Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1473799.1
Update Date:2012-09-13
Keywords:

Solution Type  Technical Instruction Sure

Solution  1473799.1 :   SL150 - How to do a Factory Reset on the StorageTek SL150 Modular Tape Library  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Goal
Fix


Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 How to do a Factory Reset on the StorageTek SL150 Modular Tape Library

Fix

 In order to do a factory reset on the SL150 library you will need 2 people.

 

One person will need to stand at the front of the SL150 library and one person will need to stand at the rear of the SL150 library.

Note: The SL150 library will need to be in a powered up/booted up state (the Linux kernel boot has to be complete).

The person at the front of the library will need to push and hold the locate button on the front of the SL150 library and then the person at the rear of the library will need to push and hold the locate button on the rear of the SL150 library.

The locate buttons will start to flash slowly, continue to hold in both of the locate bottons until the locate buttons start to flash quickly.

Once the locate buttons flash at a fast rate both buttons can be released and the library will do a factory reset and will reinitialize.

You now will have to go through the Initial Config Wizard in order to setup the SL150 library.

SL150 - What is the StorageTek SL150 Modular Tape Library Default Password for the Initial Config Wizard (Doc ID 1473831.1)


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback