Goal
Fix


Applies to:

Sun StorageTek L700 Tape Library - Version Not Applicable and later
Sun StorageTek L700e Tape Library - Version Not Applicable and later
Sun StorageTek L1400 Tape Library - Version Not Applicable and later
Sun StorageTek L180 Tape Library - Version Not Applicable and later
Information in this document applies to any platform.

Goal

L180/L700/L1400 - Information on MIBs supported via SNMP Messages 

Fix

The MIB information for STK L-Series libraries can be found here:

http://docs.oracle.com/cd/E19828-01/index.html
L1400M Interface Control Module User Guide 96231

The L180/700/1400M Interface Control Module (control module) supports two Management Information Bases (MIBs) for management using SNMP: the Fibre Alliance (FA) MIB and the Crossroads Enterprise MIB. A Management
Information Base contains complete descriptions of the different types of information that can be exchanged between the control module and a management application using SNMP (Simple Network Management Protocol). The FA MIB is an Fibre Channel industry standard MIB that provides support for link status, event logging, traps and other information in conformance with the FA MIB 2.2 guidelines. The Crossroads Enterprise MIB allows access to all configuration information stored in the control module.

Remember that the library needs to have the Personality Module to work with SNMP:

L Series Library - Will SNMP Work Wthout a Personality Module? (Doc ID 1015564.1)