == total 512, T10000A FICON 512 any combination total

T10000B FC 256 per port == total 512, T10000B FICON 512 any combination total

T10000C FC 256 per port == total 512, T10000C FICON 512 any combination total

Note:

The T10kx drives can only have 256 per port (for a total connection capacity of 512), where as the Ficon drives can have a total of 512 in any combination over the 2 ports.